Apply to be a TradeMaster!
Filter menu expanded

Filters

460,971 items
Reset

SORT

Wilo Top S Pump Parts

Help Face
Need a little help?
460971 items
Grid
List
Compare
Product Image of Stubby Combination Wrench Set w/ Modular Organizers, 41-Piece (1/4"- 1-1/4", 6 - 32mm, Common Sizes)
Stubby Combination Wrench Set w/ Modular Organizers, 41-Piece (1/4"- 1-1/4", 6 - 32mm, Common Sizes)
SKU: WCB95410
Tekton
SKU: WCB95410
Brand: Tekton
$268.79 each
In Stock
Get 200 by Wed, Nov 25 - Fri, Nov 27
In Stock
Get 200 by Wed, Nov 25 - Fri, Nov 27
Compare
Product Image of WCC024F100BG Parts - Trane Heat Pumpnot-to-sell-product
WCC024F100BG Parts - Trane Heat Pump
SKU: WCC024F100BG
Trane
SKU: WCC024F100BG
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCC030F101BH Parts - Trane Heat Pumpnot-to-sell-product
WCC030F101BH Parts - Trane Heat Pump
SKU: WCC030F101BH
Trane
SKU: WCC030F101BH
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCC036FW00BG Parts - Trane Heat Pumpnot-to-sell-product
WCC036FW00BG Parts - Trane Heat Pump
SKU: WCC036FW00BG
Trane
SKU: WCC036FW00BG
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCC036FW00BH Parts - Trane Heat Pumpnot-to-sell-product
WCC036FW00BH Parts - Trane Heat Pump
SKU: WCC036FW00BH
Trane
SKU: WCC036FW00BH
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCC048F10EBA Parts - Trane Heat Pumpnot-to-sell-product
WCC048F10EBA Parts - Trane Heat Pump
SKU: WCC048F10EBA
Trane
SKU: WCC048F10EBA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of FB48 3-Phase TEFC General Purpose Motor, 326 Frame (230/460V, 50 HP, 3565 RPM), X50P1BS
$8,284.69 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of FB44 3-Phase TEFC General Purpose Motor, 326 Frame (230/460V, 50 HP, 1780 RPM), X50P2B
$7,055.28 each
In Stock
Get 1 by Tue, Dec 1 - Fri, Dec 4
In Stock
Get 1 by Tue, Dec 1 - Fri, Dec 4
Compare
Product Image of Merv 16 Media Filter for PCO20-28, X6669
$207.23 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of WJH324000K000A2 Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Series 975XL O-Ring
Series 975XL O-Ring
SKU: WK-019N
Zurn
SKU: WK-019N
Brand: Zurn
$9.59 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Aluminum Device Electrical Box Cover, WM1V-GY
$23.69 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Shelf, WM67800100
Shelf, WM67800100
SKU: WM67800100
Turbo Air
SKU: WM67800100
Brand: Turbo Air
$139.26 each
In Stock
Get 5 by Wed, Nov 25
In Stock
Get 5 by Wed, Nov 25
Compare
Product Image of XA-12C00NTAAC6 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-12C00NTAAC6 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-12C00NTAAC6
Coleman
SKU: XA-12C00NTAAC6
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-12E24NWAAA5 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-12E24NWAAA5 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-12E24NWAAA5
Coleman
SKU: XA-12E24NWAAA5
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-12E24VTAAA6 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-12E24VTAAA6 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-12E24VTAAA6
Coleman
SKU: XA-12E24VTAAA6
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-12E54NTAAA5 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-12E54NTAAA5 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-12E54NTAAA5
Coleman
SKU: XA-12E54NTAAA5
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-15C00ATAAA1 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-15C00ATAAA1 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-15C00ATAAA1
Coleman
SKU: XA-15C00ATAAA1
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCC060F30NBC Parts - Trane Heat Pumpnot-to-sell-product
WCC060F30NBC Parts - Trane Heat Pump
SKU: WCC060F30NBC
Trane
SKU: WCC060F30NBC
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCC060F40NBD Parts - Trane Heat Pumpnot-to-sell-product
WCC060F40NBD Parts - Trane Heat Pump
SKU: WCC060F40NBD
Trane
SKU: WCC060F40NBD
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCCL2MLSZ Luminator High Visibility Reflective Safety Vest w/ Orange Silver Stripes, Lime/Black (2XL)
$20.48 each
In Stock
Get 79 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 79 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of WCD150Z30GAA Parts - Trane Heat Pumpnot-to-sell-product
WCD150Z30GAA Parts - Trane Heat Pump
SKU: WCD150Z30GAA
Trane
SKU: WCD150Z30GAA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCD240Z300AA Parts - Trane Heat Pumpnot-to-sell-product
WCD240Z300AA Parts - Trane Heat Pump
SKU: WCD240Z300AA
Trane
SKU: WCD240Z300AA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DY09 3-Phase TEFC General Purpose Motor, 213 Frame (575V, 7.5 HP, 1765 RPM), X7P2G
$1,958.81 each
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of X8MPN150J20A1 Parts - Heil Quaker (ICP) Furnacenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-10C00NTAAA4 Parts - Coleman Packaged Unit/RTUnot-to-sell-product
XA-10C00NTAAA4 Parts - Coleman Packaged Unit/RTU
SKU: XA-10C00NTAAA4
Coleman
SKU: XA-10C00NTAAA4
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-10E24NTAAA6 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-10E24NTAAA6 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-10E24NTAAA6
Coleman
SKU: XA-10E24NTAAA6
