Apply to be a TradeMaster!
Filter menu expanded

Filters

6 items
Reset

SORT

Product Availability
–

Show In Stock Only (6)

Size
–

1" (1)
1-1/4" (1)
1-1/2" (1)

Review Score
–

(3)

Radiator Valve Accessories

Help Face
Need a little help?
6 items
Grid
List
Compare
Product Image of 1" Nut & Tailpiece
1" Nut & Tailpiece
SKU: NT-100
Matco-Norca
SKU: NT-100
Brand: Matco-Norca
(2)
$13.14 each
BOX UP & SAVE 11%
$116.50 box of 10
$11.65 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of 1-1/4" Nut & Tailpiece
1-1/4" Nut & Tailpiece
SKU: NT-125
Matco-Norca
SKU: NT-125
Brand: Matco-Norca
(1)
$22.03 each
BOX UP & SAVE 13%
$191.70 box of 10
$19.17 each
In Stock
Get 6 by Mon, Nov 23
In Stock
Get 6 by Mon, Nov 23
Compare
Product Image of 1-1/2" Bronze Nut and Tailpiece
1-1/2" Bronze Nut and Tailpiece
SKU: NTB-1500
Matco-Norca
SKU: NTB-1500
Brand: Matco-Norca
$14.99 each
BOX UP & SAVE 9%
$109.20 box of 8
$13.65 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of Radiator Valve Handle
Radiator Valve Handle
SKU: 110-170
Legend Valve
SKU: 110-170
Brand: Legend Valve
(2)
$1.42 each
In Stock
Get 17 by Mon, Nov 23
In Stock
Get 17 by Mon, Nov 23
Compare
Product Image of Chrome Plated Brass Air & Water Purge Adapter
$59.47 each
In Stock
Get 3 by Mon, Nov 23
In Stock
Get 3 by Mon, Nov 23
Compare
Product Image of Flow Meter Assembly
Flow Meter Assembly
SKU: 833-862
Legend Valve
SKU: 833-862
Brand: Legend Valve
$23.55 each
In Stock
Get 28 by Mon, Nov 23
In Stock
Get 28 by Mon, Nov 23
Resources
FAQs, Manuals & Videos
Articles
More About Radiator Valve Accessories

Radiator Valve Accessories are the small replacement and add-on parts that keep manual and thermostatic radiator valves sealed, adjustable, and serviceable over the life of a heating system. The category covers drain-off tailpieces, draintaps, adapters, cover caps, and valve inserts, each sized to fit a specific valve series such as RLV-D, RLV-S, or RA-N. A drain-off tailpiece, for example, comes finished in nickel plating and mounts directly to the RLV-D lockshield valve body, giving a technician a point to drain an individual radiator without draining the whole system. Because manufacturers size these parts to match a specific valve series and connection size, matching the accessory to the exact valve model on the radiator matters more than matching by pipe size alone. Contractors and building maintenance staff rely on this category most often during radiator servicing, balancing, or when a lockshield valve needs a new cap or insert rather than full replacement. Keeping the correct accessories on hand shortens a routine radiator service call considerably.

Subcategories

  • Drain-Off Tailpieces and Draintaps: Drain-off tailpieces and draintaps mount to the base of a lockshield valve and give a technician a dedicated point to drain a single radiator without shutting down or draining the entire heating loop. Danfoss builds a nickel-plated drain-off tailpiece specifically for the RLV-D lockshield series, while a separate draintap accessory covers the VHS, RLV-K, and RLV valve families. Building maintenance staff use these fittings most during seasonal system flushing or when a single radiator needs removal for repair or replacement. Sizing the tailpiece to the exact valve series prevents leaks at the connection point.
  • Adapters: Adapters let a radiator valve accessory or connecting pipe fit a valve body it wasn't originally designed for, bridging differences in thread pattern or connection size between valve generations. Danfoss offers adapter accessories sized for the RLV-KD, RLV-KS, RLV-KDV, and RLV-KB valve series, among others. Contractors reach for an adapter most often when replacing an older lockshield valve with a newer model but keeping the existing radiator tailpiece in place. Choosing the wrong adapter series is one of the more common causes of a leaking connection after a valve swap.
  • Cover Caps: Cover caps snap or thread over the exposed stem of a lockshield or radiator valve, protecting the adjustment mechanism from dust, tampering, and accidental bumps. Danfoss sizes cover caps to specific valve series and diameters, such as a cap built for the RLV-S valve in DN15 and DN20 sizes. Property managers use cover caps in public or shared spaces where an unsecured valve stem invites unauthorized adjustment. Replacing a cracked or missing cover cap takes only a few minutes and doesn't require draining the radiator.
  • Valve Inserts: Valve inserts are the internal component that actually regulates flow inside a radiator or thermostatic valve body, and they wear or stick well before the outer valve housing needs replacement. Danfoss builds inserts sized for the RA-N, RTD-N, and RA-UN valve series in DN10 and DN15 connection sizes. Technicians swap an insert when a valve won't fully close or won't respond to the thermostatic head anymore, rather than replacing the entire valve body. Replacing just the insert keeps the original valve body and tailpiece connections intact.

