Apply to be a TradeMaster!
Filter menu expanded

Filters

2 items
Reset

SORT

Product Availability
–

Show In Stock Only (1)

Size
–

1/2" (1)
3/4" (1)

Review Score
–

(1)

Zurn VR10 Vacuum Relief Valve

Help Face
Need a little help?
2 items
Grid
List
Compare
Product Image of 1/2" VR10 Vacuum Relief Valve MNPT(Lead Free)
1/2" VR10 Vacuum Relief Valve MNPT(Lead Free)
SKU: 12-VR10XL
Zurn
SKU: 12-VR10XL
Brand: Zurn
$68.99 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 3/4" VR10 Vacuum Relief Valve MNPT (Lead Free)
3/4" VR10 Vacuum Relief Valve MNPT (Lead Free)
SKU: 34-VR10XL
Zurn
SKU: 34-VR10XL
Brand: Zurn
(1)
$83.25 each
In Stock
Get 69 by Tomorrow, Nov 24
In Stock
Get 69 by Tomorrow, Nov 24
Resources
FAQs, Manuals & Videos
Other Resources
Articles
More About Zurn VR10 Vacuum Relief Valve

Zurn VR10 Vacuum Relief Valves are single-purpose plumbing devices that admit air into a piping system to break a vacuum condition and prevent water from being siphoned backward through a fixture or supply line. Contractors install these valves on water heater systems, boiler loops, and other closed or partially closed plumbing systems where a vacuum can form during draining, a sudden temperature drop, or a pump shutdown. Without a vacuum relief valve in place, a vacuum condition can collapse a tank, damage a heat exchanger, or draw contaminated water backward into a supply line. The VR10 line threads directly into a standard tapping on a water heater or boiler, giving contractors a straightforward retrofit option on equipment that did not ship with vacuum protection built in. Because vacuum-related tank damage is expensive to repair and can void equipment warranties, specifying the correct vacuum relief valve during installation or service is a detail worth getting right the first time.

Subcategories

  • Water Heater Applications: Zurn VR10 valves installed on residential and commercial water heaters protect the tank from vacuum collapse during draining or after a sudden cold water inrush following a hot water draw. Contractors add these valves during water heater replacement or as a standalone retrofit on an existing tank that lacks vacuum protection. Correct installation location is typically on the cold inlet side, following the tank manufacturer's specified tapping. Skipping this step on certain tank designs can void the manufacturer's warranty.
  • Boiler and Hydronic Applications: In hydronic heating systems, vacuum relief valves prevent a closed loop from drawing a vacuum when water cools and contracts after a pump shuts off or a zone valve closes unexpectedly. Contractors specify these valves on boiler loops where the system design does not already include equivalent vacuum protection elsewhere in the piping. A vacuum condition in a hydronic loop can pull air into the system through gaskets and unions, leading to noise and reduced heating performance. Placement near the highest point of the loop is common practice.
  • Threaded Connection Sizes: Zurn VR10 valves are available in the small threaded sizes typical of vacuum relief applications, matching standard tappings found on residential and light commercial water heaters and boilers. Contractors should confirm the exact thread size against the equipment's existing tapping before ordering, since a mismatch means either an adapter or a different valve. Most installations use standard pipe thread fittings and common hand tools. Checking the equipment manufacturer's installation manual confirms the correct tapping location and size.
  • Replacement and Retrofit Use: Replacing a stuck or failed vacuum relief valve is a straightforward service call, since the VR10 threads directly into the existing tapping without additional piping modification in most cases. Contractors performing water heater or boiler maintenance often inspect the existing vacuum relief valve for corrosion or a stuck mechanism as part of a routine service visit. A valve that no longer opens under vacuum conditions provides no protection even though it remains physically installed. Replacing it during other scheduled service avoids a separate trip later.
  • Buying Guide

    Specifying a Zurn VR10 Vacuum Relief Valve starts with confirming the application, since water heater installations and hydronic boiler loops call for slightly different placement even though the valve itself performs the same basic function in both settings. Matching thread size to the existing tapping on the tank or boiler comes next, since a mismatched connection means sourcing an adapter or choosing a different valve entirely rather than forcing an incompatible fitting. For new equipment installations, checking the manufacturer's installation manual confirms whether a vacuum relief valve is required, recommended, or already built into the unit, since some water heaters and boilers ship with equivalent protection factory-installed. For retrofit and service calls, inspecting an existing vacuum relief valve for corrosion, mineral buildup, or a stuck mechanism is worth doing anytime a contractor is already working on the equipment, since a valve that looks intact from the outside can still fail to open under an actual vacuum condition. Because vacuum-related damage to a tank or heat exchanger is often not covered under a manufacturer's warranty once traced back to a missing or failed relief valve, contractors should treat the Zurn VR10 Vacuum Relief Valve as cheap insurance relative to the cost of the equipment it protects. Confirming local plumbing code requirements before a new installation is also worth doing, since some jurisdictions specify vacuum relief requirements on certain water heater types.

    Frequently Asked Questions

    What does a vacuum relief valve actually do?

    A vacuum relief valve opens to let air into a plumbing or hydronic system whenever internal pressure drops below atmospheric pressure, breaking the vacuum before it can collapse a tank or pull water backward through a fixture. Without one, a vacuum condition can damage a water heater tank or draw contaminated water into a supply line. The valve stays closed under normal operating pressure and only opens when a vacuum actually forms.

    Where should a Zurn VR10 valve be installed on a water heater?

    Placement typically follows the tank manufacturer's specified tapping, most often on the cold water inlet side of the tank. Checking the installation manual for the specific water heater model confirms the correct location before drilling or tapping a new opening. Installing it in the wrong location can reduce its effectiveness at protecting the tank.

    Can a vacuum relief valve fail without looking obviously broken?

    Yes, corrosion or mineral buildup inside the valve can prevent it from opening under vacuum conditions even though the valve looks intact from the outside. Testing or replacing an aging vacuum relief valve during other scheduled service on the same equipment is a reasonable precaution. A valve that no longer functions provides no actual protection despite still being physically installed.

    Is a vacuum relief valve required by code?

    Requirements vary by jurisdiction and by the type of water heater or boiler being installed, so checking local plumbing code before a new installation is worth the extra step. Some equipment manufacturers also specify vacuum relief protection as a warranty condition regardless of local code. Confirming both code and manufacturer requirements avoids a comeback inspection failure.

    Does a vacuum relief valve replace other water heater safety devices?

    No, a vacuum relief valve serves a different function than a temperature and pressure relief valve, and installing one does not eliminate the need for the other. Each device protects against a different failure mode, vacuum collapse versus overpressure and overtemperature. Both are typically required for a complete, code-compliant water heater installation.

Didn't find what you're looking for? 
Let us know
.