Combustion Chamber Replacement for 66/68 Series Boilers Zoom

Combustion Chamber Replacement for 66/68 Series Boilers

SKU:386-500-085

Brand: Weil Mclain

Weil Mclain
Qty Price
$104.95
/ each
In Stock! Ships in 24-48 Hours
(4 Available)

Specs

Accessory For: 68 Boilers

Description for Weil Mclain 386-500-085

Weil McLain combustion chamber replacement for 66/68 series boiler models. Includes:

  • Insulation Blanket
  • Back Refractory
  • Front Refractory,
  • 4 oz. Water Glass
  • Installation Instructions

Combustion Chamber Replacement for 66/68 Series Boilers

REVIEW SNAPSHOT®

by PowerReviews
Weil MclainCombustion Chamber Replacement for 66/68 Series Boilers
 
4.8

(based on 8 reviews)

Ratings Distribution

  • 5 Stars

     

    (6)

  • 4 Stars

     

    (2)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (0)

100%

of respondents would recommend this to a friend.

Pros

    Cons

      Best Uses

          • Primary use:
          • Personal (8)

        Reviewed by 8 customers

        Sort by

        Displaying reviews 1-8

        Back to top

         
        5.0

        pleased

        By mike

        from missoula mt

        Verified Buyer

        Pros

          Cons

            Best Uses

              Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

              The speed at which you shipped and I received my product was impressive I will be able to refurbish my boiler back to new at a very reasonable price thanks to you pex supply.

              • Primary use:
              • Personal
               
              5.0

              Great Part! Great fast service!

              By Les the Builder

              from Liberty, PA.

              Verified Buyer

              Pros

                Cons

                  Best Uses

                    Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

                    I got what I expected and was very satisfied!

                    • Primary use:
                    • Personal
                     
                    5.0

                    perfect fit

                    By Garfield John

                    from Garfield N J

                    Verified Buyer

                    Pros

                      Cons

                        Best Uses

                          Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

                          came with good directions@great fit,eazy to install

                          • Primary use:
                          • Personal
                           
                          5.0

                          Installation was the easy part

                          By Half-Handy

                          from New England

                          Verified Buyer

                          Pros

                            Cons

                              Best Uses

                                Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

                                Installing the liner went quickly. As others have suggested, check the condition of the door insulating blanket (behind the door refractory) since it does not come with the combustion chamber kit. Order both if you are not sure. Mine was OK after 20 years. Prep is very important so make sure you have the right brushes and a sacrificial shop vac. Clean everything before starting to install the new liner! My vac was so dirty after the job that I threw it away. The firebox walls need to be very clean for the new liner to stick properly so get them as clean as possible. And carefully follow the "curing" procedure... slowly bring the furnace up to temp in short bursts per the directions.

                                • Primary use:
                                • Personal
                                 
                                4.0

                                straightforward installation

                                By randy1kenobi

                                from Hampton, NJ

                                Verified Buyer

                                Pros

                                  Cons

                                    Best Uses

                                      Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

                                      Installing this kit was the easier part of the job. Removing the front of the combustion chamber was a bit more of a challenge. Had to replace 2 broken studs. Luckily my local auto parts store had ones that fit. As someone else pointed out, make sure to also order the Cerablanket Front Access Plate Insulation (Part #591-221-054). It will likely also need to be replaced and only costs an additional $5. Also, the rope combustion chamber cover gasket has double sided tape which comes with one side stuck to the rope. It is hard to remove the backing without pulling the tape off the rope, but it can be done with some patience. This tape holds the rope gasket to the cover for re-installation (which is also a little tricky) but I managed get it all together and it seems to be working fine.

                                       
                                      5.0

                                      combustion liner

                                      By AA

                                      from Nazareth PA

                                      Verified Buyer

                                      Pros

                                        Cons

                                          Best Uses

                                            Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

                                            very easy to install

                                            • Primary use:
                                            • Personal
                                             
                                            4.0

                                            A relatively easy job

                                            By wildintrovert

                                            from Reedsville, PA

                                            Verified Buyer

                                            Pros

                                              Cons

                                                Best Uses

                                                  Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

                                                  My combustion chamber liner had disintegrated and I decided to save money and do the job myself. Although I tried to be very careful I broke off a bolt that secured the burner flange which I had to drill out and tap. I also had to drill and split one of the four nuts that secured the cast iron door as it was rusted fast. I would recommend running a die over the threads of the four studs and coating with anti-seize compound before reassembly in case you would have to do this job in the future. Wire brush burner flange bolts and anti-seize them too. I thoroughly cleaned and wirebrushed the chamber interior. Installation of liner was easy although I wasn't sure how evenly the waterglass was supposed to be spread over chamber bottom as the directions didn't specify. Also, the adhesive on the high-temp rope gasket was totally dried out and wouldn't stick to the door so I used contact cement to hold it in place until door was bolted back on. It helps to thorougly clean out the gasket groove in the door before applying the rope. I'm sure I saved a lot of money by doing the job myself because it was rather time consuming partly due to rusted nuts and bolts, and I figured I did a more careful, thorough job than the furnace guys would have done. My ceroblanket insulation that is sandwiched between outer chamber liner and door was in ruins so play it safe and order this when ordering the liner kit. You can't replace the door liner if you need a new ceroblanket and it costs only about 5 bucks.

                                                  • Primary use:
                                                  • Personal
                                                   
                                                  5.0

                                                  Great fit - easy installation

                                                  By Tom

                                                  from Boston

                                                  Verified Buyer

                                                  Pros

                                                    Cons

                                                      Best Uses

                                                        Comments about Combustion Chamber Replacement for 66/68 Series Boilers:

                                                        Came with all the necessary parts, fit well.