Buying Guide

Start by identifying the exact valve series already installed on the radiator, since Danfoss and other manufacturers size drain-off tailpieces, draintaps, adapters, cover caps, and inserts to match a specific valve family rather than a generic pipe size. A cover cap built for an RLV-S valve in DN15 will not fit an RA-N valve, even though both look similar from across a mechanical room. Radiator Valve Accessories fall into a few functional groups: drain fittings for isolating a single radiator, adapters for bridging older and newer valve generations, cover caps for protecting the adjustment stem, and inserts for the internal flow-regulating component. Decide which group applies before ordering, since a sticking valve usually needs a new insert rather than a full valve or a cover cap. Connection size matters within each valve family too, since DN10, DN15, and DN20 variants of the same accessory are not interchangeable. On a retrofit job, check whether the existing tailpiece and adapter fittings can carry over to a new lockshield valve, since keeping the original connections in place often saves labor compared to reworking the pipe stub-out. For public or shared spaces, cover caps protect against tampering and unauthorized adjustment, so building maintenance teams should keep a few spares on hand sized to the valves already in the building. Confirming valve series, connection size, and the specific worn part before ordering avoids a mismatched accessory and a second trip to the supply counter.

Frequently Asked Questions

What's the difference between a drain-off tailpiece and a draintap?

A drain-off tailpiece mounts directly to specific lockshield valve bodies, such as the RLV-D series, and gives a dedicated point to drain a single radiator. A draintap serves the same isolating function but fits a different set of valve families, including VHS and RLV-K series valves. Both let a technician drain one radiator without shutting down the whole heating loop.

When does a radiator valve need an adapter instead of a full replacement?

An adapter bridges a thread or connection difference between an older valve body and a newer accessory or tailpiece, avoiding a full valve swap. Danfoss builds adapters sized for several valve series, including RLV-KD, RLV-KS, RLV-KDV, and RLV-KB. Reaching for an adapter usually costs less labor than replacing the entire valve and reworking the pipe connection.

What does a cover cap protect on a radiator valve?

A cover cap shields the exposed valve stem from dust, accidental bumps, and unauthorized adjustment, which matters most in shared or public spaces. Danfoss sizes cover caps to specific valve series and diameters, such as a cap built for the RLV-S valve in DN15 and DN20. Replacing a cracked or missing cap takes a few minutes and doesn't require draining the system.

How do I know if a valve needs a new insert versus a new valve body?

A valve that won't fully close, won't respond to a thermostatic head, or feels stuck usually has a worn insert rather than a failed valve body. Danfoss builds inserts sized for valve series like RA-N, RTD-N, and RA-UN in DN10 and DN15 connections. Swapping just the insert keeps the existing valve body and radiator connections in place, which saves labor over a full valve replacement.

Do radiator valve accessories fit any valve of the same size?

Sizing alone isn't enough to confirm a fit, since manufacturers build tailpieces, adapters, caps, and inserts to match a specific valve series rather than a generic diameter. A DN15 cover cap built for an RLV-S valve will not necessarily fit a DN15 RA-N valve. Confirming the exact valve series before ordering an accessory avoids a mismatched part and a return trip.

Didn't find what you're looking for? 
Let us know
.