Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Emblem Trilogy, 95B0001N40
Emblem Trilogy, 95B0001N40
SKU: 95B0001N40
ClimateMaster
SKU: 95B0001N40
$31.03 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Electronic Filter 28x30x2, AAC28302CMA
$1,540.52 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Hose Kit, AHB0752-0900
Hose Kit, AHB0752-0900
SKU: AHB0752-0900
ClimateMaster
SKU: AHB0752-0900
$379.36 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Thermal Expansion Valve, 33B0006N07
$142.38 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Residential Training Fee, RESTTTCLASS
Residential Training Fee, RESTTTCLASS
SKU: RESTTTCLASS
ClimateMaster
SKU: RESTTTCLASS
$1,325.39 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0099N06
Compressor, 34B0099N06
SKU: 34B0099N06
ClimateMaster
SKU: 34B0099N06
$1,232.24 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of ACNTRL01 Ctrl Conv Cmc-cxm, ACNTRL01
$486.48 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 20 X 36 4row Air Coil, 61S0109N55
20 X 36 4row Air Coil, 61S0109N55
SKU: 61S0109N55
ClimateMaster
SKU: 61S0109N55
$1,693.48 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Blower Assembly, S70S0004N14
Blower Assembly, S70S0004N14
SKU: S70S0004N14
ClimateMaster
SKU: S70S0004N14
$440.59 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Hose Kit Adapter, 290019N01
Hose Kit Adapter, 290019N01
SKU: 290019N01
ClimateMaster
SKU: 290019N01
$68.00 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Pump, 24B0013N04
Pump, 24B0013N04
SKU: 24B0013N04
ClimateMaster
SKU: 24B0013N04
$601.38 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Housing And Wheel, 73S0008N01
$207.88 each
In Stock
Get 2 by Tue, Oct 6
In Stock
Get 2 by Tue, Oct 6
Compare
Product Image of TXV, Hgbe-8 7/8" Odf, 33B0046N01
TXV, Hgbe-8 7/8" Odf, 33B0046N01
SKU: 33B0046N01
ClimateMaster
SKU: 33B0046N01
$653.03 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Housing, S12331625
Blower Housing, S12331625
SKU: S12331625
ClimateMaster
SKU: S12331625
$202.94 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Wire Harness, 11B0011N01
Wire Harness, 11B0011N01
SKU: 11B0011N01
ClimateMaster
SKU: 11B0011N01
$17.67 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Hose Kit Assembly Ss, AHA0502
$159.50 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Motor Pulley, 79007652
Motor Pulley, 79007652
SKU: 79007652
ClimateMaster
SKU: 79007652
$100.69 each
In Stock
Get 2 by Tue, Oct 6
In Stock
Get 2 by Tue, Oct 6
Compare
Product Image of Expansion Valve P1e 0.5, 33B0006N21
$127.72 each
In Stock
Get 2 by Tue, Oct 6
In Stock
Get 2 by Tue, Oct 6
Compare
Product Image of 5kw Heater Element, 18B0002N01
5kw Heater Element, 18B0002N01
SKU: 18B0002N01
ClimateMaster
SKU: 18B0002N01
$107.72 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0149N01
Compressor, 34B0149N01
SKU: 34B0149N01
ClimateMaster
SKU: 34B0149N01
$3,308.62 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Hose Kit 1/2 X 2' 6.00gpm, AHC0502-0600
Hose Kit 1/2 X 2' 6.00gpm, AHC0502-0600
SKU: AHC0502-0600
ClimateMaster
SKU: AHC0502-0600
$260.76 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Front Panel, 41F1088SFN
Front Panel, 41F1088SFN
SKU: 41F1088SFN
ClimateMaster
SKU: 41F1088SFN
$151.61 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor Spring, 56B0003N01
Compressor Spring, 56B0003N01
SKU: 56B0003N01
ClimateMaster
SKU: 56B0003N01
$7.02 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 115v 1ph Compressor, 34B0111N04
115v 1ph Compressor, 34B0111N04
SKU: 34B0111N04
ClimateMaster
SKU: 34B0111N04
$667.36 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 28v Green Led Indicator Light, 19B0003N03
$53.88 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0021N01
Compressor, 34B0021N01
SKU: 34B0021N01
ClimateMaster
SKU: 34B0021N01
$704.76 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Control Board, 17S0012N54
Control Board, 17S0012N54
SKU: 17S0012N54
ClimateMaster
SKU: 17S0012N54
$966.74 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coax Coil, 62C0010N01
Coax Coil, 62C0010N01
SKU: 62C0010N01
ClimateMaster
SKU: 62C0010N01
$1,218.59 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 50gal Communicating Water Tank, AWS050AW1245SB
50gal Communicating Water Tank, AWS050AW1245SB
SKU: AWS050AW1245SB
ClimateMaster
SKU: AWS050AW1245SB
$4,647.96 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Evap Coil, 61S0027N55
Evap Coil, 61S0027N55
SKU: 61S0027N55
ClimateMaster
SKU: 61S0027N55
$1,615.57 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Motor Mount Arm, 75B0001N02
Motor Mount Arm, 75B0001N02
SKU: 75B0001N02
ClimateMaster
SKU: 75B0001N02
$11.02 each
In Stock
Get 6 by Tue, Oct 6
In Stock
Get 6 by Tue, Oct 6
Compare
Product Image of Programmed ECM Converter Box, P14S0016N01
$350.66 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Overload, 115-092
Overload, 115-092
SKU: 115-092
ClimateMaster
SKU: 115-092
$439.85 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0043N04S
Compressor, 34B0043N04S
SKU: 34B0043N04S
ClimateMaster
SKU: 34B0043N04S
$782.43 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Flow Module Double Pump, AFCG2B4
$7,663.54 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Resid. Service Part Kit, ASPK
$3,574.87 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Contactor, 110-118
Contactor, 110-118
SKU: 110-118
ClimateMaster
SKU: 110-118
$524.00 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Coil 3r 20x40, 61B0164N01
Air Coil 3r 20x40, 61B0164N01
SKU: 61B0164N01
ClimateMaster
SKU: 61B0164N01
$1,416.50 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Sheet Metal Cabinet Screw, 55B0003N01
$4.24 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Filter Drier, 36B0003N10
Filter Drier, 36B0003N10
SKU: 36B0003N10
ClimateMaster
SKU: 36B0003N10
$127.90 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Harness, 11B0037N01
Harness, 11B0037N01
SKU: 11B0037N01
ClimateMaster
SKU: 11B0037N01
$35.45 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Hose Kit, AHC0502-0250
Hose Kit, AHC0502-0250
SKU: AHC0502-0250
ClimateMaster
SKU: AHC0502-0250
$534.00 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coax Coil, 62B0103N01
Coax Coil, 62B0103N01
SKU: 62B0103N01
ClimateMaster
SKU: 62B0103N01
$3,393.48 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of A34 Belt, 68540213
A34 Belt, 68540213
SKU: 68540213
ClimateMaster
SKU: 68540213
$41.14 each
In Stock
Get 6 by Tue, Oct 6
In Stock
Get 6 by Tue, Oct 6
Compare
Product Image of Aux Contact, 110-101
Aux Contact, 110-101
SKU: 110-101
ClimateMaster
SKU: 110-101
$86.67 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Reversing Valveless Coil, 69170800
$141.28 each
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Compare
Product Image of 10kw 240v Duct Heater, AGM10CAG
$458.01 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Climate Master Tsm09 Blower Whl, 68624002
$150.08 each
In Stock
Get 2 by Tue, Oct 6
In Stock
Get 2 by Tue, Oct 6
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.