Shop Resideo Sale
Filter menu expanded

Filters

7,310 items
Reset

SORT

Product Availability
–

Show In Stock Only (898)

Price Range
–

Under $1 (8)
$1 to $5 (25)
$5 to $10 (109)
$10 to $15 (117)
$15 to $20 (100)
$20 to $25 (60)
$25 to $30 (96)
$30 to $35 (100)
$35 to $40 (112)
$40 to $45 (45)

AAON Parts - Furnace & AC

Help Face
Need a little help?
7310 items
Grid
List
Compare
Product Image of Reactor Line 7.5hp 5% 460v, R56150
Reactor Line 7.5hp 5% 460v, R56150
SKU: R56150
AAON
SKU: R56150
Brand: AAON
$795.43 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Heater Control Box 500w/240v, R57925
Heater Control Box 500w/240v, R57925
SKU: R57925
AAON
SKU: R57925
Brand: AAON
$1,097.13 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Coil Cwtr 30.0x 30.5 4r12f Hc, R5310A
Coil Cwtr 30.0x 30.5 4r12f Hc, R5310A
SKU: R5310A
AAON
SKU: R5310A
Brand: AAON
$4,020.27 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Flue Extension Hb, R54650
Flue Extension Hb, R54650
SKU: R54650
AAON
SKU: R54650
Brand: AAON
$217.19 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Motor .33 Ecm Cond Ge, R60390
Motor .33 Ecm Cond Ge, R60390
SKU: R60390
AAON
SKU: R60390
Brand: AAON
$1,655.16 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Motor 2 .89/3/575v/1800-1200, R57160
Motor 2 .89/3/575v/1800-1200, R57160
SKU: R57160
AAON
SKU: R57160
Brand: AAON
$3,291.63 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Distributor 7-3-5 3/16 X 25, R58410
Distributor 7-3-5 3/16 X 25, R58410
SKU: R58410
AAON
SKU: R58410
Brand: AAON
$258.78 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Trans 75va/120-480v/24v, R60080
Trans 75va/120-480v/24v, R60080
SKU: R60080
AAON
SKU: R60080
Brand: AAON
$111.60 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Hose Gas Flex Css 0.50x18.0, R89630
Hose Gas Flex Css 0.50x18.0, R89630
SKU: R89630
AAON
SKU: R89630
Brand: AAON
$56.37 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Damper Backdraft 29x29 Narrow, R90000
Damper Backdraft 29x29 Narrow, R90000
SKU: R90000
AAON
SKU: R90000
Brand: AAON
$4,168.70 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Wheel Comb C6.1 Gp, R90131
Wheel Comb C6.1 Gp, R90131
SKU: R90131
AAON
SKU: R90131
Brand: AAON
$638.52 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Fan Atli 15-11 Bt, R91080
Fan Atli 15-11 Bt, R91080
SKU: R91080
AAON
SKU: R91080
Brand: AAON
$690.30 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Handle Door Chamfer Rn, R92061
Handle Door Chamfer Rn, R92061
SKU: R92061
AAON
SKU: R92061
Brand: AAON
$33.23 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Valve Ball Mtz 1.5 Prop Cv19, R93200
Valve Ball Mtz 1.5 Prop Cv19, R93200
SKU: R93200
AAON
SKU: R93200
Brand: AAON
$1,486.43 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Seg Htwhl Sen Erc-5262, R94080
Seg Htwhl Sen Erc-5262, R94080
SKU: R94080
AAON
SKU: R94080
Brand: AAON
$1,352.05 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Prop 26x24xhub 4 Blade, R95460
Prop 26x24xhub 4 Blade, R95460
SKU: R95460
AAON
SKU: R95460
Brand: AAON
$387.19 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Motor .25/1/460v/850 Ecm Sntech, R95750
Motor .25/1/460v/850 Ecm Sntech, R95750
SKU: R95750
AAON
SKU: R95750
Brand: AAON
$843.66 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Heater Crkc 70w 240v 10.75, R61940
Heater Crkc 70w 240v 10.75, R61940
SKU: R61940
AAON
SKU: R61940
Brand: AAON
$56.37 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Thermostat 24v 1h1c Cnvhp Prog Wr, R62120
$381.92 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Board Expn Vcmx Sa, R96180
Board Expn Vcmx Sa, R96180
SKU: R96180
AAON
SKU: R96180
Brand: AAON
$891.01 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Relay Solid State Dc, R96190
Relay Solid State Dc, R96190
SKU: R96190
AAON
SKU: R96190
Brand: AAON
$119.27 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Trans 15kva 240-480v/120-240v, R96520
Trans 15kva 240-480v/120-240v, R96520
SKU: R96520
AAON
SKU: R96520
Brand: AAON
$4,054.04 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Power Supply 0.3a 120vac-24vdc, R97980
Power Supply 0.3a 120vac-24vdc, R97980
SKU: R97980
AAON
SKU: R97980
Brand: AAON
$388.30 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Dist Nozzle 7-3-11 15088-00-25, R65720
Dist Nozzle 7-3-11 15088-00-25, R65720
SKU: R65720
AAON
SKU: R65720
Brand: AAON
$135.07 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Flame Sensor, R66260
Flame Sensor, R66260
SKU: R66260
AAON
SKU: R66260
Brand: AAON
$384.36 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Condenser Coil, R6696K
Condenser Coil, R6696K
SKU: R6696K
AAON
SKU: R6696K
Brand: AAON
$18,581.22 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of Prop 42.25/3-6/29/ppg/6w/1.38, R68100
