Apply to be a TradeMaster!
Filter menu expanded

Filters

460,971 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
460971 items
Grid
List
Compare
Product Image of PDV-80S-200-3N-F-PRE-NCB Parts - Power Direct Vent Independent Vent Energy Saver Gas Water Heater, NG (Front Connect, Pre New Control Box)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDV-80S-200E-3X-F-PRE-NCB Parts - Power Direct Vent Independent Vent Energy Saver Gas Water Heater, LP (Front Connect, Pre New Control Box)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDV-80S-250-3NA-T-PRE-NCB Parts - Power Direct Vent Independent Vent Energy Saver Gas Water Heater, NG (Top Connect, Pre New Control Box)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGC42B1152A/P1205414C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PGC42B1152A/P1205414C Parts - Amana Packaged Unit/RTU
SKU: PGC42B1152A/P1205414C
Goodman-Amana
SKU: PGC42B1152A/P1205414C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGD24C0702E/P1236510C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PGD24C0702E/P1236510C Parts - Amana Packaged Unit/RTU
SKU: PGD24C0702E/P1236510C
Goodman-Amana
SKU: PGD24C0702E/P1236510C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGD30C0702D/P1204304C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PGD30C0702D/P1204304C Parts - Amana Packaged Unit/RTU
SKU: PGD30C0702D/P1204304C
Goodman-Amana
SKU: PGD30C0702D/P1204304C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGF1RK072NVBA Parts - Nordyne Furnacenot-to-sell-product
PGF1RK072NVBA Parts - Nordyne Furnace
SKU: PGF1RK072NVBA
Nordyne
SKU: PGF1RK072NVBA
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGF1TA120N16C Parts - Nordyne Furnacenot-to-sell-product
PGF1TA120N16C Parts - Nordyne Furnace
SKU: PGF1TA120N16C
Nordyne
SKU: PGF1TA120N16C
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of Pulling Grip, Short Length, Rotating Eye, K-Type, 6800 Lbs Break, 7/8" Eye Dia., PH6211
$528.17 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PH8TAN56000AABAA Parts - Carrier Two-Stage Heat Pumpnot-to-sell-product
PH8TAN56000AABAA Parts - Carrier Two-Stage Heat Pump
SKU: PH8TAN56000AABAA
Carrier
SKU: PH8TAN56000AABAA
Brand: Carrier
Backorder
Get it by Tue, Feb 23 - Tue, May 18
Backorder
Get it by Tue, Feb 23 - Tue, May 18
Compare
Product Image of 1/2" x 8" Carbon Steel Pipe Hook
1/2" x 8" Carbon Steel Pipe Hook
SKU: PH9-ST128
Piers
SKU: PH9-ST128
Brand: Piers
(4)
$0.68 each
BOX UP & SAVE 13%
$29.50 box of 50
$0.59 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PDV-80S-250-3X-T-PRE-NCB Parts - Power Direct Vent Independent Vent Energy Saver Gas Water Heater, LP (Top Connect, Pre New Control Box)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDV-80S-250E-3X-F-PRE-NCB Parts - Power Direct Vent Independent Vent Energy Saver Gas Water Heater, LP (Front Connect, Pre New Control Box)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDV-80T-300-3N-F-PRE-NCB Parts - Power Direct Vent Co-Axial Vent Energy Saver Gas Water Heater, NG (Front Connection, Pre New Control Box)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDV-80T-300-3XA-F Parts - Power Direct Vent Co-Axial Vent Energy Saver Gas Water Heater, LP (Front Connection)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGD30C0902G/P1236526C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PGD30C0902G/P1236526C Parts - Amana Packaged Unit/RTU
SKU: PGD30C0902G/P1236526C
Goodman-Amana
SKU: PGD30C0902G/P1236526C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGD36C0902E/P1236507C Parts - Goodman Packaged Unit/RTUnot-to-sell-product
PGD36C0902E/P1236507C Parts - Goodman Packaged Unit/RTU
SKU: PGD36C0902E/P1236507C
Goodman
SKU: PGD36C0902E/P1236507C
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGD42C0902X/P1236533C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PGD42C0902X/P1236533C Parts - Amana Packaged Unit/RTU
SKU: PGD42C0902X/P1236533C
Goodman-Amana
SKU: PGD42C0902X/P1236533C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGF1TL110CVCA Parts - Nordyne Furnacenot-to-sell-product
PGF1TL110CVCA Parts - Nordyne Furnace
SKU: PGF1TL110CVCA
Nordyne
SKU: PGF1TL110CVCA
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGH180LFA00AAA Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHA42B0002C/P1175905C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PHA42B0002C/P1175905C Parts - Amana Packaged Unit/RTU
SKU: PHA42B0002C/P1175905C
Goodman-Amana
SKU: PHA42B0002C/P1175905C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHB30C02F1/P1239221C Parts - Goodman Packaged Unit/RTUnot-to-sell-product
