Apply to be a TradeMaster!
Filter menu expanded

Filters

1,690 items
Reset

SORT

Product Availability
–

Show In Stock Only (359)

Product Type
–

Aquastat (7)
Bearing Part (1)
Blower (4)
Blower Assembly (11)
Blower Part (1)
Blower Wheel (3)
Boiler Assembly (1)
Boiler Control (1)
Boiler Damper (2)
Boiler Panel (1)

Review Score
–

(105)
(5)
(2)
(1)

Price Range
–

$1 to $5 (147)
$5 to $10 (157)
$10 to $15 (18)
$15 to $20 (38)
$20 to $25 (97)
$25 to $30 (50)
$30 to $35 (53)
$35 to $40 (29)
$40 to $45 (32)
$45 to $50 (41)

Utica Dunkirk Boiler Parts

Help Face
Need a little help?
FIND PARTS FOR YOUR UNIT
1690 items
Grid
List
Compare
Product Image of WH 150/200 Flue Collector Bracket, 109008776
$23.91 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Harness Lmt, Man, Rst, Tr/ex, 240007127
$24.65 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Bushing, Bi, 1-1/4" X 1/4" Npt, 240009346
$7.22 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Bd, Fixing Spring, BD710188701V
Bd, Fixing Spring, BD710188701V
SKU: BD710188701V
Utica-Dunkirk
SKU: BD710188701V
$2.05 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Pnl, Srvc, Door, Psb, 6sec, Blue, 42500826AC
$55.62 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Pnl, Side, Lt, Ewii, 4 Section, Blue, 42500265AC
$113.81 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Bd, Pressure Switch Huba 400, BD000005679722
Bd, Pressure Switch Huba 400, BD000005679722
SKU: BD000005679722
Utica-Dunkirk
SKU: BD000005679722
$27.79 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Hook, Draw Latch, Tl-17-202-07, 240008541
$3.09 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Pnl, Rear, Dxl/mgb, 170/200, 3162604AC
$110.16 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Bd, Wiring Harness X10, Sensors, BD721814101V
$36.81 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Kit Replacement, Cnds Pipes, 380, 550003289
$109.16 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Assembly, Drwr, Afg 4, 5 Section, Stc Pilot Igntr, 240007640
$209.08 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Burner, Beckett, Nx, D/v, Exb/trb5115, 240009395
$1,580.08 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Front Panel Replacement Kit for UB95M-200, 550001477
$322.78 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of NG/LP Conversion Kit, 43300724
$77.46 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Cadcell, C554a1463/u, CD-001.01
Cadcell, C554a1463/u, CD-001.01
SKU: CD-001.01
Utica-Dunkirk
SKU: CD-001.01
$63.98 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Dvrtr, Drft, Int, Psb/wpsb6, 42500676
$200.76 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Bd, Harness, Power, Supply, Aux Control, BD722577701V
$7.86 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Assembly, Cowl, Lwr, Lt, Sfiii, Stm, 21524301
$85.48 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Gasket Ign/MXR Nort, 10066-UTICA
Gasket Ign/MXR Nort, 10066-UTICA
SKU: 10066-UTICA
Utica-Dunkirk
SKU: 10066-UTICA
$21.34 each
In Stock
Get 22 by Tue, Oct 6
In Stock
Get 22 by Tue, Oct 6
Compare
Product Image of Aquastat Limit Manual Resetl4006e, Exb/trb, 550001929
$397.80 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Gas Valve, VG-008.04
Gas Valve, VG-008.04
SKU: VG-008.04
Utica-Dunkirk
SKU: VG-008.04
$703.00 each
In Stock
Get 6 by Tue, Oct 6
In Stock
Get 6 by Tue, Oct 6
Compare
Product Image of Ins, Ps2, Base, Front, 6 Section, Pls03773-005-1, 14614116
$20.45 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Burner Assembly 380, 550003278
Burner Assembly 380, 550003278
SKU: 550003278
Utica-Dunkirk
SKU: 550003278
$535.98 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Flame Sensor Replacement, 26878
$50.36 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Dhw Ch Return Block Assembly, BD767360001V
$105.51 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Kit Replacement, Pnl, Front, Dmg380, 550003295
$326.40 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Kit Replacement, Ign, Elctrd, 240/380, 550003249
$115.84 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Manifold, 3/4", 4 Section, 146-16-011
$55.30 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Bd, Ventilator Pwm Wiring Harness, BD710993201V
$7.22 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Blower Housing w/ Wheel, 10436
$287.06 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Condensate Trap Assembly , C4223700
$106.65 each
In Stock
Get 17 by Tue, Oct 6
In Stock
Get 17 by Tue, Oct 6
Compare
Product Image of Assembly, Pnl, Rt, W/rvt, Spcr, Exb7, 109008671AC
$217.99 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Replacement Supply Block Kit, 3WV, for MAC/DCC 115 & 150, 550003878
$135.08 each
In Stock
Get 3 by Mon, Oct 5
In Stock
Get 3 by Mon, Oct 5
Compare
Product Image of 120v (pri)/24v (sec) 40VA Transformer, 38491B001
$265.03 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Natural Gas to LP Conversion Kit, 43345200
$160.40 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Rerate, Bcv, 5ew1.20/1.75, 550002668
$108.43 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Fe, Adapter, Vent, Ccb150, Chb100/130/150, FE3980B980
$298.86 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Lch/clip, W/hdw, Ecr 97, 550002229
$119.75 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Pnl, Top, Exb5, 109008610AC
Pnl, Top, Exb5, 109008610AC
SKU: 109008610AC
Utica-Dunkirk
SKU: 109008610AC
$84.53 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Conv, Lp/nat, Q90-100, S3/s4, 550002701
$138.33 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Bd, Low Voltage Wiring Harness - System, BD710993901V
$20.56 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Kit Replacement, Side, Rt,jacket Dcc/b, 550003165
$251.38 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Supt, Bracket, Jkt, 2252501
$26.60 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Gasket G1 22x30, 3x2, BD000005405001
Gasket G1 22x30, 3x2, BD000005405001
SKU: BD000005405001
Utica-Dunkirk
SKU: BD000005405001
$3.99 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Harn Wire Rollout Switch, 37614501
$6.99 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Harness, Pcbx8, Pump, 240011692
Harness, Pcbx8, Pump, 240011692
SKU: 240011692
Utica-Dunkirk
SKU: 240011692
$17.76 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Pin, Drive Lock, 1/4x1-3/4, 1497, HW06801
Pin, Drive Lock, 1/4x1-3/4, 1497, HW06801
SKU: HW06801
Utica-Dunkirk
SKU: HW06801
$4.17 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Resources
FAQs, Manuals & Videos
Articles
More About Utica Dunkirk Boiler Parts

