Apply to be a TradeMaster!
Filter menu expanded

Filters

296 items
Reset

SORT

Product Availability
–

Show In Stock Only (131)

Product Type
–

Actuator (1)
Control Module (4)
Fan Control (9)
Float Switch (1)
HVAC Part (185)
Limit Control (22)
Limit Switch (16)
Pressure Cutout (2)
Pressure Switch (40)
Relay (14)

Review Score
–

(22)
(2)

Price Range
–

$15 to $20 (5)
$20 to $25 (9)
$25 to $30 (15)
$30 to $35 (14)
$35 to $40 (4)
$40 to $45 (6)
$45 to $50 (10)
$50 to $60 (12)
$60 to $70 (9)
$70 to $80 (10)

Reznor Relay, Switch, Limit Controls

Help Face
Need a little help?
296 items
Grid
List
Compare
Product Image of Limit Control #60T-21-210D, 45537
Limit Control #60T-21-210D, 45537
SKU: 45537
Reznor
SKU: 45537
Brand: Reznor
$36.85 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Relay Type 12S20 Style 305005, 89254
$50.46 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of BD5 Fire Stat DV, 152632
BD5 Fire Stat DV, 152632
SKU: 152632
Reznor
SKU: 152632
Brand: Reznor
$403.72 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Press Sw Is20233-5274, 207177
Press Sw Is20233-5274, 207177
SKU: 207177
Reznor
SKU: 207177
Brand: Reznor
$131.96 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of On/off Switch, 146830
On/off Switch, 146830
SKU: 146830
Reznor
SKU: 146830
Brand: Reznor
$154.35 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of SPST Switch, 101901
SPST Switch, 101901
SKU: 101901
Reznor
SKU: 101901
Brand: Reznor
$55.45 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of Oil Primary Heater Control, 101916
Oil Primary Heater Control, 101916
SKU: 101916
Reznor
SKU: 101916
Brand: Reznor
$918.01 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Compare
Product Image of 35#co 60#ci Low Press Switch, 216380
35#co 60#ci Low Press Switch, 216380
SKU: 216380
Reznor
SKU: 216380
Brand: Reznor
$80.32 each
In Stock
Get 10 by Tue, Nov 24
In Stock
Get 10 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Articles
More About Reznor Relay, Switch, Limit Controls

Reznor Relay, Switch, Limit Controls cover the electrical safety and control components used on Reznor gas-fired unit heaters, including high-temperature limit switches, flame rollout switches, contactors, and relays. Contactors in the category are commonly rated 208/240V at 20A for switching heater blower motor loads. Many Reznor limit controls are factory set and non-adjustable, interrupting the electric supply to the gas valve once a fixed temperature threshold is reached, which protects the heat exchanger from overheating and stops burner operation if venting or airflow is restricted. Flame rollout switches add a second layer of protection by monitoring heat around the burner compartment and shutting down the unit if flames roll outside the combustion chamber. Technicians servicing commercial unit heaters in warehouses, garages, and manufacturing spaces rely on matching the exact Reznor part number and electrical rating when swapping a failed control, since a mismatched switch can leave a heater without proper safety cutoff. Stocking the right relay, switch, or limit control keeps gas-fired unit heaters operating safely through the heating season.

