Apply to be a TradeMaster!
Filter menu expanded

Filters

1,690 items
Reset

SORT

Product Availability
–

Show In Stock Only (241)

Product Type
–

Aquastat (7)
Bearing Part (1)
Blower (4)
Blower Assembly (11)
Blower Part (1)
Blower Wheel (3)
Boiler Assembly (1)
Boiler Control (1)
Boiler Damper (2)
Boiler Panel (1)

Review Score
–

(105)
(5)
(2)
(1)

Price Range
–

$1 to $5 (147)
$5 to $10 (157)
$10 to $15 (18)
$15 to $20 (38)
$20 to $25 (97)
$25 to $30 (50)
$30 to $35 (53)
$35 to $40 (29)
$40 to $45 (32)
$45 to $50 (41)

Utica Dunkirk Boiler Parts

Help Face
Need a little help?
FIND PARTS FOR YOUR UNIT
1690 items
Grid
List
Compare
Product Image of Aquastat (180-240F), 43300523
$603.97 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Control Board, 550001524
Control Board, 550001524
SKU: 550001524
Utica-Dunkirk
SKU: 550001524
$113.15 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Shaft End Bearing, 240002460
Shaft End Bearing, 240002460
SKU: 240002460
Utica-Dunkirk
SKU: 240002460
$39.86 each
In Stock
Get 1 by Wed, Oct 7
In Stock
Get 1 by Wed, Oct 7
Compare
Product Image of Control CSD Lockout Daughter Board, 1140008
$159.49 each
In Stock
Get 2 by Mon, Oct 5
In Stock
Get 2 by Mon, Oct 5
Compare
Product Image of Kit Replacement, Blower, Ssc/vlt 200, 550002293
$877.47 each
In Stock
Get 1 by Wed, Oct 7
In Stock
Get 1 by Wed, Oct 7
Compare
Product Image of Circuit Board/Wire AT 2 Element w/ Circuit Breaker for AT0623, 550001624
$529.31 each
In Stock
Get 1 by Mon, Oct 5
In Stock
Get 1 by Mon, Oct 5
Compare
Product Image of Dmpr, Vent, Plstc, Str Rlf, 5 In, 240006937
$253.95 each
In Stock
Get 2 by Mon, Oct 5
In Stock
Get 2 by Mon, Oct 5
Compare
Product Image of 1/8" NPT Vent Air Purge, 1580006
$27.46 each
In Stock
Get 1 by Wed, Oct 7
In Stock
Get 1 by Wed, Oct 7
Compare
Product Image of Sensor, Flue, 1/4"l45, 12k, Ntc, 3%, 240008227
$58.36 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of 48" Sensor Wire, 14662010
48" Sensor Wire, 14662010
SKU: 14662010
Utica-Dunkirk
SKU: 14662010
$38.25 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Pressure Switch, 240013044
Pressure Switch, 240013044
SKU: 240013044
Utica-Dunkirk
SKU: 240013044
$57.36 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of RTD Sensor for Argo AT Series Boilers, 240004757
$55.08 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Thermocouple 30", 146-62-039
Thermocouple 30", 146-62-039
SKU: 146-62-039
Utica-Dunkirk
SKU: 146-62-039
$20.09 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Fuse, 3.15a, 250v, Td, 97gb, S506-3.15-r +, 240008665
$5.40 each
In Stock
Get 3 by Mon, Oct 5
In Stock
Get 3 by Mon, Oct 5
Compare
Product Image of Fe, Gaskets, Ccb150/chb150, FE3980C000
$103.03 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of LP Gas Valve, VG01702
LP Gas Valve, VG01702
SKU: VG01702
Utica-Dunkirk
SKU: VG01702
$592.96 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Fire Door Insulation, 14614015
Fire Door Insulation, 14614015
SKU: 14614015
Utica-Dunkirk
SKU: 14614015
(1)
$56.18 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Housing & Wheel, 30626-UTICA
Blower Housing & Wheel, 30626-UTICA
SKU: 30626-UTICA
Utica-Dunkirk
SKU: 30626-UTICA
$179.94 each
In Stock
Get 1 by Mon, Oct 5
In Stock
Get 1 by Mon, Oct 5
Compare
Product Image of Temperature Sensor, FE3980C040
Temperature Sensor, FE3980C040
SKU: FE3980C040
Utica-Dunkirk
SKU: FE3980C040
$39.64 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Orf, Pilot, 390686-36 Hw Lp Bbr_11, PB00208
$5.36 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Ignitor, 550001527
Ignitor, 550001527
SKU: 550001527
Utica-Dunkirk
SKU: 550001527
$47.06 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Inducer Assembly w/o Gasket, 14626052
$541.65 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of W/shtr Burner Assembly, 3342601
