Apply to be a TradeMaster!
Filter menu expanded

Filters

471,048 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
471048 items
Grid
List
Compare
Product Image of 2A7A3048A1000AA Parts - Trane Central Air Conditionernot-to-sell-product
2A7A3048A1000AA Parts - Trane Central Air Conditioner
SKU: 2A7A3048A1000AA
Trane
SKU: 2A7A3048A1000AA
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2A7A8036A1000AA Parts - Trane Central Air Conditionernot-to-sell-product
2A7A8036A1000AA Parts - Trane Central Air Conditioner
SKU: 2A7A8036A1000AA
Trane
SKU: 2A7A8036A1000AA
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2A7A8036C1000AA Parts - Trane Central Air Conditionernot-to-sell-product
2A7A8036C1000AA Parts - Trane Central Air Conditioner
SKU: 2A7A8036C1000AA
Trane
SKU: 2A7A8036C1000AA
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2A7B0048A1000AA Parts - Trane Central Air Conditionernot-to-sell-product
2A7B0048A1000AA Parts - Trane Central Air Conditioner
SKU: 2A7B0048A1000AA
Trane
SKU: 2A7B0048A1000AA
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 3/4 HP Manual Effluent Pump - 115v, 50 ft Cord
$489.75 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Coil, 10t Shp, 290121R
Coil, 10t Shp, 290121R
SKU: 290121R
Nordyne
SKU: 290121R
Brand: Nordyne
$2,904.64 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 10" x 20" x 2" Polyester Throw Away Replacement Filter
$6.01 each
BOX UP & SAVE 6%
$68.04 box of 12
$5.67 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Panel, Elec, Ah, B6, 2B6401
Panel, Elec, Ah, B6, 2B6401
SKU: 2B6401
Nordyne
SKU: 2B6401
Brand: Nordyne
$10.68 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Coil, Formed, 34x75, 22fpi, R, 2B6721R
$1,217.87 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2A7C0072A3000AA Parts - Trane Central Air Conditionernot-to-sell-product
2A7C0072A3000AA Parts - Trane Central Air Conditioner
SKU: 2A7C0072A3000AA
Trane
SKU: 2A7C0072A3000AA
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2A7C2036A4000AB Parts - Trane Central Air Conditionernot-to-sell-product
2A7C2036A4000AB Parts - Trane Central Air Conditioner
SKU: 2A7C2036A4000AB
Trane
SKU: 2A7C2036A4000AB
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2A7M3030A1000AA Parts - Trane Central Air Conditionernot-to-sell-product
2A7M3030A1000AA Parts - Trane Central Air Conditioner
SKU: 2A7M3030A1000AA
Trane
SKU: 2A7M3030A1000AA
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2A7M3048A1000AA Parts - Trane Central Air Conditionernot-to-sell-product
2A7M3048A1000AA Parts - Trane Central Air Conditioner
SKU: 2A7M3048A1000AA
Trane
SKU: 2A7M3048A1000AA
Brand: Trane
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 290VAN02400AAABB Parts - Carrier Evolution Variable-Speed Heat Pumpnot-to-sell-product
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 3/4 HP Automatic Effluent Pump w/ Wide-Angle Float Switch - 115v, 10 ft Cord
$460.50 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 4" Trade Size, 50' Long, Flexible Liquidtight Conduit
$78.27 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 2865A766 Parts - Coleman Furnacenot-to-sell-product
2865A766 Parts - Coleman Furnace
SKU: 2865A766
Coleman
SKU: 2865A766
Brand: Coleman
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2865C666 Parts - Coleman Furnacenot-to-sell-product
2865C666 Parts - Coleman Furnace
SKU: 2865C666
Coleman
SKU: 2865C666
Brand: Coleman
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Top, Cabinet, M7, Top Return, 2B9881
$32.28 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Front Panel Assembly, 2A9213A01
Front Panel Assembly, 2A9213A01
SKU: 2A9213A01
Hoshizaki
SKU: 2A9213A01
Brand: Hoshizaki
$385.92 each
In Stock
Get 3 by Wed, Dec 2
In Stock
Get 3 by Wed, Dec 2
Compare
Product Image of 2AC13B60P-2A Parts - Lennox Central Air Conditionernot-to-sell-product
2AC13B60P-2A Parts - Lennox Central Air Conditioner
SKU: 2AC13B60P-2A
Lennox
SKU: 2AC13B60P-2A
Brand: Lennox
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Diverter Lever Handle Trim Kit, 2919-020-001
Diverter Lever Handle Trim Kit, 2919-020-001
SKU: 2919-020-001
Acorn
SKU: 2919-020-001
Brand: Acorn
$165.29 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Analog, DC Ammeter, Panel Meter, 2870