Subcategories

  • High-Temperature Limit Switches: High-temperature limit switches monitor the temperature of air passing over the unit heater's heat exchanger and cut power to the gas valve once the reading climbs past a fixed setpoint. Reznor offers auto-reset versions, such as a 240F high-temperature limit control, that restore power automatically once the heat exchanger cools. Service techs install these switches when replacing a failed original-equipment limit control on a Reznor gas-fired unit heater. Facilities that rely on continuous heat in cold storage or industrial buildings depend on this switch to prevent overheating damage to the heat exchanger.
  • Flame Rollout Switches: Flame rollout switches sit near the burner compartment and shut the unit down if flame escapes the combustion chamber instead of drawing up through the heat exchanger as designed. Rollout typically signals a blocked flue, a cracked heat exchanger, or an inducer that isn't pulling enough draft, so the switch stops burner operation until a technician corrects the cause. Reznor lists flame rollout switches alongside limit switches and relays in its unit heater control lineup, since both devices protect the same gas-fired ignition system. Commercial kitchens and warehouses that run gas-fired unit heaters treat this switch as a required safety layer next to the primary limit control.
  • Contactors and Relays: Contactors and relays switch high-amperage loads for unit heater motors and accessories without routing that current through a low-voltage thermostat or control board. Contactors in the Reznor lineup are commonly rated 208/240V at 20A, matching the blower motor circuits on typical commercial gas-fired unit heaters. Relays in the same category include destratification relays, which cycle heater fans to push warm air down from ceiling level in high-bay spaces, and multi-heater control board kits that link several units to a shared thermostat. Electricians and HVAC techs pick the exact voltage and amperage rating to keep the motor circuit protected.

Buying Guide

Start by pulling the model and serial number off the Reznor unit heater's data plate, since limit controls, switches, and relays are matched to specific heater series and won't cross over between models without confirming the electrical rating. Match the reset type next. Auto-reset limit controls restore power once the heat exchanger cools, which suits heaters that see routine temperature swings, while a heater that keeps tripping the same switch needs a technician on site anyway, so a manual reset control forces that visit before restart. Confirm voltage and amperage on any contactor or relay before ordering. A 208/240V, 20A contactor handles a typical unit heater blower motor, but multi-heater installations or larger blower motors may call for a higher-rated part, and installing an undersized contactor risks a burned-out coil or a control that welds shut under load. Reznor Relay, Switch, Limit Controls purchases should also account for flame rollout protection, since a missing or bypassed rollout switch leaves a heater without its secondary overheat safeguard. Facilities running multiple Reznor unit heaters on one heating season benefit from keeping a spare limit switch and contactor on the shelf for each model in service, since a single tripped safety device can take a whole space offline until the correct replacement part arrives. Ordering by exact Reznor part number, rather than by general switch type, prevents a mismatch that could compromise the heater's built-in safety functions.

Frequently Asked Questions

What's the difference between an auto-reset and a manual-reset limit switch on a Reznor unit heater?

An auto-reset limit switch on a Reznor unit heater restores power to the gas valve automatically once the heat exchanger cools back below the setpoint. A manual-reset limit switch stays tripped until a technician presses a reset button, which forces a service visit before the heater restarts. Facilities with a history of nuisance overheating often use the manual-reset style so a live technician confirms airflow and venting before restart.

What amperage rating does a Reznor unit heater contactor need?

Reznor unit heater contactors are commonly rated 208/240V at 20A to match typical blower motor circuits. Larger unit heaters or multi-heater setups on a shared control board may need a higher-rated contactor. Checking the data plate on the unit heater before ordering keeps the replacement contactor matched to the original motor load.

Why did the flame rollout switch trip on a Reznor unit heater?

A flame rollout switch trips when flame escapes the combustion chamber instead of drawing up through the heat exchanger as designed. Common causes include a blocked flue, a cracked heat exchanger, or an inducer that isn't pulling enough draft. Resetting the switch without correcting the underlying airflow or venting problem risks a repeat trip and continued unsafe combustion.

Can a Reznor relay or limit control be swapped for a universal part?

Reznor relays, switches, and limit controls are matched to specific unit heater series, so voltage, amperage, and mounting pattern need to line up with the original part. A universal control might fit physically but run at the wrong rating for the motor or safety circuit it's protecting. Ordering by exact Reznor part number keeps the heater's built-in safety functions intact.

How often should limit switches and contactors be checked on a Reznor unit heater?

Limit switches and contactors on a Reznor unit heater are typically checked during scheduled heating-season startup and shutdown service visits. A technician tests that the high-temperature limit trips and resets correctly and inspects the contactor for pitted contacts or a chattering coil. Catching a worn contactor or a failing limit switch during routine service prevents an unexpected heater shutdown in the middle of winter.

Didn't find what you're looking for? 
Let us know
.