PHB30C02F1/P1239221C Parts - Goodman Packaged Unit/RTU
SKU: PHB30C02F1/P1239221C
Goodman
SKU: PHB30C02F1/P1239221C
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHB30CC2E/P1228102C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PHB30CC2E/P1228102C Parts - Amana Packaged Unit/RTU
SKU: PHB30CC2E/P1228102C
Goodman-Amana
SKU: PHB30CC2E/P1228102C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDX-50S-60FB-3N-PRE-NAECA Parts - Light Duty Power Direct Vent Gas Model, NG (Pre NAECA)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDX-50S-60FC-5X-PRE-NAECA Parts - Light Duty Power Direct Vent Gas Model, LP (Pre NAECA)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDX-50S-60S-3X-PRE-FVIR Parts - Light Duty Power Direct Vent Gas Model, LP (Pre FVIR)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGD524040KTP0C1 Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGDB024G050 Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGE060LLA00AAA Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGE072LFA00AAA Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGHA060G100 Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGJ042100-1A Parts - Goodman Packaged Unit/RTUnot-to-sell-product
PGJ042100-1A Parts - Goodman Packaged Unit/RTU
SKU: PGJ042100-1A
Goodman
SKU: PGJ042100-1A
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGMD30G0904 Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGME30G0752 Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHB42C02F1/P1239223C Parts - Goodman Packaged Unit/RTUnot-to-sell-product
PHB42C02F1/P1239223C Parts - Goodman Packaged Unit/RTU
SKU: PHB42C02F1/P1239223C
Goodman
SKU: PHB42C02F1/P1239223C
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHB48C02E/P1235605C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PHB48C02E/P1235605C Parts - Amana Packaged Unit/RTU
SKU: PHB48C02E/P1235605C
Goodman-Amana
SKU: PHB48C02E/P1235605C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHB48C02E1/P1239211C Parts - Amana Packaged Unit/RTUnot-to-sell-product
PHB48C02E1/P1239211C Parts - Amana Packaged Unit/RTU
SKU: PHB48C02E1/P1239211C
Goodman-Amana
SKU: PHB48C02E1/P1239211C
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHD36C02E1/P1239714C Parts - Goodman Packaged Unit/RTUnot-to-sell-product
PHD36C02E1/P1239714C Parts - Goodman Packaged Unit/RTU
SKU: PHD36C02E1/P1239714C
Goodman
SKU: PHD36C02E1/P1239714C
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PHD36CC2F1/P1240013C Parts - Goodman Packaged Unit/RTUnot-to-sell-product
PHD36CC2F1/P1240013C Parts - Goodman Packaged Unit/RTU
SKU: PHD36CC2F1/P1240013C
Goodman
SKU: PHD36CC2F1/P1240013C
Brand: Goodman
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDX2-50T10BN-10-PRE-FVIR Parts - 48 Gallon - 60,000 BTU Residential Energy Saver Gas Power Direct Vent Water Heater, Nat Gas (Pre FVIR, Series 10)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PDX2-50T10CX-10-PRE-FVIR Parts - 48 Gallon - 60,000 BTU Residential Energy Saver Gas Power Direct Vent Water Heater, LP Gas (Pre FVIR, Series 10)not-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGE180L360AA Parts - Heil Quaker (ICP) Packaged Unit/RTUnot-to-sell-product
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of 6" 70-Degree Bent Smooth Jaw Long Nose Pliers
$19.19 each
In Stock
Get 200 by Wed, Nov 25 - Fri, Nov 27
In Stock
Get 200 by Wed, Nov 25 - Fri, Nov 27
Compare
Product Image of PGF1RA096CVBA Parts - Nordyne Furnacenot-to-sell-product
PGF1RA096CVBA Parts - Nordyne Furnace
SKU: PGF1RA096CVBA
Nordyne
SKU: PGF1RA096CVBA
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGF1TA060N08A Parts - Nordyne Furnacenot-to-sell-product
PGF1TA060N08A Parts - Nordyne Furnace
SKU: PGF1TA060N08A
Nordyne
SKU: PGF1TA060N08A
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGF1TA072C12B Parts - Nordyne Furnacenot-to-sell-product
PGF1TA072C12B Parts - Nordyne Furnace
SKU: PGF1TA072C12B
Nordyne
SKU: PGF1TA072C12B
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGF1TA072C16B Parts - Nordyne Furnacenot-to-sell-product
PGF1TA072C16B Parts - Nordyne Furnace
SKU: PGF1TA072C16B
Nordyne
SKU: PGF1TA072C16B
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Compare
Product Image of PGF1TA072CVB Parts - Nordyne Furnacenot-to-sell-product
PGF1TA072CVB Parts - Nordyne Furnace
SKU: PGF1TA072CVB
Nordyne
SKU: PGF1TA072CVB
Brand: Nordyne
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Backorder
Get it by Thu, Dec 24 - Fri, Jan 29
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.