Utica Dunkirk boiler parts are replacement components built for the Utica Boilers and Dunkirk Boilers lines, two residential and light commercial boiler brands manufactured under the same parent company and sharing many core platforms.

A tech pulling a part for one of these boilers needs the exact component for the model and series on the rating plate, since a hot surface igniter, circuit board, or blower that fits one series won't necessarily seat or wire into another. Keeping the common failure parts on hand for these units, rather than waiting on a special order, keeps a no-heat call from turning into an overnight job.

Subcategories

  • Ignition & Pilot Components: Hot surface igniters, pilot assemblies, and flame sensors that light the burner and confirm flame presence to the control board. These are the most common no-heat failure point on a gas-fired Utica or Dunkirk boiler and the first thing a tech checks on a service call. Swapping a cracked igniter or a fouled flame sensor is usually a same-visit fix.
  • Circuit Boards & Controls: Integrated control boards, aquastats, and limit controls that manage ignition sequence, water temperature, and safety shutoffs. A board that won't communicate with the igniter or won't hold a call for heat is often the real cause behind an intermittent lockout. Matching the board revision to the boiler's control panel keeps wiring harnesses plug-and-play.
  • Blower Motors & Draft Inducers: Combustion air blowers and draft inducer motors that pull exhaust through the heat exchanger on power-vented models. A failing inducer usually shows up as a pressure switch fault before the motor fully seizes. Replacing it with the correct CFM-rated motor keeps the boiler's venting safety switch reading properly.
  • Gaskets, Seals & Combustion Chamber Parts: Door gaskets, flue gaskets, and combustion chamber liners that seal the boiler's firebox against exhaust leakage. These wear from repeated heat cycling and are a routine part of an annual boiler tune-up. Replacing a hardened gasket during scheduled maintenance is far cheaper than a callback for a sooting or nuisance-lockout complaint.

Buying Guide

Start with the boiler's rating plate, not a general description of the failed part. Utica and Dunkirk share platforms across several gas and oil-fired series, but the exact igniter, board revision, or blower can differ between an atmospheric-vent model and a power-vented one even within the same nominal size.

For Utica Dunkirk boiler parts, confirm whether the unit is gas or oil-fired first, since ignition and burner components are not interchangeable between fuel types. A gas boiler's hot surface igniter and flame sensor have no equivalent on an oil-fired unit, which instead uses a burner motor, nozzle, and cad cell.

Once fuel type is confirmed, match the part number against the boiler's series and revision letter if the manual lists one. A control board or wiring harness pulled from the wrong revision can physically plug in but fail to complete the ignition sequence correctly.

Finally, weigh OEM parts against aftermarket-equivalent options. OEM parts match the original fit exactly and preserve any remaining manufacturer warranty on the unit, which matters most on a boiler still within its parts-warranty window.

Frequently Asked Questions

How do I know if I need an igniter or a flame sensor?

If the burner never lights, suspect the igniter first. If it lights but then shuts down a few seconds later, the flame sensor likely isn't detecting the flame and is telling the control board to shut off gas flow.

Are Utica and Dunkirk parts interchangeable?

Often yes within the same series, since both brands share manufacturing platforms, but always confirm against the specific model and revision on the rating plate before ordering. Don't assume compatibility across different series sizes.

Why does my boiler's draft inducer run but the unit still locks out?

The pressure switch may not be sensing the airflow the inducer is producing, which can mean a weak inducer, a blocked venting or intake, or a cracked pressure switch hose rather than the motor itself.

Can I replace a gasket without draining the boiler?

It depends on which gasket. A door or jacket gasket usually doesn't require draining, but any gasket on a water-side connection, like a flange or tankless coil cover, does require the system to be drained down first.

Do I need the exact OEM board or will a universal control work?

For most Utica and Dunkirk models, the OEM board is the safer choice because it preserves the factory ignition sequence and safety logic. A universal control can work on some setups but should only be used when the OEM board isn't available.