$86.85 each
In Stock
Get 3 by Mon, Oct 5
In Stock
Get 3 by Mon, Oct 5
Compare
Product Image of Bd, O-ring 21, 5x3 Ep7, BD710963001V
Bd, O-ring 21, 5x3 Ep7, BD710963001V
SKU: BD710963001V
Utica-Dunkirk
SKU: BD710963001V
$2.05 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 1p 24v 30a Contactor w/ Shunt, 240000769
$32.70 each
In Stock
Get 6 by Mon, Oct 5
In Stock
Get 6 by Mon, Oct 5
Compare
Product Image of Seal, Heat Exchanger, Door, Front, BD722003801V
$23.03 each
In Stock
Get 1 by Wed, Oct 7
In Stock
Get 1 by Wed, Oct 7
Compare
Product Image of Probe, 1/2"npt, Hl, Cyclegrd, W/flg, 45-220, 240010925
$72.72 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Pipe, Cpvc, Sch40, 2"x29 1/2", S636, #d52370, 240006820
$71.82 each
In Stock
Get 1 by Mon, Oct 5
In Stock
Get 1 by Mon, Oct 5
Compare
Product Image of Bd, Overtemp. Thermostat, BD710626001V
Bd, Overtemp. Thermostat, BD710626001V
SKU: BD710626001V
Utica-Dunkirk
SKU: BD710626001V
$4.39 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of .14"wc N/O Pressure Switch, 240007140
$57.67 each
Backorder
Get it by Fri, Oct 23 - Fri, Oct 30
Backorder
Get it by Fri, Oct 23 - Fri, Oct 30
Compare
Product Image of Bd, Temperature Sensor Tods, BD722143801V
$33.95 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Steam Gauge (0-30 psi), 550003355
$103.07 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Left Discharge Inducer Assembly, 5612802
$654.72 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Kit Replacement, Gas Valve, Ssc/vlt 100, 550002286
$503.26 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Outdoor Sensor, BD710487302V
Outdoor Sensor, BD710487302V
SKU: BD710487302V
Utica-Dunkirk
SKU: BD710487302V
$53.50 each
In Stock
Get 2 by Mon, Oct 5
In Stock
Get 2 by Mon, Oct 5
Compare
Product Image of Hydrolevel Control with Sensor, 240009113
$330.25 each
In Stock
Get 2 by Mon, Oct 5
In Stock
Get 2 by Mon, Oct 5
Compare
Product Image of Coil, Tl, Emp, 3.7gpm, Cdb, 14627020
$585.62 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Ins, 1"x3"x20 3/4"front, Base, Pilot Cmrcl500, 420001045
$29.20 each
In Stock
Get 2 by Mon, Oct 5
In Stock
Get 2 by Mon, Oct 5
Compare
Product Image of 8" Vent Damper, 240006940
8" Vent Damper, 240006940
SKU: 240006940
Utica-Dunkirk
SKU: 240006940
$280.50 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of BD,AIR VENT Valve G3/8,240/380, BD000005652731
BD,AIR VENT Valve G3/8,240/380, BD000005652731
SKU: BD000005652731
Utica-Dunkirk
SKU: BD000005652731
$10.99 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Burner Replacement Kit, 2272149
$178.94 each
In Stock
Get 3 by Mon, Oct 5
In Stock
Get 3 by Mon, Oct 5
Compare
Product Image of NG to LP Conversion Kit, 550002722
$109.50 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Kit Replacement, Burner Insp, Ssc/vlt 299, 550002818
$47.45 each
In Stock
Get 1 by Mon, Oct 5
In Stock
Get 1 by Mon, Oct 5
Compare
Product Image of Fe, Outlet Pipe, Dhw, Ccb150, FE3841L390
$58.68 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Bd, Air Vent Pump Gr, BD710493600
Bd, Air Vent Pump Gr, BD710493600
SKU: BD710493600
Utica-Dunkirk
SKU: BD710493600
$33.61 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Orf, 1/8, Brs, 2.9mm, 240007403
Orf, 1/8, Brs, 2.9mm, 240007403
SKU: 240007403
Utica-Dunkirk
SKU: 240007403
$6.23 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of High Limit Control, 240009128
High Limit Control, 240009128
SKU: 240009128
Utica-Dunkirk
SKU: 240009128
$208.46 each
In Stock
Get 2 by Mon, Oct 5
In Stock
Get 2 by Mon, Oct 5
Compare
Product Image of LWCO w/Mnts Pnl, 1280013
LWCO w/Mnts Pnl, 1280013
SKU: 1280013
Utica-Dunkirk
SKU: 1280013
$209.47 each
In Stock
Get 1 by Mon, Oct 5
In Stock
Get 1 by Mon, Oct 5
Resources
FAQs, Manuals & Videos
Articles
More About Utica Dunkirk Boiler Parts