Prop 42.25/3-6/29/ppg/6w/1.38, R68100
SKU: R68100
AAON
SKU: R68100
Brand: AAON
$1,169.05 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Seal Htwhl Diam Left Erc-7490, R63850
Seal Htwhl Diam Left Erc-7490, R63850
SKU: R63850
AAON
SKU: R63850
Brand: AAON
$383.03 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Screen Blower 30 Rl, R64850
Screen Blower 30 Rl, R64850
SKU: R64850
AAON
SKU: R64850
Brand: AAON
$362.39 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Switch Flow 4100-70nc-0.3no, R65160
Switch Flow 4100-70nc-0.3no, R65160
SKU: R65160
AAON
SKU: R65160
Brand: AAON
$1,182.79 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Bracket Uv Lamp Mounting, R68920
Bracket Uv Lamp Mounting, R68920
SKU: R68920
AAON
SKU: R68920
Brand: AAON
$17.38 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Module Comp 120vac Stretch Sum, R67510
Module Comp 120vac Stretch Sum, R67510
SKU: R67510
AAON
SKU: R67510
Brand: AAON
$299.83 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Filter 24" x 16" x 2" Plt MRV8 30%, R68570
$17.39 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Blower Wheel , R69880
Blower Wheel , R69880
SKU: R69880
AAON
SKU: R69880
Brand: AAON
$658.00 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Ftg Pvc Adapt Tank 4 Sxs, R70500
Ftg Pvc Adapt Tank 4 Sxs, R70500
SKU: R70500
AAON
SKU: R70500
Brand: AAON
$816.68 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Coil Hwtr 38.8x 27.0 2r10f Hc, R7144A
Coil Hwtr 38.8x 27.0 2r10f Hc, R7144A
SKU: R7144A
AAON
SKU: R7144A
Brand: AAON
$2,364.88 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Protocol Translator Lon, R72440
Protocol Translator Lon, R72440
SKU: R72440
AAON
SKU: R72440
Brand: AAON
$3,700.67 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 5hp 480v Vfd For Supply Fan, R70350
5hp 480v Vfd For Supply Fan, R70350
SKU: R70350
AAON
SKU: R70350
Brand: AAON
$1,689.49 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Anchor Acond Side Rnc, R70840
Anchor Acond Side Rnc, R70840
SKU: R70840
AAON
SKU: R70840
Brand: AAON
$147.80 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Coil Hwtr 35.0x 24.0 2r08f Fc, R7334A
Coil Hwtr 35.0x 24.0 2r08f Fc, R7334A
SKU: R7334A
AAON
SKU: R7334A
Brand: AAON
$2,175.84 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Coil Hwtr 35.0x 24.0 2r10f Fc, R7335A
Coil Hwtr 35.0x 24.0 2r10f Fc, R7335A
SKU: R7335A
AAON
SKU: R7335A
Brand: AAON
$1,917.52 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Eprom Vcm Control Ss1016 V1.62, R74633
Eprom Vcm Control Ss1016 V1.62, R74633
SKU: R74633
AAON
SKU: R74633
Brand: AAON
$247.31 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Motor 1/3/220-440v/1450 He Odp, R75660
Motor 1/3/220-440v/1450 He Odp, R75660
SKU: R75660
AAON
SKU: R75660
Brand: AAON
$2,202.28 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Screen Econ Outside Air Rnb, R78470
Screen Econ Outside Air Rnb, R78470
SKU: R78470
AAON
SKU: R78470
Brand: AAON
$73.00 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Valve Baln Brs 2.00 Fpt 600#, R77651
Valve Baln Brs 2.00 Fpt 600#, R77651
SKU: R77651
AAON
SKU: R77651
Brand: AAON
$809.72 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Smoke Det Sampling Tube 6in, R80020
Smoke Det Sampling Tube 6in, R80020
SKU: R80020
AAON
SKU: R80020
Brand: AAON
$39.77 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Distributor 7-3-6, R80430
Distributor 7-3-6, R80430
SKU: R80430
AAON
SKU: R80430
Brand: AAON
$2,815.55 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Trans 1.5kva/460v/230v, R80460
Trans 1.5kva/460v/230v, R80460
SKU: R80460
AAON
SKU: R80460
Brand: AAON
$849.53 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Resources
FAQs, Manuals & Videos
Articles
More About AAON Parts

AAON parts are replacement components for AAON's commercial rooftop units, air handlers, and packaged HVAC equipment used in schools, offices, retail buildings, and other large commercial spaces. AAON builds its equipment for a long service life, so parts like compressors, condenser fan motors, control boards, and economizer components need to match the exact unit model to keep the system operating within its designed performance range. A technician sourcing AAON parts for an aging rooftop unit is often balancing the cost of a repair against a full unit replacement, especially once major components like compressors start failing. Having the right part number in hand before a service call keeps a routine repair from turning into an extended equipment outage for the building. Because AAON equipment spans a wide range of tonnage and configuration options, confirming the unit's full model and serial information ahead of ordering parts is worth the extra time it takes.

