Aquatrol Boiler Reset Control Panel w/ DHW priority for 4 zones of pumps or 2-wire valves

Brand:
Resideo
SKU:
AQ25142B
Rating:
(3)
Q&A:
(1)
Aquatrol Boiler Reset Control Panel w/ DHW priority for 4 zones of pumps or 2-wire valves
Magnifying glass
Hover image to zoom
AQ25142B has been discontinued
Discontinued December 21, 2021
This product was discontinued by the manufacturer.
Suggested Alternative:
Aquatrol Boiler Control Panel for 4 Zones or 2 Wire Valves
SKU:AQ25042B
(2)
Order by 6PM, receive 2 by Friday
VIEW ALTERNATIVE
VIEW ALTERNATIVE

Product Highlights

–
Product Highlight: Number of Zones
4
Product Highlight: Voltage
120v

Description

–
The AQ251 family of AQUATROL Boiler Reset Controls provides simplified, energy-efficient outdoor temperature compensated control of single temperature, residential hydronic heating systems. The AQ251 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for in-creased energy efficiency with reduced boiler cycling. AQ251 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry.

Features
  • Use with AQ1000 2-wire polarity-insensitive communicating thermostats (AQ25142B and AQ25144B) or dry contact thermostat (AQ2511B0, AQ25142B, and AQ25144B).
  • 0-10 Vdc modulating output for driving a modulating/condensing boiler.
  • Displays outdoor temperature on all AQ1000 thermostats when used with an AQ12C10 outdoor sensor (included).
  • Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site "ready-to-install")
  • Customizable control settings and schedules allow for greater level of control and comfort.
  • Central programming of zone set points and setback.
  • 1- or 2-stage zoning.
  • Zoning Control for up to four zones as shipped; can be expanded to a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones by using AQ254 Add-a-Temperature expansion panels.
  • Outdoor temperature compensation (reset), or Load reset based on indoor temperature feedback.
  • Zone synchronization through Zone of Greatest Demand control.
  • Domestic hot water priority and priority override protection.
  • Line or low-voltage output for zoning equipment (pumps or valves).
  • Boiler short cycling protection.
  • Boiler post purge.
  • Freeze protection.
  • Pump/valve exercise.
  • Boiler shock prevention from cold water returning to boiler.
  • Automated test and purge feature for quick start-up and simplified troubleshooting.
  • Integral 38 VA transformer with self resetting electronic fuse.
  • 2 hour power supply (super-capacitor) to retain day and time settings during power outage.
  • Non-volatile EPROM memory retains program settings during power outage.


Specifications
  • Application: Boiler reset control for hydronic zoning system
  • Thermostat Capaiblity: AQ1000 Series 2-wire communicating thermostats and most digital thermostats
  • Setback Program: 7 day, up to 2 setback periods/day.
  • User Interface: LCD Display and a 7 button Key Pad
  • Number of Communicating Zones Controlled: 4
  • Boiler (Supply) Max. Control Temperature (F): OFF, 120F to 225 F
  • Boiler Min. Control Temperature (F): OFF, 59F to 180F
  • Outdoor Low Design Control Temperature (F): -60F to 32F
  • Return Min. Control Temperature (F): 80 F to 180 F
  • Boiler Differential: 2F to 41F (1C to 23C), or Auto (minimum 2 minutes on time)
  • Boiler Post Heat Purge: Off, 10 seconds to 30 minutes (factory default is 30 seconds)
  • Pump/Valve Exercise: 30 seconds per 2 weeks of space heating inactivity
  • Power Supply: 120V/60Hz
  • R-C Input (on Control and Zoning Modules): 24 Vac Class II (input on Control and Zoning Modules)
  • Supply/Return Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/- 0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, beta=3892.
  • Auxiliary Imput: External dry contacts connection only
  • Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA
  • Control and Zoning Panel Temperature Rating (F): 32 F to 130 F
  • Operating Humidity Range (% RH): Sensor Temperature Rating (F): -58 F to +230 F
  • Boiler Design Temperature (F): 80 to 210F

Specs

–
Application:

Boiler reset control for hydronic zoning system

Thermostat Compatibility:

AQ1000 Series 2-wire

Most Digital Thermostats

Setback Program:

7 day, up to 2 setback periods/day

User Interface:

LCD Display and a 7 button Key Pad

Number of Zones:

4

Boiler Supply Max. Control Temp:

OFF, 120F to 225 F

Boiler Min. Control Temp:

OFF, 59F to 180F

Outdoor Low Design Control Temp:

-60F to 32F

Return Min. Control Temperature (F):

80 F to 180 F

Boiler Differential:

2F to 41F, or Auto (min 2 minutes on time)

Boiler Heat Post Purge:

Off, 10 seconds to 30 minutes, Factory default is 30 sec

Pump Valve/Excercise:

30 seconds per 2 weeks of space heating inactivity

Voltage:

120v

Hertz:

60

RC Input:

24 Vac Class II

RC Output:

38 VA, 24 Vac Class II

Wiring:

10 Ft

Auxiliary Demand Input:

External dry contacts connection only

Heat Demand Input:

External dry contacts connection only

Boiler Output Rating:

24 Vac, 0.5A, 12VA

DHW Demand Input:

External dry contacts connection only

Auxiliary Low Voltage Output Rating:

24 Vac, 0.5A, 12VA

Boiler Pump Output:

120 Vac/250 Vac 5A, 1/3HP

DHW Pump/Valve Output:

120 Vac/250 Vac 5A, 1/3HP

Auxiliary Pump Output:

Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP

Zone Output Contact:

Pumps: 120 Vac/250 Vac, 5A, 1/3 HP

Control Temp Range (F):

32 F to 130 F

Operating Humidity:

5 to 90% RH, non-condensing

Sensor Temperature:

-58 F to +230 F

Dimensions:

16-1/2" wide x 8" high x 3-3/8" deep

Zoning Devices Controlled:

2-wire valves

Pumps

Boiler Design Temp:

80F to 210F

Warm Weather Shutoff Temp:

Off, 35 F to 100 F

Electric Connection:

Wire-clamp screw terminals

Contact

+
Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
Special Hours
8am–6:45pm
Monday – Thursday
8am–7:45pm
Friday
9am–7:45pm
Saturday – Sunday
9am–5:45pm


Product Reviews

3.67 out of 3 reviews
67% would recommend this product
3.67
out of 3 Reviews
67% would recommend this product
WRITE A REVIEW
5 star
67%
4 star
0%
3 star
0%
2 star
0%
1 star
33%
WRITE A REVIEW
Customer Images
Showing 1-3 of 3 reviews

Never

I hired a local HVAC company to install this. It has malfunctioned twice. Now I learn Honeywell has discontinued the product. So I am stuck. My local guy cannot get any decent information out of Honeywell. So I am stuck. Honeywell is terrible.
David
VT
7 years ago
Was this review helpful to you?

Aquatrol Boiler Reset Control Panel

We use this control panel to run our waste oil boiler. It has done a great job controlling the zones and boiler.
4 Star
Wooster Ohio
9 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Great control

Better value and flexibility than Taco controls. Comes with outdoor reset built in unlike Taco. Recover from deep setbacks by using the matching Honeywell thermostats.
KC2X
Long Island NY
14 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

1 Question
1 Question
ASK A QUESTION

Q: i just bought a crown bali boiler and am planning to to plumb my four zone system with circulators instead of zone valves. is this controller compatible?

Asked by rich 13 years ago

Add your answer

* Required Field
-

Yes this product will work with circulator pumps. I have a 4-zone heating system in our house in Maine. I might add that I put in a coal boiler furnace as the primary to supplement the existing oil hot air furnace. I put in a hydronic coil that can also be heated by the hot air coming out the oil furnace. The Aquatrol controller (the device you asked about) operates both systems; when demand is not met with the primary boiler, it turns on the hot air furnace automatically. It paid for itself in 1 year! The coal boiler also gives us unlimited hot water for the house. I am not paid to say this endorsement, but I have used almost exclusively parts from PexSupply to install the entire system including hydronic floor heating (+ pex tubing) in the renovation (house was built in 1850 on an island in Maine). PexSupply have been very responsive; when I order pumbing supplies for the house it arrives almost the next day. I am a repeat customer. Last year we spent the winter in Texas; it cost me over $14000 to keep the house @65 or somewhat cooler than what we typically set the temperature zones when there @74. I felt that the house should still be heated to protect the radiators from freeze up (that would have cost more than the amount spent to maintain @65). The Aquastat did its job unattended the entire time (now over a year). Normally when we are there the heating cost is about $7000 (@74) (half the cost is for 10 tons of coal while the other the half is for 2000 gal of oil). The combined heating system is 400,000 btu per hour but the winters are a challenge for any system and oil is the only other choice (and not very economical). When you do the actual calculations (converting BTU to kwh), coal is $0.02 /khw versus oil at $0.06 per kwh. By comparison electric is 0.18 per kwh!

Was this review helpful to you?