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-10E36ATAAA4 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-10E36ATAAA4 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-10E36ATAAA4
Coleman
SKU: XA-10E36ATAAA4
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WMAHM2000AAA Parts - Goodman Gas Furnacenot-to-sell-product
WMAHM2000AAA Parts - Goodman Gas Furnace
SKU: WMAHM2000AAA
Goodman
SKU: WMAHM2000AAA
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WMAHV2000ABA Parts - Goodman Gas Furnacenot-to-sell-product
WMAHV2000ABA Parts - Goodman Gas Furnace
SKU: WMAHV2000ABA
Goodman
SKU: WMAHV2000ABA
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WMC12-1 Parts - Goodman Air Handlernot-to-sell-product
WMC12-1 Parts - Goodman Air Handler
SKU: WMC12-1
Goodman
SKU: WMC12-1
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Maestro Dual-Tech Motion Sensor Switch, Vacancy Only, TAA Compliant, 6A, 120-277V, Single Pole
$93.52 each
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of XA-15E18AWAAA1 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-15E18AWAAA1 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-15E18AWAAA1
Coleman
SKU: XA-15E18AWAAA1
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-20C00NTAAA1 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-20C00NTAAA1 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-20C00NTAAA1
Coleman
SKU: XA-20C00NTAAA1
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-20E36DTAZZ10001 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-20E36DTAZZ10001 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-20E36DTAZZ10001
Coleman
SKU: XA-20E36DTAZZ10001
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 3/8" Drive Crowfoot Wrench Set, 17-Piece (8-24mm)
$185.00 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 3/8" Drive Crowfoot Wrench Set, 21-Piece (5/16-3/4", 8-19mm)
$205.00 each
In Stock
Get 48 by Wed, Nov 25 - Fri, Nov 27
In Stock
Get 48 by Wed, Nov 25 - Fri, Nov 27
Compare
Product Image of 3/8" Drive Crowfoot Wrench Set with Key, 30-Piece (5/16-1", 8-24mm)
$330.00 each
In Stock
Get 48 by Wed, Nov 25 - Fri, Nov 27
In Stock
Get 48 by Wed, Nov 25 - Fri, Nov 27
Compare
Product Image of WCH042B100BC Parts - Trane Heat Pumpnot-to-sell-product
WCH042B100BC Parts - Trane Heat Pump
SKU: WCH042B100BC
Trane
SKU: WCH042B100BC
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCH060A100AA Parts - Trane Heat Pumpnot-to-sell-product
WCH060A100AA Parts - Trane Heat Pump
SKU: WCH060A100AA
Trane
SKU: WCH060A100AA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCH060C30FAA Parts - Trane Heat Pumpnot-to-sell-product
WCH060C30FAA Parts - Trane Heat Pump
SKU: WCH060C30FAA
Trane
SKU: WCH060C30FAA
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of WCH075C40FBB Parts - Trane Heat Pumpnot-to-sell-product
WCH075C40FBB Parts - Trane Heat Pump
SKU: WCH075C40FBB
Trane
SKU: WCH075C40FBB
Brand: Trane
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-10E36HTAZZ60001 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-10E36HTAZZ60001 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-10E36HTAZZ60001
Coleman
SKU: XA-10E36HTAZZ60001
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-10E36NTAAA4 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-10E36NTAAA4 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-10E36NTAAA4
Coleman
SKU: XA-10E36NTAAA4
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-10E36VWZAA6 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-10E36VWZAA6 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-10E36VWZAA6
Coleman
SKU: XA-10E36VWZAA6
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-12E24NTVAC6 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-12E24NTVAC6 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-12E24NTVAC6
Coleman
SKU: XA-12E24NTVAC6
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-12E24PTAAC4 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-12E24PTAAC4 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-12E24PTAAC4
Coleman
SKU: XA-12E24PTAAC4
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of XA-12E54EWEZZ50002 Parts - Coleman Packaged Unit/Rooftop Unitnot-to-sell-product
XA-12E54EWEZZ50002 Parts - Coleman Packaged Unit/Rooftop Unit
SKU: XA-12E54EWEZZ50002
Coleman
SKU: XA-12E54EWEZZ50002
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Top S Pump Parts

Wilo Top S pump parts keep the Wilo Top S line of hydronic circulator pumps running in residential and light commercial heating and cooling systems. Wilo Top S circulators move hot or chilled water through hydronic piping in boiler, radiant, and fan coil applications, and replacement parts extend the service life of pumps already installed in the field. Common parts include motor cartridges, seal kits, gaskets, and control modules that wear or fail well before the pump housing itself needs replacement. Technicians servicing a Wilo Top S pump typically diagnose whether the issue is electrical, mechanical, or related to a worn wet end before ordering parts. Stocking the right cartridge and seal combination for a given pump size shortens repair time on a callback. Sourcing genuine Wilo replacement parts helps maintain the pump's original flow and efficiency performance rather than settling for a full pump swap.

