Apply to be a TradeMaster!
Filter menu expanded

Filters

59 items
Reset

SORT

Product Availability
–

Show In Stock Only (56)

Application
–

Coiled Bulb Temperature (3)
Commercial (1)
Cool Only (3)
Cooling (1)
Dual Fuel Changeover (1)
Fan Coil (1)
Fluid Cutout (1)
Heat Only (1)
Hot Water (1)
Hot Water Cutout (1)

Max Temp (F)
–

50°F (1)
70°F (1)
80°F (2)
85°F (1)
95°F (1)
100°F (7)
110°F (2)
150°F (2)
225°F (1)
240°F (8)

Min Temp (F)
–

-30°F (7)
0°F (1)
20°F (2)
25°F (1)
30°F (5)
35°F (1)
40°F (1)
45°F (1)
90°F (1)
100°F (8)

Voltage
–

120v (10)
240v (9)
208V (6)
24/277v (1)

Review Score
–

(12)
(1)

Price Range
–

$90 to $100 (2)
$100 to $200 (44)
$200 to $300 (5)
$300 to $400 (5)
$400 to $500 (1)
$700 to $800 (2)

A19 Series Utility Thermostats

Help Face
Need a little help?
59 items
Grid
List
Compare
Product Image of Strap On, 100/240f, 10f Dif, Spdt, A19DAC-12
$130.49 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 20/80f 6'cap 3.5/14 Adjustable Differential Spdt, A19ABC-2
$168.11 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of Coiled Bulb Temp Control, -35/40c, A19BBC-4
$183.75 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 0/70f 5' Spdt 12/40f Adjustable Differential, A19ZBC-6
$387.21 each
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Compare
Product Image of 30/80f 6'cap.open-low/ Tank Adapter, A19ZBA-1
$349.88 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 50-200f 20' Adj Dif 6-24 Spdt, A19ABC-44
$233.41 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 50/200f 10'cap, Open-hi, Adjustable Differential, A19ABB-2
$186.89 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 200/240f, Close Differential Strap-on, A19DAF-2
$141.72 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 90/325f 10', Spst M/r, Open-hi, A19ADB-29
$179.79 each
In Stock
Get 5 by Tue, Nov 24
In Stock
Get 5 by Tue, Nov 24
Compare
Product Image of 30/110f 3.5+/-2f Fixed Knob Adjustable, A19BAC-15
30/110f 3.5+/-2f Fixed Knob Adjustable, A19BAC-15
SKU: A19BAC-15
Johnson Controls
SKU: A19BAC-15
$176.94 each
In Stock
Get 3 by Tue, Nov 24
In Stock
Get 3 by Tue, Nov 24
Compare
Product Image of Temperature Control, A19QSC-4
Temperature Control, A19QSC-4
SKU: A19QSC-4
Johnson Controls
SKU: A19QSC-4
$190.83 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Other Resources
Articles
More About A19 Series Utility Thermostats

A19 Series utility thermostats are line-voltage, single-stage controls built for simple heating or cooling applications where a low-cost, rugged control is more important than programmable scheduling. Contractors install them on unit heaters, garages, workshops, greenhouses, and other spaces where a basic call for heat or cooling is all the application needs. The design relies on a bulb-and-capillary or bimetal sensing element rather than electronics, which keeps the control simple to troubleshoot and resistant to the dust, temperature swings, and rough handling common in utility and industrial spaces. Because these thermostats switch line voltage directly, they connect straight into the heating or cooling equipment without a separate low-voltage transformer or control board, simplifying the wiring on a straightforward single-zone application. Electricians and HVAC techs reach for this series on replacement calls where a building already has line-voltage equipment and doesn't need or want a smart or programmable upgrade.

Subcategories

  • Single-Stage Heating Thermostats: Single-stage heating models switch one heating circuit on and off based on a simple temperature setpoint, without any cooling or multi-stage function. Contractors use them on unit heaters, baseboard heat, and other single-function heating equipment. Simplicity is the main selling point. There's no programming menu, just a dial or setpoint adjustment.
  • Heating/Cooling Combination Thermostats: Combination models handle both a heating call and a cooling call from a single control, useful on equipment like a package unit that needs both functions but not multi-stage operation. Techs install this style where a space has both heat and air conditioning but doesn't justify a more complex electronic thermostat.
  • Explosion-Proof and Rated Enclosures: Some A19-style thermostats come in explosion-proof or otherwise rated enclosures for use in hazardous locations, such as spaces with combustible dust or vapors. Industrial and commercial contractors specify these where code requires a rated enclosure rather than a standard housing. Matching the enclosure rating to the space classification is a code requirement, not just a preference.
  • Buying Guide

    Selecting an A19 Series thermostat starts with confirming voltage compatibility, since these controls switch line voltage directly and need to match the equipment's electrical requirements exactly. Next, decide between single-stage heating-only, cooling-only, or combination heating and cooling operation based on what the connected equipment actually does. For most straightforward replacement jobs, matching the function of the old thermostat is enough, but it's worth double-checking the equipment's control requirements rather than assuming based on the old unit's markings alone. Environment matters more with this series than with a typical residential programmable thermostat, since these controls are frequently installed in garages, greenhouses, unit heater applications, and other spaces with dust, moisture, or temperature extremes a standard thermostat wouldn't tolerate well. In any space classified as hazardous due to combustible dust or vapors, confirm that the enclosure rating meets code requirements for that classification before ordering, since a standard enclosure isn't a substitute for a rated one. Mounting style is another consideration. Some models mount directly to equipment, while others need a separate box or bracket, so check the physical mounting requirement against the installation location. Because these thermostats are built for durability over features, contractors often keep a small stock on hand for utility and industrial service calls where a fast, simple swap matters more than smart features.

    Frequently Asked Questions

    What is a line-voltage thermostat?

    It's a thermostat that switches the full line voltage running to the heating or cooling equipment directly, rather than switching a low-voltage control circuit like a typical residential thermostat. It wires straight into the equipment without needing a separate low-voltage transformer.

    Can an A19 Series thermostat replace a low-voltage thermostat?

    No, because the wiring and switching requirements are different. Swapping between line-voltage and low-voltage control requires changing how the equipment itself is wired, not just replacing the thermostat.

    Are these thermostats programmable?

    No, A19 Series units are non-programmable by design, offering a simple setpoint adjustment rather than a scheduling menu. The simplicity is part of why they hold up well in utility and industrial settings.

    What kind of equipment typically uses this thermostat?

    Unit heaters, garage and workshop heaters, greenhouse equipment, and other single-zone heating or cooling equipment that doesn't need smart or programmable control are the most common applications.

    Do these thermostats need a rated enclosure in every application?

    Only in spaces classified as hazardous due to combustible dust or vapors, where code requires an explosion-proof or otherwise rated enclosure. Standard applications like a typical garage or workshop don't require a rated enclosure.

Didn't find what you're looking for? 
Let us know
.