Apply to be a TradeMaster!
Filter menu expanded

Filters

1 item
Reset

SORT

Product Availability
–

Size
–

3/4" (1)

Position
–

Normally Closed (1)

Taco Potable Zone Sentry Valves

Help Face
Need a little help?
1 item
Grid
List
Compare
Product Image of 3/4" Normally Closed Potable Water Zone Sentry Valve (Sweat)
3/4" Normally Closed Potable Water Zone Sentry Valve (Sweat)
SKU: V075C2D2ZA024Q4A2
Taco
SKU: V075C2D2ZA024Q4A2
Brand: Taco
$362.94 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Resources
FAQs, Manuals & Videos
Videos
Articles
More About Taco Potable Zone Sentry Valves

Taco Potable Zone Sentry Valves are electronically actuated, two-way zone valves built for potable water control. Each one pairs a ball valve based body with a gear driven actuator that runs on microcircuit logic, and the family is certified to NSF 61 G. Taco rates these valves for a maximum shutoff pressure of 125 PSI, a maximum operating pressure of 300 PSI, and a fluid temperature range of 20 to 220°F. Typical jobs include combination domestic water and hydronic heating systems and water shutoff to a potable system. The sweat connection body comes with a normally open or normally closed actuator, so installers can match the valve to the control sequence on the job. Picking a valve designed for potable water matters on any job where the component touches water people drink, and the ratings listed here give a clear basis for checking fit before ordering.

Subcategories

  • Normally Closed Potable Zone Valves: Normally closed potable zone valves keep the ball valve shut until the controls call for flow. Installers use them to feed a zone or a potable branch only when a thermostat or control demands it. Taco rates the Zone Sentry for a maximum shutoff pressure of 125 PSI. A manual override button and a positional indicator on the actuator make it easy to confirm and move the ball position during service.
  • Normally Open Potable Zone Valves: Normally open potable zone valves rest in the open position and close when the control signals them. Contractors choose them where flow should continue by default and stop only on a command. Each one belongs to the NSF 61 G certified Potable Zone Sentry family. Taco lists a fluid temperature range of 20 to 220°F for the valve.
  • Two-Way Sweat Ball Valve Bodies: Two-way sweat potable zone valves use a ball valve based body with bidirectional flow capability. Plumbers and hydronic installers sweat them into the line on combination domestic water and heating systems. A single standard 40VA transformer can power a maximum of 12 valves. The universal installation orientation lets the actuator mount in the position that suits the space.

Buying Guide

Start with the application. Taco's Potable Zone Sentry is certified to NSF 61 G, so it belongs on potable water lines and combination domestic water and hydronic heating systems. Match the product to the line before comparing anything else.

Next, pick the actuator type. A normally closed valve flows only when the control calls for it, while a normally open valve stays open until the control closes it. Choose based on how the system should behave at rest.

Then check ratings against the system. Taco Potable Zone Sentry Valves list a maximum shutoff pressure of 125 PSI, a maximum operating pressure of 300 PSI, and a fluid temperature range of 20 to 220°F. The maximum ambient temperature is 135°F, so review the mounting location. Compare each number with the job's static pressure and water temperature before ordering.

Size the transformer next. One standard 40VA transformer can power a maximum of 12 valves, so count zones early and plan added capacity for larger jobs. Confirm pipe size on each product page, since the valves are two-way with sweat connections.

Finally, consider service features. The actuator includes a multi-function LED for troubleshooting, a manual override button, a positional indicator for the ball valve, and a quick-release mounting clip. When the same valve goes into many jobs, those details save diagnostic time.

Frequently Asked Questions

Are Taco Potable Zone Sentry Valves rated for drinking water?

Taco Potable Zone Sentry Valves are certified to NSF 61 G, which is the certification Taco lists for potable water use. Typical applications include combination domestic water and hydronic heating systems and water shutoff to a potable system.

How many Taco Potable Zone Sentry Valves can I run on one transformer?

Taco states that one standard 40VA transformer can power a maximum of 12 Zone Sentry valves. Count every valve on the job, including any other zone valves sharing the transformer, before sizing.

What pressure can a Taco Potable Zone Sentry Valve handle?

Taco lists a maximum shutoff pressure of 125 PSI and a maximum operating pressure of 300 PSI for the Potable Zone Sentry. The fluid temperature range is 20 to 220°F.

Do Taco Potable Zone Sentry Valves come normally open or normally closed?

Taco builds the Potable Zone Sentry as a two-way sweat valve with either a normally open or a normally closed actuator. Pick the type that matches how the potable line should behave when the control is not calling.

Can I operate a Taco Potable Zone Sentry Valve by hand during service?

Taco Potable Zone Sentry Valves include a manual override button and a positional indicator that shows the ball valve position. A multi-function LED also helps with troubleshooting.

Didn't find what you're looking for? 
Let us know
.