Subcategories

  • Compressors: AAON commercial rooftop units and packaged equipment rely on scroll or reciprocating compressors sized to the unit's tonnage, and a failed compressor is one of the most common reasons for an AAON parts order. Matching the replacement to the exact refrigerant type and voltage of the original unit is critical, since AAON's equipment lineup covers multiple refrigerants across different production years. Technicians typically pull the compressor's data plate information directly off the failed unit rather than relying on the rooftop unit's overall model number alone. A mismatched compressor can pull excess current or fail to reach design capacity, so confirming compatibility before installation avoids a repeat service call.
  • Condenser Fan Motors: Condenser fan motors move outdoor air across the condenser coil to reject heat, and a failing motor typically shows up as reduced cooling capacity or a tripped high-pressure switch before the motor stops turning. AAON specifies motor horsepower, speed, and rotation direction by unit model, so a replacement has to match those specs and not simply the physical mounting dimensions. Multi-fan rooftop units may use different motor sizes across positions, so confirming which fan location failed matters before ordering. Replacing a worn motor before it fails completely can prevent a drop in system efficiency that a building occupant would otherwise notice as reduced comfort.
  • Control Boards: Control boards manage staging, safety interlocks, and communication between an AAON unit's components, and a faulty board often presents as erratic staging or a unit that fails to respond to the thermostat at all. Because AAON has updated its control platforms across multiple equipment generations, a board pulled from a newer unit is not guaranteed to be compatible with an older rooftop unit's wiring and configuration. Technicians should verify the board revision and firmware compatibility against the specific unit before ordering a replacement. A properly matched board restores normal staging and diagnostic reporting without requiring a full control retrofit.
  • Filters: Filters protect the coil and blower assembly from dust and debris, and AAON units specify a filter size and MERV rating appropriate to the application, whether that is a school, office, or industrial space. Skipping filter changes on schedule increases static pressure across the system, which reduces airflow and can shorten the life of the blower motor. Facilities with heavier particulate loads, such as near a loading dock, often need more frequent filter changes than the standard maintenance interval. Keeping a stock of the correct filter size on hand simplifies routine maintenance visits.
  • Economizer Components: Economizer components allow an AAON rooftop unit to bring in outdoor air for free cooling when outdoor conditions permit, and typical replacement parts include actuators, dampers, and the sensors that control them. A failed actuator commonly gets stuck in one position, either locking the unit into full outdoor air or preventing it from using outdoor air at all, both of which waste energy. Confirming the actuator's torque rating and control signal type against the original unit is necessary before ordering a replacement. Restoring a working economizer often shows up quickly as a drop in a building's cooling energy use during mild weather.

Buying Guide

Ordering the right AAON part starts with the unit's full model and serial number, since AAON's product line spans multiple tonnages, refrigerant types, and control platforms across different production years, and a part that fits one configuration will not necessarily fit another with a similar-looking model number. Compressors and motors should be matched by voltage, phase, and rated horsepower or capacity rather than just physical size, since a part that bolts in place but does not match the electrical specification can trip breakers or fail to deliver rated performance. Control boards carry the added complexity of firmware and communication protocol compatibility, so pulling the exact board revision from the failed component is more reliable than guessing from the unit's age. Facilities managers weighing a parts order against a full unit replacement should factor in how many other major components have already been serviced, since a unit nearing the end of its expected service life may not justify a costly compressor or control board replacement. Filters and other wear items are the simplest category to plan for, since keeping common sizes in stock avoids delays on routine maintenance. For less common configurations, confirming availability before scheduling a repair visit helps avoid extended downtime on a commercial rooftop unit that a business depends on for daily operation. Working from the equipment's data plate rather than a general model description is the best way to avoid an ordering mistake.

Frequently Asked Questions

How can a contractor confirm a replacement part matches a specific AAON rooftop unit?

Pulling the full model and serial number off the unit's data plate is the reliable way to confirm a match, since AAON's product line covers multiple tonnages and control platforms that can share similar model prefixes.

Why do AAON control boards sometimes fail to work as direct replacements across different production years?

AAON has updated its control platforms over several equipment generations, so a board's firmware and communication protocol need to match the original unit rather than just the physical connector layout.

What typically causes an AAON condenser fan motor to fail?

Continuous outdoor exposure and long run hours wear down motor bearings over time, and a failing motor often shows reduced cooling capacity or a tripped high-pressure switch before it stops running entirely.

Is it worth replacing a failed compressor on an older AAON rooftop unit?

Whether replacing a failed compressor makes sense depends on how many other major components have already been serviced and how close the unit is to the end of its expected service life, so weighing the repair cost against a full replacement is worth doing first.

How often should filters be changed on an AAON rooftop unit?

Filter change frequency depends on the application and particulate load, with facilities near heavy dust sources such as a loading dock typically needing more frequent changes than the standard maintenance interval.