Apply to be a TradeMaster!
Filter menu expanded

Filters

107 items
Reset

SORT

Product Availability
–

Show In Stock Only (11)

Price Range
–

$10 to $15 (1)
$15 to $20 (6)
$20 to $25 (1)
$25 to $30 (3)
$30 to $35 (9)
$35 to $40 (4)
$40 to $45 (4)
$45 to $50 (4)
$60 to $70 (6)
$70 to $80 (6)

Aspen Boiler Parts

Help Face
Need a little help?
FIND PARTS FOR YOUR UNIT
107 items
Grid
List
Compare
Product Image of Supply Pipe Assembly (includes pipe assembly, gasket, & jacket grommets), 106977-02
$224.38 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of LP Gas Train Assembly, 112498-01
LP Gas Train Assembly, 112498-01
SKU: 112498-01
Burnham
SKU: 112498-01
Brand: Burnham
$827.57 each
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Compare
Product Image of Door Catch Repair Kit for ASPN-155A-6L00M, 107199-01
$74.26 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Repair Gas Pipe Adapter 5/8" OD Flare x 1/2" NPT, 107247-01
$16.23 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Conversion Kit Nat to LP ASPN-155, 107936-01
$74.74 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Flue Gasket (Heat Exchanger or Flue Pipe), 107000-02
$39.48 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Burner (includes burner and screws), 108035-03
$263.93 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 1" OD Flare x 3/4" NPT Flare Fitting For Aspen/Raptor, 108166-01
$26.03 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of LP (Propane) Conversion (includes O-ring, gsket and hardware), 108015-02
$94.97 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Thermostatic Mixing Valve, 108042-01
Thermostatic Mixing Valve, 108042-01
SKU: 108042-01
Burnham
SKU: 108042-01
Brand: Burnham
$272.29 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Floor Stand Kit for Alta Aspen, 111576-01
Floor Stand Kit for Alta Aspen, 111576-01
SKU: 111576-01
Burnham
SKU: 111576-01
Brand: Burnham
$493.82 each
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Out of Stock
Get it by Tue, Dec 8 - Tue, Dec 15
Resources
FAQs, Manuals & Videos
Articles
More About Aspen Boiler Parts

Aspen boiler parts cover the replacement components used to service Aspen high-efficiency condensing boilers, a line built around a stainless steel firetube heat exchanger designed for both residential and light commercial installations. The Aspen line is rated up to 96 percent AFUE with a 10 to 1 turndown ratio and carries an ENERGY STAR rating, and it is offered in six wall-hung residential models along with two larger light commercial models. Keeping the right parts on hand matters for service work on these units, since a condensing boiler's efficiency depends on components like the heat exchanger, ignition system, and controls all functioning within spec.

For a contractor servicing an Aspen boiler, parts availability determines how quickly a heating outage can be resolved, particularly in the colder months when downtime is least tolerable for a building owner. Because the Aspen line spans both wall-hung residential units and light commercial models, confirming the exact model and capacity before ordering parts helps avoid a mismatched component on a service call.

Subcategories

  • Heat Exchanger Components: The Aspen line is built around a stainless steel firetube heat exchanger, and replacement components for this system are central to keeping the boiler's condensing efficiency intact. A technician servicing heat exchanger issues typically works with gaskets, seals, and related hardware specific to the firetube design. Matching parts to the correct model capacity, whether a residential wall-hung unit or a light commercial model, is important since the line spans multiple output sizes.
  • Ignition and Control Components: Ignition and control components manage burner startup and monitor boiler operation to maintain the unit's rated efficiency and safety shutoffs. These parts are commonly replaced during troubleshooting calls when a unit fails to fire or shuts down unexpectedly. Because the Aspen line includes both residential and light commercial capacities, control components can vary by model.
  • Venting and Condensate Parts: As a condensing boiler, the Aspen line produces acidic condensate that must be properly drained, making condensate management parts a routine service item. Venting components are also specific to condensing operation and differ from parts used on non-condensing boiler equipment. Keeping these parts in stock supports both scheduled maintenance and emergency service calls.
  • Buying Guide

    Ordering the correct Aspen boiler part starts with identifying the exact model and capacity of the unit being serviced, since the line spans six wall-hung residential models rated from 85 to 270 MBH along with two light commercial models rated at 320 and 399 MBH. A part sized for one capacity is not necessarily compatible with another within the same product line.

    Because the Aspen boiler is built around a stainless steel firetube heat exchanger for condensing operation, technicians should prioritize heat exchanger and related sealing components when troubleshooting efficiency or leak issues, since these are central to the unit achieving its rated performance.

    Ignition and control parts are typically the first place to look when a unit fails to start or shuts down during operation, and having common replacement components on hand shortens response time on no-heat calls, particularly during peak heating season.

    Condensate and venting parts deserve regular attention even outside of a specific complaint, since condensing boilers depend on proper condensate drainage and venting to operate safely and efficiently over time. Periodic inspection of these components as part of scheduled maintenance can prevent a larger service call later.

    Aspen Boiler Parts is a category built around servicing a specific condensing boiler platform, so confirming the model and capacity before ordering is the most reliable way to avoid a wasted trip or a returned part.

    Frequently Asked Questions

    What efficiency rating does the Aspen boiler line carry?

    The Aspen line is rated up to 96 percent AFUE with a 10 to 1 turndown ratio and carries an ENERGY STAR rating, reflecting its stainless steel firetube heat exchanger design built for condensing operation.

    What sizes does the Aspen boiler line come in?

    The line includes six wall-hung residential models ranging from 85 to 270 MBH, along with two light commercial models rated at 320 and 399 MBH.

    Why does condensate drainage matter for Aspen boiler service?

    As a condensing boiler, the Aspen produces acidic condensate that must be properly drained during normal operation. Condensate and venting parts are routine service items specific to condensing boiler platforms.

    Are Aspen boiler parts interchangeable across the residential and light commercial models?

    Not necessarily. The line spans multiple capacities across both wall-hung residential and light commercial models, so parts should be matched to the specific model and capacity being serviced rather than assumed to be interchangeable.

    What should be checked first when an Aspen boiler will not fire?

    Ignition and control components are typically the first place to check when a unit fails to start or shuts down unexpectedly, since these manage burner startup and monitor safety shutoffs.

Didn't find what you're looking for? 
Let us know
.