Apply to be a TradeMaster!
Filter menu expanded

Filters

10 items
Reset

SORT

Product Availability
–

Show In Stock Only (3)

Used With
–

All Res. HW Boilers (1)
IN3-IN12 Boilers (1)
MMII Boilers (1)
MMII4-MMII5 Boilers (4)

Review Score
–

(3)

Price Range
–

$20 to $25 (1)
$35 to $40 (1)
$60 to $70 (2)
$70 to $80 (1)
$80 to $90 (1)
$100 to $200 (4)

Minuteman II Boiler Parts

Help Face
Need a little help?
FIND PARTS FOR YOUR UNIT
10 items
Grid
List
Compare
Product Image of Flame Roll-Out Switch/FRS Bracket Assembly for MMII4-MMII5 Boilers, 6016060
$24.19 each
In Stock
Get 7 by Mon, Nov 23
In Stock
Get 7 by Mon, Nov 23
Compare
Product Image of Pressure Relief Valve, 30 PSI for All Res. HW Boilers, 81660319
$66.16 each
In Stock
Get 6 by Mon, Nov 23
In Stock
Get 6 by Mon, Nov 23
Compare
Product Image of Limit Switch with Manual Reset 200F, 6016066
$37.78 each
In Stock
Get 9 by Mon, Nov 23
In Stock
Get 9 by Mon, Nov 23
Compare
Product Image of Connector, Vent-Blower 3" SS w/ Gasket MMII, 5/6 SEC PV'S & SP, 8116307
$156.45 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Differential Air Pressure Switch for RV5/RV6, MMII4-70/MMII4-105 Boilers, 60160885
$113.41 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Flue Monitor Switch for MMII4-MMII5 Boilers, 80160622
$86.90 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of HW 394803-2 Electronic Ignition Sensor Cable for IN3-IN12, MMII4-MMII5 Boilers, 8236121
$64.72 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of DPST Relay for MMII4-MMII5 Boilers, 80160096
$76.07 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Tank Aquastat for MMII4-MMII5 Boilers, 80160499
$190.37 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Differential Air Pressure Switch for RV7, MMII5-105/MMII5-140 Boilers, 60160887
$100.24 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Resources
FAQs, Manuals & Videos
Articles
More About Minuteman II Boiler Parts

Minuteman II boiler parts keep Burnham's Minuteman II boilers running once original equipment components wear down or fail. Burnham, part of U.S. Boiler Company's product lineup, built the Minuteman II as part of its residential and light-commercial boiler offerings, and units installed years ago are still in service in homes and small buildings today. Replacement parts for this line cover the components a technician typically needs during a service call, including ignition components, valves, circulator pumps, and control boards. Sourcing the correct part for a Minuteman II model keeps an older boiler operating safely without a long wait for a special order.

Subcategories

  • Ignition & Flame Sensing Components: Ignition and flame sensing components get a boiler's burner lit and confirm that flame is present once it's running, and these parts wear out from repeated heat cycling over years of service. A technician troubleshooting a boiler that won't ignite or shuts down mid-cycle often checks these components before moving to larger assemblies. Replacing a worn ignition part is usually a smaller repair than replacing the burner assembly it serves. Keeping a few common ignition parts on the truck saves a second trip on straightforward service calls.
  • Circulator Pumps: Circulator pumps move heated water from the boiler out through the system's piping to radiators, baseboard, or radiant loops. A pump that's failed or losing efficiency often shows up as a system that won't heat evenly or a boiler that short-cycles. Matching a replacement pump's flow and head rating to the original keeps the system's heat distribution working the way it was designed. Circulator pumps are one of the more commonly replaced components on an aging boiler system, since they run continuously during a heating season.
  • Controls & Circuit Boards: Control boards manage a boiler's ignition sequence, safety limits, and circulator operation, coordinating the parts that keep the unit running safely. A board that's failed can cause anything from a boiler that won't start to one that ignores a safety limit switch, so diagnosing the fault correctly before ordering a replacement board avoids an unnecessary part swap. Boards for an older model line like Minuteman II may need to be sourced through a distributor rather than found on a shelf locally. Keeping the original board's part number on hand when ordering helps confirm compatibility with the rest of the boiler's wiring.
  • Valves & Relief Valves: Boilers use a mix of valves, including pressure relief valves, to control water flow and protect the system from overpressure situations. A relief valve that's stuck or leaking is a safety concern that shouldn't wait for a convenient time to address. Replacement valves need to match the original's pressure rating and pipe connection size to fit correctly into the existing piping. Testing a relief valve periodically catches a valve that's started sticking before it becomes a bigger problem.
  • Buying Guide

    Start by identifying the specific Minuteman II model number stamped on the boiler's rating plate, since Burnham's boiler lines often organize part numbers by tonnage or input size rather than one universal part across every unit. A model number mismatch is one of the most common reasons a replacement part doesn't fit even when it looks correct at a glance.

    Next, decide whether the failed component is worth chasing down individually or whether a related assembly should be replaced together. Minuteman II boiler parts for an older, discontinued model line can take longer to source than parts for a current production boiler, so ordering a broader repair kit when a technician is already on site sometimes makes more sense than a return trip for one missed part.

    Safety-related components, including relief valves, limit switches, and ignition parts, deserve extra attention to part number accuracy since these protect against overpressure and combustion hazards rather than just comfort issues. Circulator pumps and control boards, by contrast, mostly affect performance and can sometimes accept a compatible cross-reference part rather than requiring an exact original manufacturer match, depending on what the boiler's wiring and piping will accept.

    Finally, keep records of what was replaced and when. An aging boiler line like Minuteman II benefits from a maintenance history that helps predict which component is likely to fail next during future service calls.

    Frequently Asked Questions

    Where is the model number found on a Minuteman II boiler?

    The model number is stamped on the boiler's rating plate, typically mounted on the jacket near the front or side of the unit. Confirming this number before ordering parts is the most reliable way to avoid a part that looks right but doesn't fit the specific unit installed.

    Are Minuteman II boiler parts still available since the model isn't in current production?

    Parts for older, discontinued boiler lines like Minuteman II can take longer to source than parts for a currently produced model, but they typically remain available through distributors carrying the manufacturer's parts catalog. Planning ahead for parts that may need a special order helps avoid extended downtime on an older unit.

    Can a generic circulator pump replace the original Minuteman II pump?

    A replacement circulator needs to match the original's flow rate and head rating to keep the system's heat distribution working as designed, whether or not it's the exact original brand. Confirming the pump's specifications against the original before ordering matters more than matching manufacturer names alone.

    What should be checked first when a Minuteman II boiler won't ignite?

    Ignition components and flame sensing parts are the most common starting point for an ignition failure, since these wear out from repeated heat cycling over years of service. Ruling these out before assuming a bigger control or valve issue often resolves the call faster.

    How often should a relief valve on an older boiler like Minuteman II be tested?

    Relief valves should be checked periodically as part of routine boiler maintenance, since a valve that's started sticking is a safety concern rather than just a performance issue. Catching a sticking valve during a scheduled visit avoids waiting for it to fail during operation.

Didn't find what you're looking for? 
Let us know
.