[Ie] Rated Operational Current: 12 A <= 440 V, 12 A 500 V, 9 A 690 V
[Ics] Rated Service Breaking Capacity: 10 kA 500 V, 4 kA 690 V, 50 kA 230 V, 50 kA 440 V
Typical Current Consumption: 130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 150 mA 24 V DC I maximum while closing with LUCM, 280 mA 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 35 mA 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA 24 V DC I rms sealed with LUCM
Operating Time: 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM Control Circuit, 50 ms >= 72 V closing with LUCA, LUCB, LUCC, LUCD Control Circuit, 60 ms 48 V Closing with LUCA, LUCB, LUCC, LUCD Control Circuit, 70 ms 24 V Closing with LUCA, LUCB, LUCC, LUCD Control Circuit, 75 ms Closing with LUCM Control Circuit
Mechanical Durability: 15000000 Cycles
Maximum Operating Rate: 60 cyc/mn
[Ui] Rated Insulation Voltage: 600 V UL 508, 690 V IEC 60947-1 3, 600 V CSA C22.2 No 14
Safe Separation of Circuit: 400 V SELV between the Control and Auxiliary Circuits IEC 60947-1 appendix N, 400 V SELV between the Control or Auxiliary Circuit and the Main Circuit IEC 60947-1 appendix N
Connections - Terminals: Control Circuit Screw Clamp Terminals 1 0.00…0.00 in² (0.34…1.5 mm²) Flexible with Cable End, Control Circuit Screw Clamp Terminals 1 0.00…0.00 in² (0.75…1.5 mm²) Flexible without Cable End, Control Circuit Screw Clamp Terminals 1 0.00…0.00 in² (0.75…1.5 mm²) Rigid without Cable End, Control Circuit Screw Clamp Terminals 2 0.00…0.00 in² (0.34…1.5 mm²) Flexible with Cable End, Control Circuit Screw Clamp Terminals 2 0.00…0.00 in² (0.75…1.5 mm²) Flexible without Cable End, Control Circuit Screw Clamp Terminals 2 0.00…0.00 in² (0.75…1.5 mm²) Rigid without Cable End, Power Circuit Screw Clamp Terminals 1 0.00…0.02 in² (1…10 mm²) Rigid without Cable End, Power Circuit Screw Clamp Terminals 1 0.00…0.01 in² (1…6 mm²) Flexible with Cable End, Power Circuit Screw Clamp Terminals 1 0.00…0.02 in² (2.5…10 mm²) Flexible without Cable End, Power Circuit Screw Clamp Terminals 2 0.00…0.01 in² (1…6 mm²) Flexible with Cable End, Power Circuit Screw Clamp Terminals 2 0.00…0.01 in² (1…6 mm²) Rigid without Cable End, Power Circuit Screw Clamp Terminals 2 0.00…0.01 in² (1.5…6 mm²) Flexible without Cable End
Tightening Torque: Control Circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) Flat 0.20 in (5 mm), Control Circuit 7.08…10.62 lbf.in (0.8…1.2 N.m) Philips no 1 0.20 in (5 mm), Power Circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) Flat 0.24 in (6 mm), Power Circuit 16.82…22.13 lbf.in (1.9…2.5 N.m) Philips No 2 0.24 in (6 mm)
Heat Dissipation: 2 W Control Circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W Control Circuit with LUCM
Immunity to Microbreaks: 3 ms
Immunity to Voltage Dips: 70 % / 500 ms IEC 61000-4-11
Standards: UL 508 type E, with Phase Barrier, EN 60947-6-2, IEC 60947-6-2, CSA C22.2 No 14 Type E
IP Degree of Protection: IP20 IEC 60947-1 Front Panel and Wired Terminals, IP20 IEC 60947-1 Other Faces, IP40 IEC 60947-1 Front Panel outside Connection Zone
Protective Treatment: TH IEC 60068
Ambient Air Temperature for Operation: -13…140 °F (-25…60 °C) with LUCM, -13…158 °F (-25…70 °C) with LUCA, LUCB, LUCC, LUCD
Ambient Air Temperature for Storage: -40…185 °F (-40…85 °C)
Fire Resistance: 1760 °F (960 °C) Parts Supporting Live Components IEC 60695-2-12, 1202 °F (650 °C) IEC 60695-2-12
Operating Altitude: 6561.68 ft (2000 m)
Shock Resistance: 10 gn Power Poles Open IEC 60068-2-27, 15 gn Power Poles Closed IEC 60068-2-27
Vibration Resistance: 2 gn 5…300 Hz) Power Poles Open IEC 60068-2-27, 4 gn 5…300 Hz) Power Poles Closed IEC 60068-2-27
Resistance to Electrostatic Discharge: 8 kV 3 in Open Air IEC 61000-4-2, 8 kV 4 on Contact IEC 61000-4-2
Resistance to Fast Transients: 2 kV 3 Serial Link IEC 61000-4-4, 4 kV 4 All Circuits except for Serial Link IEC 61000-4-4
Non-Dissipating Shock Wave: 1 kV Serial Mode 24...240 V AC IEC 60947-6-2, 1 kV Serial Mode 48...220 V DC IEC 60947-6-2, 2 kV Common Mode 24...240 V AC IEC 60947-6-2, 2 kV Common Mode 48...220 V DC IEC 60947-6-2
Immunity to Radioelectric Fields: 10 V IEC 61000-4-6