Application: Heating
Type: Radiant Heat Package
Coverage (Sq Ft.): 250
Fitting System Compatibility: PEX Compression
Tubing Compatibility: PEX
PEX Size: 5/16"
Tubing Type: Oxygen Barrier
Length (Feet): 500'
Number of Outlets: 2

Description for Uponor (Wirsbo) QUIK250

This 250 sq. ft. Quik Trak radiant heat package contains the following products: (Please note that the numbers in parentheses represent the quantity included in the package).

Quik Trak

Tubing Fittings Accessories **NOTE: This package does NOT include pumps, controls or valves that may be necessary to complete the installation.

Quik Trak Radiant Heat Package - 250 sq ft

Q&A: Ask the Questions, share answers

Do you have questions about this product?

get answers from real customers and in-house experts with AnswerBox.

7 Questions | 7 Answers
Displaying questions 1-7
  • Quik Trak Radiant Heat Package - 250 sq ft

    Q:

    Screws are not included? What type of screw do you recommend?
    Asked on 6/13/2011 by georgeharrison from lanse, michigan

    1 answer

  • Quik Trak Radiant Heat Package - 250 sq ft

    Q:

    I have a room that is 15'x 18', heated by 30 feet of copper fin tube. Will the 250' package be enough to replace that?
    Asked on 6/13/2011 by georgeharrison from lanse, michigan

    1 answer

    • CUSTOMER CARE

      A:

      The room is 270 square feet. The package covers 250 square feet worth of floor space.

      Answered on 6/21/2011 by PexSupply Staff from NY
  • Quik Trak Radiant Heat Package - 250 sq ft

    Q:

    What underlayment is necessary over Quik Trak if you are laying carpet?
    Asked on 6/11/2011 by georgeharrison from lanse, michigan

    1 answer

    • CUSTOMER CARE

      A:

      You can either place the carpet directly on top of the Quik Trak, or put down a layer of plywood.

      Answered on 6/13/2011 by PexSupply Staff from NY
  • Quik Trak Radiant Heat Package - 250 sq ft

    Q:

    I have a un-level floor and want to install quik trak with tile.. can I pour a self-leveler over quik trak than install tile as normal?.. and if I can't pour it over it why?
    Asked on 3/16/2011 by Anonymous

    1 answer

    • CUSTOMER CARE

      A:

      You can use the self-leveler, but you would need to place a cement board between the Quik Trak and the self-leveler. It is not recommended to put cement directly onto the Quik Trak because the moisture could harm the wood.

      Answered on 3/17/2011 by PexSupply Staff from NY
  • Quik Trak Radiant Heat Package - 250 sq ft

    Q:

    How thick does the durock have to be that is laid over the quik trak system so I can lay tile? Is there such a thing as too thick?
    Asked on 1/11/2011 by Bob from Buffalo, NY

    1 answer

    • CUSTOMER CARE

      A:

      The manufacturer recommends that you use either 3/8" or 1/2" of durock.

      Answered on 1/20/2011 by PexSupply Staff from NY
  • Quik Trak Radiant Heat Package - 250 sq ft

    Q:

    can laminate flooring be placed directley on top.
    Asked on 10/25/2010 by kevin from new york

    1 answer

    • CUSTOMER CARE

      A:

      Yes, you can place laminate flooring directly on top of the Quik Trak unless glue is being used to put the laminate flooring down. If glue is being used a piece of plywood has to go in between the trak and the flooring.

      Answered on 10/26/2010 by PexSupply Staff from NY
  • Quik Trak Radiant Heat Package - 250 sq ft

    Q:

    I'd like to buy this product but need to calculate the heat loss in my room before doing so. How do I calculate the heat loss in my room??
    Asked on 9/22/2010 by Scott from Madison, WI

    1 answer

    • CUSTOMER CARE

      A:

      You can contact a certified installer to perform a heat loss calculation on your room. Alternatively, you can do it yourself using a guide such as the H-22 heat loss guide by the Hydronics Institute Division of GAMA.

      Answered on 9/24/2010 by PexSupply Staff from NY