WELL-X-TROL underground tanks are pre-pressurized well tanks built for burial near a well system rather than installation inside a building. Amtrol, the manufacturer behind the WELL-X-TROL line, invented the first pre-pressurized well tank in 1963, following its 1954 introduction of the EXTROL expansion tank for hydronic heating systems, according to the company's own history. A pre-pressurized well tank reduces how often a well pump cycles on and off by storing a reserve of pressurized water between pump runs, and an underground model does this while sitting below grade near the wellhead instead of inside a pump house or basement. Installers choose an underground tank specifically when the well setup doesn't have indoor space for a standard tank, or when local site conditions call for burying the tank near the well itself. Matching tank capacity to the well pump's draw-down needs keeps the pump cycling within a healthy range and extends pump life.
Subcategories
Buying Guide
Choosing a WELL-X-TROL underground tank starts with confirming that burial near the wellhead is the right approach for the site, since an underground tank is chosen specifically when there's no indoor space available or when site conditions call for a buried installation rather than a tank inside a pump house or basement. Capacity sizing comes next, and it depends on the well pump's draw-down rate and the household or facility's peak water demand, since an undersized tank causes the pump to cycle on and off more frequently than it should, shortening pump life over time. Amtrol's WELL-X-TROL line traces back to the company's 1963 invention of the first pre-pressurized well tank, and the underground models apply that same pre-pressurized diaphragm principle in a tank built for below-grade installation. Pressure rating and pre-charge need to be set to match the well system's operating pressure before burial, since adjusting pre-charge after the tank is in the ground is far more difficult than checking it beforehand. Access planning deserves attention during installation too: leaving a way to reach pressure gauges or fittings without full excavation saves considerable time on future service calls. Contractors should also confirm the tank's corrosion protection and burial depth rating match the site's soil and groundwater conditions, since underground tanks face exposure that indoor models don't, and following Amtrol's installation guidance for underground models protects both the tank and the warranty coverage that comes with it.
Frequently Asked Questions
What's the difference between a WELL-X-TROL underground tank and a standard indoor model?
Both use the same pre-pressurized diaphragm design, but underground models are built and rated for burial near the wellhead, while standard models install inside a pump house, basement, or utility space.
Why would a well system need an underground tank instead of an indoor one?
An underground tank is typically chosen when there's no indoor space available for a standard tank or when site conditions call for burying the tank near the well itself.
Who invented the pre-pressurized well tank?
Amtrol, the manufacturer of the WELL-X-TROL line, invented the first pre-pressurized well tank in 1963, following its 1954 introduction of the EXTROL expansion tank for hydronic systems.
How is an underground well tank sized?
Sizing is based on the well pump's draw-down rate and the property's peak water demand, since an undersized tank causes the pump to cycle more frequently and shortens pump life.
Can the pre-charge on a buried tank be adjusted after installation?
Technically yes if access fittings are reachable, but it's far more practical to confirm and set the pre-charge before burial, since adjusting it afterward requires reaching the tank underground.