Utica Dunkirk boiler parts are replacement components built for the Utica Boilers and Dunkirk Boilers lines, two residential and light commercial boiler brands manufactured under the same parent company and sharing many core platforms.

A tech pulling a part for one of these boilers needs the exact component for the model and series on the rating plate, since a hot surface igniter, circuit board, or blower that fits one series won't necessarily seat or wire into another. Keeping the common failure parts on hand for these units, rather than waiting on a special order, keeps a no-heat call from turning into an overnight job.

Subcategories

  • Ignition & Pilot Components: Hot surface igniters, pilot assemblies, and flame sensors that light the burner and confirm flame presence to the control board. These are the most common no-heat failure point on a gas-fired Utica or Dunkirk boiler and the first thing a tech checks on a service call. Swapping a cracked igniter or a fouled flame sensor is usually a same-visit fix.
  • Circuit Boards & Controls: Integrated control boards, aquastats, and limit controls that manage ignition sequence, water temperature, and safety shutoffs. A board that won't communicate with the igniter or won't hold a call for heat is often the real cause behind an intermittent lockout. Matching the board revision to the boiler's control panel keeps wiring harnesses plug-and-play.
  • Blower Motors & Draft Inducers: Combustion air blowers and draft inducer motors that pull exhaust through the heat exchanger on power-vented models. A failing inducer usually shows up as a pressure switch fault before the motor fully seizes. Replacing it with the correct CFM-rated motor keeps the boiler's venting safety switch reading properly.
  • Gaskets, Seals & Combustion Chamber Parts: Door gaskets, flue gaskets, and combustion chamber liners that seal the boiler's firebox against exhaust leakage. These wear from repeated heat cycling and are a routine part of an annual boiler tune-up. Replacing a hardened gasket during scheduled maintenance is far cheaper than a callback for a sooting or nuisance-lockout complaint.

Buying Guide

Start with the boiler's rating plate, not a general description of the failed part. Utica and Dunkirk share platforms across several gas and oil-fired series, but the exact igniter, board revision, or blower can differ between an atmospheric-vent model and a power-vented one even within the same nominal size.

For Utica Dunkirk boiler parts, confirm whether the unit is gas or oil-fired first, since ignition and burner components are not interchangeable between fuel types. A gas boiler's hot surface igniter and flame sensor have no equivalent on an oil-fired unit, which instead uses a burner motor, nozzle, and cad cell.

Once fuel type is confirmed, match the part number against the boiler's series and revision letter if the manual lists one. A control board or wiring harness pulled from the wrong revision can physically plug in but fail to complete the ignition sequence correctly.

Finally, weigh OEM parts against aftermarket-equivalent options. OEM parts match the original fit exactly and preserve any remaining manufacturer warranty on the unit, which matters most on a boiler still within its parts-warranty window.

Frequently Asked Questions

How do I know if I need an igniter or a flame sensor?

If the burner never lights, suspect the igniter first. If it lights but then shuts down a few seconds later, the flame sensor likely isn't detecting the flame and is telling the control board to shut off gas flow.

Are Utica and Dunkirk parts interchangeable?

Often yes within the same series, since both brands share manufacturing platforms, but always confirm against the specific model and revision on the rating plate before ordering. Don't assume compatibility across different series sizes.

Why does my boiler's draft inducer run but the unit still locks out?

The pressure switch may not be sensing the airflow the inducer is producing, which can mean a weak inducer, a blocked venting or intake, or a cracked pressure switch hose rather than the motor itself.

Can I replace a gasket without draining the boiler?

It depends on which gasket. A door or jacket gasket usually doesn't require draining, but any gasket on a water-side connection, like a flange or tankless coil cover, does require the system to be drained down first.

Do I need the exact OEM board or will a universal control work?

For most Utica and Dunkirk models, the OEM board is the safer choice because it preserves the factory ignition sequence and safety logic. A universal control can work on some setups but should only be used when the OEM board isn't available.