Apply to be a TradeMaster!
Filter menu expanded

Filters

5 items
Reset

SORT

Product Availability
–

Show In Stock Only (2)

Tank Volume
–

4.4 Gallons (1)
14 Gallons (1)
20 Gallons (2)
7.4 Gallons (1)

Review Score
–

(2)

WELL-X-TROL Pump Stand & Space Saver Tanks

Help Face
Need a little help?
5 items
Grid
List
Compare
Product Image of WX-102-PS (141PR373), 4.4 Gal WELL-X-TROL Well Tank (Pump Stand)
$397.09 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of WX-202H (144S236), 20 Gal WELL-X-TROL Well Tank (Space Saver)
$540.11 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of WX-200PS (143PR277), 14 Gal WELL-X-TROL Well Tank (Pump Stand)
$612.15 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of WX-110-PS, 7.4 Gal WELL-X-TROL Well Tank (Pump Stand)
$385.60 each
Backorder
Get it by Wed, Dec 16 - Wed, Dec 23
Backorder
Get it by Wed, Dec 16 - Wed, Dec 23
Compare
Product Image of WX-202-PS, 20 Gal WELL-X-TROL Well Tank (Pump Stand)
$1,181.90 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Videos
Articles
More About WELL-X-TROL Pump Stand & Space Saver Tanks

WELL-X-TROL pump stand and space saver tanks are pre-pressurized well tanks built by Amtrol for water systems where floor space or pump placement is limited. A pump stand tank doubles as a mounting base for a submersible or jet pump, combining the pressure tank and pump support into one footprint, while a space saver tank uses a narrower, taller profile to fit tight mechanical rooms and closets. Both styles use a sealed diaphragm or bladder to separate the water chamber from a precharged air cushion, reducing pump cycling and extending pump life compared to a plain steel tank. Contractors specify these tanks on well water systems, boosted city water setups, and any installation where a standard-diameter tank will not clear a doorway or crawlspace opening. Correct precharge pressure, set to match the pump's cut-in setting, keeps the diaphragm working through its full stroke and prevents premature waterlogging.

Subcategories

  • Pump Stand Tanks: Pump stand tanks feature a flat, reinforced top plate designed to support the weight of a submersible or shallow well jet pump directly above the tank, eliminating the need for a separate pump mounting bracket or stand. Installers use them in tight well houses, pits, and utility closets where floor space runs short. The tank's base doubles as the pump's operating platform, so it needs to be rated for the specific pump's mounting bolt pattern and weight. The design keeps piping runs short and simplifies servicing since the pump sits at a consistent, accessible height.
  • Space Saver Tanks: Space saver tanks use a taller, narrower shell than standard well tanks, letting them fit through standard doorways and into slim mechanical closets without sacrificing usable air-water volume. They are common in finished basements, condo utility rooms, and retrofit jobs where an oversized older tank needs to be swapped for one that clears existing framing. The narrower diameter means these tanks typically mount with a floor stand or wall bracket rather than sitting freestanding. Contractors reach for this style whenever ceiling height or doorway width, not tank capacity, is the limiting factor.
  • Tank Fittings & Accessories: Fittings and accessories for these tanks include tank tees, pressure gauges, air volume control valves, and mounting brackets that complete a working well system around the tank itself. A tank tee combines the pressure switch, relief valve, and gauge ports into a single fitting threaded into the tank's system connection, cutting down on pipe joints and potential leak points. Replacement bladders and air valves let an existing tank be serviced rather than replaced outright when the diaphragm fails. Matching the fitting size to the tank's threaded connection is the main compatibility point to check before ordering.
  • Buying Guide

    Choosing between a WELL-X-TROL pump stand tank and a space saver tank starts with the physical constraints of the install location rather than the water system's demand alone. Measure the available floor footprint, ceiling height, and doorway width first, since a tank that will not fit through the access point is not a usable option regardless of its capacity rating. For a submersible pump installation where floor space is scarce, a pump stand tank lets the tank and pump share one location instead of requiring separate mounting hardware. For narrow mechanical rooms or retrofit jobs replacing an older, bulkier tank, a space saver model trades tank diameter for height while keeping a comparable drawdown volume. Drawdown capacity, the amount of usable water the tank delivers between pump cycles, should be sized to the well pump's flow rate and the household's peak demand; an undersized tank causes the pump to short-cycle, which shortens motor life. WELL-X-TROL Pump Stand & Space Saver Tanks both rely on a correctly set air precharge, typically matched a few psi below the pump's cut-in pressure, to keep the internal diaphragm working through its full range. Confirm the tank's maximum working pressure against the system's actual operating pressure, and check the system connection thread size against existing piping before ordering, since retrofitting a different thread size adds an extra fitting to the job.

    Frequently Asked Questions

    What is the difference between a pump stand tank and a space saver tank?

    A pump stand tank has a reinforced top designed to support a submersible or jet pump directly above it, combining the pump mount and pressure tank in one unit. A space saver tank is simply built taller and narrower than a standard tank to fit through tight doorways or closets, with no pump-mounting function built in.

    How do I know what size tank my well system needs?

    Tank size depends on the pump's flow rate in gallons per minute and the household's peak water demand, not just the number of fixtures in the building. A plumber or well contractor typically calculates required drawdown capacity from the pump's specifications before recommending a tank size.

    Why does a well tank need a precharge of air?

    The air precharge cushions the water chamber inside the tank, letting the tank store water under pressure without the pump running constantly. Setting the precharge correctly, usually a few psi below the pump's cut-in setting, keeps the internal diaphragm working through its intended range and prevents early failure.

    Can a pump stand tank be installed without a pump mounted on top?

    Yes, a pump stand tank can be plumbed and pressurized like any other well tank even if no pump sits on the mounting plate. The reinforced top is a feature for installations that need it, not a requirement for the tank to function.

    What causes a well tank to become waterlogged?

    Waterlogging happens when the internal diaphragm or bladder fails and the air precharge mixes with or is displaced by water, causing the pump to cycle rapidly. Replacing the tank or, on serviceable models, the internal bladder and air valve restores normal operation.

Didn't find what you're looking for? 
Let us know
.