Apply to be a TradeMaster!
Filter menu expanded

Filters

2 items
Reset

SORT

Product Availability
–

Show In Stock Only (2)

Product Type
–

Humidifier (2)

Capacity (Gallons/day)
–

19.2 (1)
21.3 (1)

Voltage
–

120v (1)
24V (1)

Review Score
–

(2)

Price Range
–

$200 to $300 (1)
$300 to $400 (1)

General Aire Legacy Humidifiers

Help Face
Need a little help?
2 items
Grid
List
Compare
Product Image of 1137 21.3 GPD Drain Type Fan Power Humidifier (120v)
1137 21.3 GPD Drain Type Fan Power Humidifier (120v)
SKU: 5137
General Aire
SKU: 5137
Brand: General Aire
(19)
$329.19 each
In Stock
Get 51 by Mon, Nov 23
In Stock
Get 51 by Mon, Nov 23
Compare
Product Image of 1042LH By-Pass Drain Type Humidifier (24v)
1042LH By-Pass Drain Type Humidifier (24v)
SKU: 5144
General Aire
SKU: 5144
Brand: General Aire
(21)
$208.99 each
In Stock
Get 42 by Mon, Nov 23
In Stock
Get 42 by Mon, Nov 23
Resources
FAQs, Manuals & Videos
Articles
More About General Aire Legacy Humidifiers

General Aire Legacy Humidifiers are evaporative bypass humidifiers built to mount on either side of a forced-air furnace and add moisture to whole-house air as it passes through the system. The Legacy line covers homes up to 4,200 square feet, giving installers a single family of units to spec across a wide range of house sizes rather than switching brands between small and large jobs. Because the design is bypass evaporative rather than steam, the unit draws conditioned air through a water panel using the furnace blower's own airflow, which keeps installation simple and keeps ongoing operating demands low. Some models in the line add a dedicated fan to push air through the water panel independent of furnace blower speed, which matters on systems where blower runtime doesn't line up well with humidification needs. For HVAC contractors handling seasonal comfort calls, the Legacy Series gives a straightforward, furnace-mounted option that fits standard bypass or fan-powered install practices without introducing an unfamiliar humidification technology into the job.

Subcategories

  • Bypass Evaporative Humidifiers: Bypass models use the furnace blower's static pressure to pull warm air through a water-saturated evaporator pad, with no separate fan required. HVAC installers use these on standard forced-air systems where duct static pressure is sufficient to move air through the bypass damper. They're the simplest Legacy Series install since there's one less powered component to wire.
  • Fan-Powered Evaporative Humidifiers: Fan-powered models, such as the Model 1137, add an integral fan that pushes air through the evaporator pad instead of relying solely on the furnace blower. Installers spec these on homes where the furnace doesn't run long enough on its own to keep up with humidity demand. The added fan lets the unit maintain output even during short furnace cycles.
  • Manual Control Models: Manual control units pair with a wall-mounted humidistat that the homeowner or technician sets to a target humidity level. These suit straightforward installs where automatic outdoor-temperature compensation isn't part of the scope. Contractors often choose manual control for budget-conscious replacement jobs.

Buying Guide

Match the model to the square footage of the home first, since General Aire Legacy Humidifiers are sized by coverage area up to 4,200 square feet and an undersized unit won't keep pace with a larger structure through a full heating season. Next, decide between a bypass and a fan-powered model based on furnace runtime. If the furnace cycles briefly and often, a fan-powered model keeps moisture output consistent because it isn't limited to blower-on periods; if the furnace runs longer cycles, a simpler bypass unit is usually enough and has one fewer powered part to service later. Mounting side matters too: confirm there's clear duct access on whichever side of the furnace the installation calls for, since Legacy Series humidifiers are designed to mount on either side. Water supply and drain routing should be checked at the same time, since every evaporative model needs both a cold water line to the pad and a drain path for bypass water. For control, a manual humidistat covers most residential jobs, while installs with strict comfort targets may call for tighter control logic. Whichever model gets specified, plan the seasonal maintenance visit into the job, since the evaporator pad is a wear item that needs periodic replacement to keep the unit performing at rated capacity.

Frequently Asked Questions

What size home can a General Aire Legacy Humidifier handle?

The Legacy Series covers homes up to 4,200 square feet, with different models sized for different points in that range. Confirm the specific model's rated coverage against the home's square footage before installing.

What's the difference between the bypass and fan-powered Legacy models?

Bypass models rely on the furnace blower to push air through the evaporator pad, while fan-powered models like the 1137 include a dedicated fan for that job. Fan-powered units keep output steady even when the furnace only runs in short bursts.

Which side of the furnace does a Legacy Humidifier mount on?

Legacy Series humidifiers are built to mount on either side of the furnace, so installers can choose whichever side has usable duct access. That flexibility is one reason the line works across varied duct layouts.

Does a General Aire Legacy Humidifier need a drain line?

Yes, evaporative bypass humidifiers need both a water supply line to saturate the evaporator pad and a drain path for water that passes through. Plan for both connections during rough-in, not just the supply side.

How is a Legacy Humidifier controlled?

Manual control models pair with a wall-mounted humidistat that sets a target indoor humidity level. That control approach fits most standard residential installs without added wiring complexity.

Didn't find what you're looking for? 
Let us know
.