$183.99 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 110/125V Start Capacitor (25-30 MFD)
$4.84 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of 110/125V Start Capacitor (216-259 MFD)
110/125V Start Capacitor (216-259 MFD)
SKU: 28725-DIAL-HVAC
Dial HVAC
SKU: 28725-DIAL-HVAC
Brand: Dial HVAC
$5.83 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of Tube, Liquid, C7, C18, 2C0591
Tube, Liquid, C7, C18, 2C0591
SKU: 2C0591
Nordyne
SKU: 2C0591
Brand: Nordyne
$13.19 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Weldment, Flue, 2C2300
Weldment, Flue, 2C2300
SKU: 2C2300
Laars
SKU: 2C2300
Brand: Laars
$150.64 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Side Panel, Pump Cover, Jacket, 2C3014
Side Panel, Pump Cover, Jacket, 2C3014
SKU: 2C3014
Laars
SKU: 2C3014
Brand: Laars
$51.23 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Panel, Right Side, Jacket, 2C3520
Panel, Right Side, Jacket, 2C3520
SKU: 2C3520
Laars
SKU: 2C3520
Brand: Laars
$153.31 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 2AC13L42P-1B Parts - Lennox Central Air Conditionernot-to-sell-product
2AC13L42P-1B Parts - Lennox Central Air Conditioner
SKU: 2AC13L42P-1B
Lennox
SKU: 2AC13L42P-1B
Brand: Lennox
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 2AC13L48P-2A Parts - Lennox Central Air Conditionernot-to-sell-product
2AC13L48P-2A Parts - Lennox Central Air Conditioner
SKU: 2AC13L48P-2A
Lennox
SKU: 2AC13L48P-2A
Brand: Lennox
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Fan Motor Ac Condenser 13-seer, 2AC2011
Fan Motor Ac Condenser 13-seer, 2AC2011
SKU: 2AC2011
Crown Boiler
SKU: 2AC2011
Brand: Crown Boiler
$773.91 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 4 Cell Heat Exchanger, 2921304S
4 Cell Heat Exchanger, 2921304S
SKU: 2921304S
Goodman-Amana
SKU: 2921304S
(1)
$640.82 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 4 Cell Heat Exchanger, 2921306S
4 Cell Heat Exchanger, 2921306S
SKU: 2921306S
Goodman-Amana
SKU: 2921306S
$681.33 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Primary, Co2, for H, 2930E
Primary, Co2, for H, 2930E
SKU: 2930E
Perlick
SKU: 2930E
Brand: Perlick
$312.82 each
In Stock
Get 3 by Wed, Dec 2
In Stock
Get 3 by Wed, Dec 2
Compare
Product Image of Thermal Expansion Valve, 29311411
$439.03 each
In Stock
Get 1 by Wed, Dec 2
In Stock
Get 1 by Wed, Dec 2
Compare
Product Image of 165V Start Capacitor (108-130 MFD)
$9.62 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of 2875E966 Parts - Coleman Furnacenot-to-sell-product
2875E966 Parts - Coleman Furnace
SKU: 2875E966
Coleman
SKU: 2875E966
Brand: Coleman
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Coil Assembly, Indoor, 10t, 287821R
Coil Assembly, Indoor, 10t, 287821R
SKU: 287821R
Nordyne
SKU: 287821R
Brand: Nordyne
$1,293.66 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Panel, Jacket, Control Access, 2F3019
Panel, Jacket, Control Access, 2F3019
SKU: 2F3019
Laars
SKU: 2F3019
Brand: Laars
$89.65 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Coil, Outdoor, 2B1991R
Coil, Outdoor, 2B1991R
SKU: 2B1991R
Nordyne
SKU: 2B1991R
Brand: Nordyne
$2,920.78 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Panel, Top, D, 90, S, Uf, 2B3554R
Panel, Top, D, 90, S, Uf, 2B3554R
SKU: 2B3554R
Nordyne
SKU: 2B3554R
Brand: Nordyne
$76.80 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Thermal Expansion Valve, 29311818
$354.34 each
In Stock
Get 5 by Wed, Dec 2
In Stock
Get 5 by Wed, Dec 2
Compare
Product Image of 220/250V Start Capacitor (56-72 MFD)
$5.24 each
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Out of Stock
Get it by Tue, Dec 15 - Tue, Dec 22
Compare
Product Image of Repair Kit for 42T Traps
$221.54 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 10" x 45 FT Aluminum Liner Kit
10" x 45 FT Aluminum Liner Kit
SKU: 2GACKIT1045
Z-FLEX
SKU: 2GACKIT1045
Brand: Z-FLEX
$820.43 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Coil, Outdoor Df6se-x48-a, 2B3711R
Coil, Outdoor Df6se-x48-a, 2B3711R
SKU: 2B3711R
Nordyne
SKU: 2B3711R
Brand: Nordyne
$2,085.84 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 3/4 HP Automatic Effluent Pump w/ Wide-Angle Piggyback Float Switch - 208-230v, 25 ft Cord
$517.50 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.