Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Control Board, 14B0036N21
Control Board, 14B0036N21
SKU: 14B0036N21
ClimateMaster
SKU: 14B0036N21
$589.03 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 1" Swt Motorized Valve, AVMB5
$362.13 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of 20kw Electric Heater, AH20GL
$1,278.17 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Chassis, TRM24G1KMCSA
Chassis, TRM24G1KMCSA
SKU: TRM24G1KMCSA
ClimateMaster
SKU: TRM24G1KMCSA
$5,219.55 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 208/230v 1 Ph R22 31300 Btu Comp, 68832737S
$2,832.37 each
Out of Stock
Get it by Mon, Oct 19 - Wed, Oct 28
Out of Stock
Get it by Mon, Oct 19 - Wed, Oct 28
Compare
Product Image of Deck Kit, 79S0040N02
Deck Kit, 79S0040N02
SKU: 79S0040N02
ClimateMaster
SKU: 79S0040N02
$1,003.57 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 1/2 Service Valve, 33B0003N02
1/2 Service Valve, 33B0003N02
SKU: 33B0003N02
ClimateMaster
SKU: 33B0003N02
$95.33 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Replacement Cartridge Taco Pump, ACP0013-C3
$177.85 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coil, 62B0013N02
Coil, 62B0013N02
SKU: 62B0013N02
ClimateMaster
SKU: 62B0013N02
$4,595.16 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor Plate, 47S0531GNN
Compressor Plate, 47S0531GNN
SKU: 47S0531GNN
ClimateMaster
SKU: 47S0531GNN
$49.61 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Controller, 14B0036N18
Controller, 14B0036N18
SKU: 14B0036N18
ClimateMaster
SKU: 14B0036N18
$580.32 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Actuator Valve, 23B0012N05
Actuator Valve, 23B0012N05
SKU: 23B0012N05
ClimateMaster
SKU: 23B0012N05
$115.65 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Suction Pressure Sensor, 426-025
$315.91 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 10kw 240v 1ph Duct Heater, AH10GM
$874.29 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Controller, 14B0036N16
Controller, 14B0036N16
SKU: 14B0036N16
ClimateMaster
SKU: 14B0036N16
$454.66 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Bracket Horiz Btm Hanger, 710031N01
$2.72 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 20kw 240v Duct Heater, AGL20CAG
$925.25 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Capacitor, 15B0013N39
Capacitor, 15B0013N39
SKU: 15B0013N39
ClimateMaster
SKU: 15B0013N39
$53.88 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor Replacement Kit, S34B0025N02
$1,481.66 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Coax, 62C0040N31
Coax, 62C0040N31
SKU: 62C0040N31
ClimateMaster
SKU: 62C0040N31
$476.18 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Cooling Coil 36x42, 61B0329N01
Air Cooling Coil 36x42, 61B0329N01
SKU: 61B0329N01
ClimateMaster
SKU: 61B0329N01
$1,929.90 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 230v1ph Compressor, 34B0068N01
230v1ph Compressor, 34B0068N01
SKU: 34B0068N01
ClimateMaster
SKU: 34B0068N01
$1,118.36 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Wall Mount Room Sensor w/ cover, ASW021STN
$207.04 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Flow Sensor, 17B0078N01
Flow Sensor, 17B0078N01
SKU: 17B0078N01
ClimateMaster
SKU: 17B0078N01
$617.62 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0132N03
Compressor, 34B0132N03
SKU: 34B0132N03
ClimateMaster
SKU: 34B0132N03
$1,349.27 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 34B0027N01S
Compressor, 34B0027N01S
SKU: 34B0027N01S
ClimateMaster
SKU: 34B0027N01S
$1,697.29 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Control Board, 17B0039N01
Control Board, 17B0039N01
SKU: 17B0039N01
ClimateMaster
SKU: 17B0039N01
$398.13 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 265v1ph Compressor, 34K0013N12
265v1ph Compressor, 34K0013N12
SKU: 34K0013N12
ClimateMaster
SKU: 34K0013N12
$506.64 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 18k Heat Pump Console, TRC18BGNASNCGRS
18k Heat Pump Console, TRC18BGNASNCGRS
SKU: TRC18BGNASNCGRS
ClimateMaster
SKU: TRC18BGNASNCGRS
$4,733.29 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Rocker Switch, 13B0026N01
Rocker Switch, 13B0026N01
SKU: 13B0026N01
ClimateMaster
SKU: 13B0026N01
$131.85 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Icm Control Assembly, S14S0016N22
Icm Control Assembly, S14S0016N22
SKU: S14S0016N22
ClimateMaster
SKU: S14S0016N22
$612.98 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 230v1ph 41,200btu R410a Comp, S34P0164N01
$7,226.19 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Expansion Valve, 33B0001N02
Expansion Valve, 33B0001N02
SKU: 33B0001N02
ClimateMaster
SKU: 33B0001N02
$167.80 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Tsm12 Chassis Only, TSM12GSBFMLSSSB
Tsm12 Chassis Only, TSM12GSBFMLSSSB
SKU: TSM12GSBFMLSSSB
ClimateMaster
SKU: TSM12GSBFMLSSSB
$3,044.69 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Eec Assembly, S33S0197N04
Eec Assembly, S33S0197N04
SKU: S33S0197N04
ClimateMaster
SKU: S33S0197N04
$663.56 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of K060 Copper Coax, 62C0046N01
K060 Copper Coax, 62C0046N01
SKU: 62C0046N01
ClimateMaster
SKU: 62C0046N01
$1,345.22 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Air Coil, 61B0403N01
Air Coil, 61B0403N01
SKU: 61B0403N01
ClimateMaster
SKU: 61B0403N01
$1,288.60 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of TXV Powerhead Replacement Kit, S33S0002N90
$14.95 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Coil Tin/coated, 61B0242N70
Air Coil Tin/coated, 61B0242N70
SKU: 61B0242N70
ClimateMaster
SKU: 61B0242N70
$1,297.25 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 34B0068N04
Compressor, 34B0068N04
SKU: 34B0068N04
ClimateMaster
SKU: 34B0068N04
$1,238.87 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Valve Core, 39B0002N02
Valve Core, 39B0002N02
SKU: 39B0002N02
ClimateMaster
SKU: 39B0002N02
$8.51 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Inductor, 15B0015N01
Inductor, 15B0015N01
SKU: 15B0015N01
ClimateMaster
SKU: 15B0015N01
$682.55 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Flow Controller Single Pump, AFCG1C1
$1,476.23 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Housing, 73B0001N01
Blower Housing, 73B0001N01
SKU: 73B0001N01
ClimateMaster
SKU: 73B0001N01
$263.67 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Coil, 61B0248N70
Air Coil, 61B0248N70
SKU: 61B0248N70
ClimateMaster
SKU: 61B0248N70
$1,035.83 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 34B0131N02
Compressor, 34B0131N02
SKU: 34B0131N02
ClimateMaster
SKU: 34B0131N02
$1,114.54 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 2 1/2" X 2' Hose Kit, AHK2502
$947.00 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Climatemaster Motor, S14S0019N31
Climatemaster Motor, S14S0019N31
SKU: S14S0019N31
ClimateMaster
SKU: S14S0019N31
$929.99 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.