Apply to be a TradeMaster!
Filter menu expanded

Filters

1 item
Reset

SORT

Product Availability
–

Show In Stock Only (1)

Price Range
–

$200 to $300 (1)

Selectra Series 20

Help Face
Need a little help?
1 item
Grid
List
Compare
Product Image of Controller Selectrastat (60° to 85°F)
Controller Selectrastat (60° to 85°F)
SKU: T120
Maxitrol
SKU: T120
Brand: Maxitrol
$215.41 each
In Stock
Get 2 by Tue, Nov 24
In Stock
Get 2 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Articles
More About Selectra Series 20

Selectra Series 20 is a Maxitrol electronic flame modulation system designed primarily for commercial and industrial space heating. The system works as a component of indirect-fired heating systems with atmospheric burners. Maxitrol designs Series 20 for one or more heating furnaces, up to four in total. The system uses modulating and modulating-regulating valves to control gas flow. Maxitrol's Selectra M Series modulating valves range from 3/8 inch to 1 inch pipe size, and the MR Series modulating-regulating valves range from 3/8 inch to 3 inch. Both valve types handle natural gas, manufactured gas, LPG, and gas-air mixtures. Maxitrol also offers Series 21 for makeup air heating, so confirm the application before choosing between them. Matching components to the heater matters because valve size and gas type must fit the equipment being controlled.

Subcategories

  • Modulating Valves (M Series): Selectra M Series modulating valves provide precise, non-fluctuating, instantaneous temperature control without requiring a motor. Models include M410, M420, M510, M520, M610, and M620. Pipe sizes run from 3/8 inch to 1 inch. Installers use modulating valves with Series 20 space heating systems on indirect-fired units.
  • Modulating-Regulating Valves (MR Series): MR Series valves perform the dual function of modulation and pressure regulation. Pipe sizes run from 3/8 inch to 3 inch. They handle natural gas, manufactured gas, LPG, and gas-air mixtures. Contractors choose them when one valve must modulate flow and regulate pressure.
  • Series 20 Space Heating Systems: Series 20 systems are electronic flame modulation systems for commercial and industrial space heating. They serve indirect-fired heating units with atmospheric burners. A Series 20 system is designed for one or more heating furnaces, up to four. Series 21 covers makeup air heating on the same type of equipment.

Buying Guide

Start with the application. Series 20 is built for space heating on indirect-fired units with atmospheric burners, while Series 21 is the Maxitrol choice for makeup air heating. Confirm that the heater type matches before selecting parts.

Next, count the furnaces. Maxitrol designs the system for one or more heating furnaces, up to four, so settle the furnace count before ordering parts. Single furnace and multi furnace jobs both fall within that design range.

Then size the valve. The M Series modulating valves cover pipe sizes from 3/8 inch to 1 inch, with models M410, M420, M510, M520, M610, and M620. The MR Series modulating-regulating valves cover 3/8 inch to 3 inch and combine modulation with pressure regulation. Pick the MR style when one valve has to do both jobs. Verify the pipe size of the existing gas train before choosing a valve.

Fuel type comes next. Both valve types handle natural gas, manufactured gas, LPG, and gas-air mixtures, but the heater and local code still decide what is allowed on a given job. Document the gas type on the order so the right valve model is matched to it.

When sourcing Selectra Series 20 parts, match each component to the existing system and review the Maxitrol literature for the application. Maxitrol publishes a condensed catalog covering Series 20 and 21.

Frequently Asked Questions

What is Selectra Series 20 used for?

Selectra Series 20 is a Maxitrol electronic flame modulation system for commercial and industrial space heating. It serves indirect-fired heating systems with atmospheric burners. Series 21 covers makeup air heating.

How many furnaces can a Selectra Series 20 system control?

Maxitrol designs Selectra Series 20 for one or more heating furnaces, up to four. Single furnace and multi furnace jobs both fall within that range. Confirm the furnace count before ordering components.

What valves does Selectra Series 20 use?

Selectra Series 20 uses modulating and modulating-regulating valves. M Series modulating valves cover pipe sizes from 3/8 inch to 1 inch, and MR Series valves cover 3/8 inch to 3 inch. The MR style also performs pressure regulation.

What gases do Selectra modulating valves handle?

Selectra modulating and modulating-regulating valves used with Series 20 handle natural gas, manufactured gas, LPG, and gas-air mixtures. Confirm the fuel type on the order. Local code still governs what is allowed on the job.

What is the difference between Selectra Series 20 and Series 21?

Selectra Series 20 is for space heating on indirect-fired units with atmospheric burners. Series 21 is for makeup air heating on indirect-fired units with atmospheric burners. Choose the series that matches the heater application.

Didn't find what you're looking for? 
Let us know
.