Apply to be a TradeMaster!

Mr. PEX Oxygen Barrier PEX Tubing

Help Face
Need a little help?
Search Tips
  • Make sure all words are spelled correctly
  • Try different keywords (i.e., pex fittings, control valves)
  • Broaden your search
  • Call us with any questions 1-888-757-4774
Still can't find what you're looking for? 
Let us know
.
Resources
FAQs, Manuals & Videos
Videos
Articles
More About Mr. PEX Oxygen Barrier PEX Tubing

Mr. PEX oxygen barrier PEX tubing is cross-linked polyethylene pipe with an added EVOH layer that blocks oxygen molecules from diffusing through the pipe wall into a closed hydronic system. Keeping oxygen out of the water matters because dissolved oxygen accelerates corrosion of ferrous components such as boilers, circulator pumps, and cast iron radiators, shortening their service life. Contractors specify oxygen barrier tubing for radiant floor heating, baseboard, and other closed-loop hydronic applications where the system water recirculates continuously and any ferrous metal is present in the loop. Tubing without an oxygen barrier is generally reserved for open systems, such as certain snow-melt or non-metallic-only setups, where oxygen ingress doesn't threaten metal components. Choosing barrier tubing for the wrong application wastes cost, but skipping it on a system with ferrous parts risks premature equipment failure, so matching the tubing to the system design is the key decision.

Subcategories

  • Radiant Floor Heating Tubing: This tubing is run in loops beneath flooring to distribute heated water evenly across a room, making oxygen barrier protection important since these systems typically include a boiler or other ferrous components. Coil lengths are sized to match the run distances of a radiant zone without unnecessary joints. Installers snap or clip the tubing to a subfloor or embed it in concrete depending on the installation method chosen. Consistent wall thickness along the coil helps maintain even flow resistance across a zone.
  • Baseboard and Hydronic Distribution Tubing: This tubing carries hot water from a boiler to baseboard or panel radiators throughout a building's hydronic distribution system. Oxygen barrier protection is especially important here since these lines connect directly to boiler components most vulnerable to corrosion. Straight lengths or coils are chosen based on the distance and routing needed for a given zone. Compatibility with the fitting system a contractor uses, such as crimp or expansion fittings, is a key consideration when selecting tubing.
  • PEX Tubing Coils by Size: Coils are available across a range of diameters to match the flow requirements of different zones, from smaller branch runs to larger main distribution lines. Selecting the correct diameter affects both flow rate and the pressure drop across a hydronic loop. Contractors typically stock a few common sizes to cover the majority of residential and light commercial radiant and hydronic jobs. Coil length options reduce the number of couplings needed on longer runs.
  • Buying Guide

    The first decision when buying Mr. PEX oxygen barrier PEX tubing is confirming the system actually needs oxygen barrier protection. Any closed-loop hydronic system with a boiler, cast iron radiator, steel pump housing, or other ferrous component should use barrier tubing, since dissolved oxygen in the system water will otherwise accelerate internal corrosion over time.

    Next, size the tubing diameter to the zone's flow requirements rather than defaulting to whatever is on the truck. Undersized tubing increases pressure drop and can starve a zone of adequate flow, while oversized tubing adds unnecessary material cost without improving performance. Coil length also matters for install efficiency: longer coils reduce the number of couplings needed on a run, which means fewer potential leak points.

    Finally, confirm the tubing is compatible with the fitting system already in use on the job, whether that's crimp rings, clamp fittings, or expansion-style connections, since mixing incompatible fitting types with a given tubing brand can affect joint reliability. Buying tubing and fittings from a consistent, compatible system reduces callbacks tied to connection failures rather than the tubing itself.

    Frequently Asked Questions

    Why does oxygen barrier tubing matter for hydronic systems?

    Dissolved oxygen in system water accelerates corrosion of ferrous components like boilers, pumps, and cast iron radiators. An oxygen barrier layer blocks oxygen from diffusing through the pipe wall, protecting these components over the life of the system.

    Does every PEX application need oxygen barrier tubing?

    No. Systems without ferrous metal components, such as certain open-loop or non-metallic-only setups, generally don't require oxygen barrier protection. Closed-loop systems with a boiler or other ferrous parts should use barrier tubing.

    Can oxygen barrier and non-barrier PEX tubing be mixed in the same system?

    It's generally not recommended in a closed hydronic loop with ferrous components, since any section without a barrier allows oxygen ingress that can affect the whole system. Consistency across the loop protects all connected components equally.

    What fitting types work with Mr. PEX tubing?

    Compatibility depends on the specific fitting system a contractor uses, such as crimp or expansion-style fittings. Confirming the tubing and fitting system are designed to work together helps avoid connection issues.

    How is oxygen barrier tubing different to install compared to standard PEX?

    Installation methods are largely the same, since the barrier is a layer within the pipe wall rather than a change to the pipe's flexibility or connection method. The main consideration is making sure the correct barrier tubing is used wherever ferrous components are present in the system.