Secondary Coolant Valves are Parker Hannifin solenoid valves for controlling secondary coolant, including glycol systems. The listing includes both normally open and normally closed models, such as the 10E23O2-R1021E and the 10E23C2-R1021E, each a 5/8 inch ODF valve rated at 4 Cv. Sizes run from 5/8 inch ODF to 2 1/8 inch ODF, with flow ratings from 4 Cv to 22.5 Cv. Refrigeration and chilled fluid contractors choose these valves to start or stop coolant flow to a circuit. Matching the valve to the line size, the flow requirement, and the normal state of the circuit keeps the system running as designed. A normally closed valve stays closed until the coil is energized, and a normally open valve stays open until the coil is energized. Choosing the wrong state affects what the circuit does during a power loss.
Subcategories
Buying Guide
Start with the default state. A normally closed valve blocks coolant until the coil is energized, and a normally open valve passes coolant until the coil is energized. Decide what the circuit should do during a power loss, then choose the matching style. Pairs such as the 10E23C2-R1021E (normally closed) and the 10E23O2-R1021E (normally open) share a size and flow rating.
Next, match the connection size. Secondary Coolant Valves on the listing use ODF connections, so the valve size has to match the line, from 5/8 inch ODF for the 10E23 models to 2 1/8 inch ODF for the 34E24 models.
Then check flow capacity. Cv ratings on the listing run from 4 Cv on the 5/8 inch models to 22.5 Cv on the 2 1/8 inch models, with 12.2 Cv on the 1 3/8 inch and 1 5/8 inch models. Size the valve to the coolant flow the circuit needs rather than to the line size alone.
When comparing models, confirm fluid compatibility, coil voltage, and pressure ratings in the Parker documentation for the exact model before ordering. Details vary by series, and the coolant type used in the system decides which valve is appropriate. Record the full model number, including the R1021E suffix, on the order so the right valve reaches the job.
Frequently Asked Questions
What sizes do secondary coolant valves come in?
Secondary coolant valves on this listing run from 5/8 inch ODF (10E23C2-R1021E and 10E23O2-R1021E) to 2 1/8 inch ODF (34E24C2-R1021E and 34E24O2-R1021E). Intermediate sizes include 7/8 inch, 1 1/8 inch, 1 3/8 inch, and 1 5/8 inch ODF.
What is the difference between normally open and normally closed secondary coolant valves?
A normally closed secondary coolant valve blocks flow until the coil is energized. A normally open valve passes flow until the coil is energized. Choose based on what the circuit should do when power is lost.
What Cv ratings do secondary coolant valves have?
Secondary coolant valves on this listing range from 4 Cv on the 5/8 inch models to 22.5 Cv on the 2 1/8 inch models. The 7/8 inch and 1 1/8 inch models are rated at 5 Cv, and the 1 3/8 inch and 1 5/8 inch models at 12.2 Cv.
Who makes the secondary coolant valves on this listing?
Parker Hannifin makes the secondary coolant valves on this listing, including the R1021E models and the 4140-00. Parker markets solenoid valves for secondary coolant glycol applications.
Do secondary coolant valves work with glycol?
Parker markets its solenoid valves for secondary coolant glycol applications. Secondary coolant valves differ by series, so verify compatibility with the specific coolant in the Parker documentation for the exact model.