Subcategories

  • Motor Cartridges: Motor cartridges contain the wet-rotor motor assembly that drives the pump impeller. Technicians replace a cartridge when the motor windings fail or bearings wear out, since the cartridge can typically be swapped without removing the pump body from the piping. Matching cartridge voltage and pump size to the installed housing is essential for proper fit. Replacing the cartridge alone is usually faster and less disruptive than replacing the entire pump.
  • Seal and Gasket Kits: Seal and gasket kits address leaks at the pump housing and cartridge interface, a common failure point in circulators that run continuously through a heating season. Technicians inspect for mineral buildup or a hardened gasket before assuming the pump body itself is damaged. Replacing seals proactively during scheduled maintenance can prevent a leak from becoming a no-heat emergency call. Kits are sized to match specific Wilo Top S pump models.
  • Control Modules: Control modules on variable-speed Wilo Top S pumps manage speed settings and communicate operating status. A failed module often causes the pump to run at a fixed speed or stop responding to system demand. Technicians troubleshoot wiring and power supply before replacing a module outright. Choosing the correct module version for the pump's control type avoids compatibility issues.
  • Flanges and Mounting Hardware: Flanges and mounting hardware connect the Wilo Top S pump body to the system piping and support proper alignment. Worn or corroded flange gaskets are a frequent source of slow leaks around the pump connection points. Technicians replace flange hardware during a full pump service to prevent recurring leaks. Correct flange sizing keeps the pump properly aligned with existing piping runs.
  • Buying Guide

    Ordering the correct Wilo Top S pump parts starts with confirming the exact pump model and voltage printed on the unit's nameplate, since cartridges and control modules are not interchangeable across the full Top S lineup. Technicians should determine whether the pump uses a fixed-speed or variable-speed motor cartridge before ordering a replacement, since installing the wrong type can leave the system without proper speed control. When a pump is leaking, checking whether the failure is at the seal, the gasket, or a cracked housing helps determine whether a seal kit will resolve the issue or a full cartridge or pump replacement is needed. For control modules, confirming the communication protocol the building automation system expects prevents a mismatch between the new module and existing controls. Contractors stocking Wilo Top S pump parts for commercial service routes often keep cartridges and seal kits on hand for the pump sizes most common in their service area, since hydronic systems can fail without much warning during cold weather. Reviewing the pump's original installation documentation, when available, helps confirm the exact part numbers needed and reduces the chance of ordering an incompatible component. Replacing worn parts on a Wilo Top S pump promptly, rather than waiting for a full failure, typically costs less in labor than an emergency pump swap during peak heating season.

    Frequently Asked Questions

    Can a Wilo Top S motor cartridge be replaced without draining the whole system?

    Most Wilo Top S pumps allow the cartridge to be removed while isolating the pump with flange-mounted isolation valves, limiting water loss to the pump body itself. Systems without isolation valves will require draining before cartridge replacement. Checking for isolation valves ahead of the service call helps technicians plan the repair more efficiently.

    What typically causes a Wilo Top S pump to run noisy?

    Noise often points to air trapped in the system, a worn bearing inside the motor cartridge, or debris caught in the impeller. Bleeding air from the system is usually the first troubleshooting step before replacing any parts. Persistent grinding or humming after bleeding usually indicates a cartridge replacement is needed.

    How do I identify the correct replacement seal kit for a Wilo Top S pump?

    The pump's model number and size, found on the nameplate, determine the correct seal kit, since kits vary by pump body size. Technicians should record this information before removing the pump for service. Ordering by nameplate model number avoids fit issues with the wrong kit.

    Why would a variable-speed Wilo Top S pump stop responding to a building automation system?

    A failed or disconnected control module is a common cause, along with wiring faults at the communication terminals. Technicians should verify power and signal wiring before replacing the module. Confirming the module's communication protocol matches the automation system prevents recurring issues after replacement.

    Is it possible to upgrade a fixed-speed Wilo Top S pump to variable-speed using replacement parts?

    Fixed-speed and variable-speed Wilo Top S pumps use different motor cartridges and control architectures, so an upgrade generally requires a cartridge designed for variable-speed operation along with a compatible control module. Confirming the pump housing supports the variable-speed cartridge is an important step before ordering parts. Contractors should check manufacturer documentation to confirm compatibility before attempting the upgrade.