Apply to be a TradeMaster!
Filter menu expanded

Filters

462,995 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
462995 items
Grid
List
Compare
Product Image of 20V MAX XR 1-1/8" SDS Plus Rotary Hammer Kit w/ Dust Extractor, DCH263R2DH
$924.08 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of FLEXVOLT 60V MAX 1-9/16" SDS Max Rotary Hammer (Tool Only), DCH481B
$715.66 each
In Stock
Get 3 by Fri, Nov 27 - Mon, Nov 30
In Stock
Get 3 by Fri, Nov 27 - Mon, Nov 30
Compare
Product Image of DGAE080CDG Parts - Coleman Furnacenot-to-sell-product
DGAE080CDG Parts - Coleman Furnace
SKU: DGAE080CDG
Coleman
SKU: DGAE080CDG
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGAT070BDD Parts - Coleman Furnacenot-to-sell-product
DGAT070BDD Parts - Coleman Furnace
SKU: DGAT070BDD
Coleman
SKU: DGAT070BDD
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80VC0603BNAD Parts - Daikin 80% AFUE Communicating Gas Furnace, Variable Speed ECM, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80VC0805DXAA Parts - Daikin 80% AFUE Communicating Gas Furnace, Variable Speed ECM, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80VC1005CNAC Parts - Daikin 80% AFUE Communicating Gas Furnace, Variable Speed ECM, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80VE0603BNAA Parts - Daikin 80% AFUE Gas Furnace, Multi Speed ECM, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80VE0803BNAA Parts - Daikin 80% AFUE Gas Furnace, Multi Speed ECM, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80SC0805CUAA Parts - Daikin 80% AFUE Gas Furnace, Variable Speed ECM, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80SE0403AX Parts - Daikin DM80HS Furnacenot-to-sell-product
DM80SE0403AX Parts - Daikin DM80HS Furnace
SKU: DM80SE0403AX
Daikin
SKU: DM80SE0403AX
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DM80SE0603AU Parts - Daikin DM80HS Furnacenot-to-sell-product
DM80SE0603AU Parts - Daikin DM80HS Furnace
SKU: DM80SE0603AU
Daikin
SKU: DM80SE0603AU
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DM80SE0604BXAA Parts - Daikin 80% AFUE Gas Furnace, Multi Speed ECM, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80SN1005CX Parts - Daikin Furnacenot-to-sell-product
DM80SN1005CX Parts - Daikin Furnace
SKU: DM80SN1005CX
Daikin
SKU: DM80SN1005CX
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DFC0367D000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC0484D000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC0603D000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC0604D000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC0903D000001SAA Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC1024D000001SAA Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGAT075BDC Parts - Coleman Furnacenot-to-sell-product
DGAT075BDC Parts - Coleman Furnace
SKU: DGAT075BDC
Coleman
SKU: DGAT075BDC
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGPA056ABTA Parts - Coleman Furnacenot-to-sell-product
DGPA056ABTA Parts - Coleman Furnace
SKU: DGPA056ABTA
Coleman
SKU: DGPA056ABTA
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGPA056ABTA/09-2000 Parts - Coleman Furnacenot-to-sell-product
DGPA056ABTA/09-2000 Parts - Coleman Furnace
SKU: DGPA056ABTA/09-2000
Coleman
SKU: DGPA056ABTA/09-2000
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGPA070ABTA/09-2000 Parts - Coleman Furnacenot-to-sell-product
DGPA070ABTA/09-2000 Parts - Coleman Furnace
SKU: DGPA070ABTA/09-2000
Coleman
SKU: DGPA070ABTA/09-2000
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGRM056AUB Parts - Coleman Furnacenot-to-sell-product
DGRM056AUB Parts - Coleman Furnace
SKU: DGRM056AUB
Coleman
SKU: DGRM056AUB
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGRM075AUA Parts - Coleman Furnacenot-to-sell-product
DGRM075AUA Parts - Coleman Furnace
SKU: DGRM075AUA
Coleman
SKU: DGRM075AUA
Brand: Coleman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80VE1205DX Parts - Daikin Furnacenot-to-sell-product
DM80VE1205DX Parts - Daikin Furnace
SKU: DM80VE1205DX
Daikin
SKU: DM80VE1205DX
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DM92SN0603BN Parts - Daikin Furnacenot-to-sell-product
DM92SN0603BN Parts - Daikin Furnace
SKU: DM92SN0603BN
Daikin
SKU: DM92SN0603BN
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DM92SN0804CNAB Parts - Daikin 92% AFUE Gas Furnace, Multi Speed ECM, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80SS0804BXAA Parts - Daikin Furnacenot-to-sell-product
DM80SS0804BXAA Parts - Daikin Furnace
SKU: DM80SS0804BXAA
Daikin
SKU: DM80SS0804BXAA
Brand: Daikin
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80TN0805CX Parts - Daikin Furnacenot-to-sell-product
DM80TN0805CX Parts - Daikin Furnace
SKU: DM80TN0805CX
Daikin
SKU: DM80TN0805CX
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DM80TN1005CNAA Parts - Daikin 80% AFUE Gas Furnace, Multi Speed ECM, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC1203D000001SAA Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC1204D000001SAA Parts - Daikin Light Commercial Packaged Air Conditionernot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC1803D000001SAA Parts - Daikin Light Commercial Packaged Air Conditioner, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC2H312J1A Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC2H324K1A Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DFC4H318K1A Parts - Heil Quaker (ICP) Heat Pumpnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGU04008UA Parts - York Furnacenot-to-sell-product
DGU04008UA Parts - York Furnace
SKU: DGU04008UA
York
SKU: DGU04008UA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGU12020UA Parts - York Furnacenot-to-sell-product
DGU12020UA Parts - York Furnace
SKU: DGU12020UA
York
SKU: DGU12020UA
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DGUC-T036N050B Parts - Packaged Unit/RTUnot-to-sell-product
DGUC-T036N050B Parts - Packaged Unit/RTU
SKU: DGUC-T036N050B
York
SKU: DGUC-T036N050B
Brand: York
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM92SS0403ANAA Parts - Daikin 92% AFUE Gas Furnace, Multi Speed ECM, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM96HS0905CXAA Parts - Daikin Furnacenot-to-sell-product
DM96HS0905CXAA Parts - Daikin Furnace
SKU: DM96HS0905CXAA
Daikin
SKU: DM96HS0905CXAA
Brand: Daikin
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM96MC1155DX Parts - Daikin Furnacenot-to-sell-product
DM96MC1155DX Parts - Daikin Furnace
SKU: DM96MC1155DX
Daikin
SKU: DM96MC1155DX
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DM96SC0603BUAC Parts - Daikin 96% AFUE Gas Furnace, Variable Speed ECM, Single Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM96SE0804CNAA Parts - Daikin 96% AFUE Gas Furnace, Multi Speed ECM, Single Stagenot-to-sell-product
DM96SE0804CNAA Parts - Daikin 96% AFUE Gas Furnace, Multi Speed ECM, Single Stage
SKU: DM96SE0804CNAA
Daikin
SKU: DM96SE0804CNAA
Brand: Daikin
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of DM80VC0804CN Parts - Daikin Furnacenot-to-sell-product
DM80VC0804CN Parts - Daikin Furnace
SKU: DM80VC0804CN
Daikin
SKU: DM80VC0804CN
Brand: Daikin
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Out of Stock
Get it by Wed, Dec 9 - Wed, Dec 16
Compare
Product Image of DM80VC0805CNAD Parts - Daikin 80% AFUE Communicating Gas Furnace, Variable Speed ECM, Two Stagenot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.