Specs

Connection Size: 1/4"
Connection Type: Threaded
Accessory For: EG Boilers
EGH Boilers
68 Boilers
PFG Boilers

Description for Weil Mclain 510-218-097

Weil McLain combination pressure-temperature gauge for boiler models (sizes 85-125):

  • EG
  • EGH
  • 68
  • PFG
Product Details:
  • 0-60 P.S.I.G.
  • Long shank
  • 2-1/2" dial
  • 1/4" N.P.T
  • Back connection

Combination Pressure-Temperature Gauge (Boiler Sizes 85-125)

REVIEW SNAPSHOT®

by PowerReviews
Weil MclainCombination Pressure-Temperature Gauge (Boiler Sizes 85-125)
 
4.0

(based on 4 reviews)

Ratings Distribution

  • 5 Stars

     

    (3)

  • 4 Stars

     

    (0)

  • 3 Stars

     

    (0)

  • 2 Stars

     

    (0)

  • 1 Stars

     

    (1)

75%

of respondents would recommend this to a friend.

Pros

    Cons

      Best Uses

          • Primary use:
          • Personal (3)

        Reviewed by 4 customers

        Sort by

        Displaying reviews 1-4

        Back to top

         
        5.0

        Quality product

        By Techie

        from Kankakee, IL

        Verified Buyer

        Pros

          Cons

            Best Uses

              Comments about Combination Pressure-Temperature Gauge (Boiler Sizes 85-125):

              I have installed this gauge on my Weil McClain boiler, to replace one that stopped working. The stem is longer than needed, but it fit okay and is working properly.

              • Primary use:
              • Personal
               
              5.0

              Works great

              By mrfixit

              from New Haven, CT

              Verified Buyer

              Pros

                Cons

                  Best Uses

                    Comments about Combination Pressure-Temperature Gauge (Boiler Sizes 85-125):

                    Installation was a breeze. Seemed to have some moisture within the gauge that went away after a couple of days. With a good working gauge I now know that my triple Aquastat is working properly saving me some cash. This place ships fast.

                    • Primary use:
                    • Personal

                    (0 of 1 customers found this review helpful)

                     
                    1.0

                    poor quality

                    By skidstir

                    from Illinois

                    Verified Buyer

                    Pros

                      Cons

                        Best Uses

                          Comments about Combination Pressure-Temperature Gauge (Boiler Sizes 85-125):

                          the pressure gauge is will not go below 20 psi, which is pointless in my situation where I need only 12 psi. I think the temp. gauge is fine though.

                          • Primary use:
                          • Business
                           
                          5.0

                          Biggest Bang for the Buck!

                          By Fred the Searcher

                          from Chicago, IL

                          Verified Buyer

                          Pros

                            Cons

                              Best Uses

                                Comments about Combination Pressure-Temperature Gauge (Boiler Sizes 85-125):

                                I searched on line extensively for a repalcement for the temperaure and pressure guage that had failed. I found it here for a great price and quick delivery. It was easy to install and am very happy to read boiler temperature and pressure again.

                                • Primary use:
                                • Personal

                                Displaying reviews 1-4

                                Back to top

                                Q&A: Ask the Questions, share answers

                                Do you have questions about this product?

                                get answers from real customers and in-house experts with AnswerBox.

                                5 Questions | 8 Answers
                                Displaying questions 1-5
                                • Combination Pressure-Temperature Gauge (Boiler Sizes 85-125)

                                  Q:

                                  I have a Weil McLain model PCG-5
                                  output 112,000 btu
                                  Will this guage work on my furnace ? the long stem and 2 1/2" face is important.
                                  thank you
                                  dave travis
                                  Asked on 5/9/2012 by dave from taylor, mi.

                                  3 answers

                                  • CUSTOMER CARE

                                    A:

                                    510-218-097 is the pressure temp gauge for the EGH 85-125 and yes, it should fit the PCG-5 Boiler.

                                    Answered on 6/7/2012 by PexSupply Staff from NY
                                  • VERIFIED BUYER

                                    A:

                                    Hi,  I purchased the same for my Weil McLain HE2.   While it was NOT an OEM part (to my surprise), it fit my boiler perfectly and has operated without issue for about 2 years.  The neck/ stem on the gauge was about an inch or so longer than the original part.  This has had no impact on the operation of the replacement part.   I believe this will work fine on most other Weil McLain boilers.

                                    Answered on 5/9/2012 by Another PexSupply Customer
                                  • VERIFIED BUYER

                                    A:

                                    Dave,
                                    My PCG-5 furnace requires the short version as originally supplied but I
                                    ordered the longer version (really by mistake) and it works just fine. It
                                    just sticks out a little further. Make sure that you have enough room (about
                                    3.5 ins.) to install it.
                                    Fred Budelman

                                    Answered on 5/10/2012 by Anonymous
                                • Combination Pressure-Temperature Gauge (Boiler Sizes 85-125)

                                  Q:

                                  How do you read the pressure portion? What's the little red arrow and what is the black one?
                                  Asked on 5/9/2011 by Anonymous

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    The black arrow notes the pressure reading. The red arrow can be turned anywhere on the dial by the user as a reference point for temperature or pressure.

                                    Answered on 5/9/2011 by PexSupply Staff from NY
                                • Combination Pressure-Temperature Gauge (Boiler Sizes 85-125)

                                  Q:

                                  DOES THE BOILER BE DRAINED TO INSTALL PRESSURE-TEMPERATURE GAUGE?
                                  Asked on 12/6/2010 by DON from CT

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    Yes.

                                    Answered on 12/6/2010 by PexSupply Staff from NY
                                • Combination Pressure-Temperature Gauge (Boiler Sizes 85-125)

                                  Q:

                                  My gauge stared leaking at the back of gauge a couple of days ago. It was installed a year ago. I don't what is wrong with it. How do I fix it? Thanks
                                  Asked on 11/30/2010 by Zee from Seattle

                                  1 answer

                                  • CUSTOMER CARE

                                    A:

                                    You should check to make sure that the gauge is not leaking from where it is threaded into the boiler/pipe. If this is the case, you may need to tighten it. If that is not the case, then you will need to replace the unit.

                                    Answered on 12/2/2010 by PexSupply Staff from NY
                                • Combination Pressure-Temperature Gauge (Boiler Sizes 85-125)

                                  Q:

                                  I have a weil mclain model#P-468-wt boiler D.O.E. 151,000 will this pressure-temperature guage fit?
                                  Asked on 9/24/2010 by sandy from boston

                                  2 answers

                                  • CUSTOMER CARE

                                    A:

                                    The tapping size of the P-468 is 1/4". This pressure-temperature gauge has 1/4" threads and would screw right in. So yes this gaue would work on the P-468.

                                    Answered on 9/29/2010 by PexSupply Staff from NY
                                  • CUSTOMER CARE

                                    A:

                                    Yes, this gauge would work for the P-468 boiler. The tapping size of the P-468 is 1/4" and this gauge has 1/4" threads, so it would screw right in.

                                    Answered on 10/1/2010 by PexSupply Staff from NY
                                Displaying questions 1-5