Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Flow Valve Regulator, 23B0030N06
Flow Valve Regulator, 23B0030N06
SKU: 23B0030N06
ClimateMaster
SKU: 23B0030N06
$125.25 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 1-1/4 Gasket, 29B0018N04
1-1/4 Gasket, 29B0018N04
SKU: 29B0018N04
ClimateMaster
SKU: 29B0018N04
$8.47 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Drain Pain, 49S0292ANP
Drain Pain, 49S0292ANP
SKU: 49S0292ANP
ClimateMaster
SKU: 49S0292ANP
$184.94 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 230v3ph R410a Scroll Compressor, 34B0133N02
$1,495.17 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of 460v 3 Ph 41700 Btu R22, 34B0027N03S
460v 3 Ph 41700 Btu R22, 34B0027N03S
SKU: 34B0027N03S
ClimateMaster
SKU: 34B0027N03S
$1,985.44 each
Out of Stock
Get it by Tue, Oct 20 - Thu, Oct 29
Out of Stock
Get it by Tue, Oct 20 - Thu, Oct 29
Compare
Product Image of 265v 1ph Compressor, 34B0107N02
265v 1ph Compressor, 34B0107N02
SKU: 34B0107N02
ClimateMaster
SKU: 34B0107N02
$348.10 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Wxm Board, 17B0051N01
Wxm Board, 17B0051N01
SKU: 17B0051N01
ClimateMaster
SKU: 17B0051N01
$232.03 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 3mfd 370v Oval Run Capacitor, 15B0013N01
$19.32 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Compressor Hga 208-230/60/1, 34B0048N01
$430.19 each
Out of Stock
Get it by Mon, Oct 19 - Mon, Oct 26
Out of Stock
Get it by Mon, Oct 19 - Mon, Oct 26
Compare
Product Image of Rail Roof Long Tre096-240, 47F1342GNN
$52.43 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Ari Coil 16x16 3r Tin Plated, 61B0215N70
$1,188.12 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Compressor Overload, 16B0009N25
Compressor Overload, 16B0009N25
SKU: 16B0009N25
ClimateMaster
SKU: 16B0009N25
$22.67 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Disconnect Switch, 13B0030N03
Disconnect Switch, 13B0030N03
SKU: 13B0030N03
ClimateMaster
SKU: 13B0030N03
$489.09 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Compressor Replacment Kit, S34P0165N03
$2,142.02 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Harness Magna Controller, 11B0020N01
$21.27 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Panel Filter Door, 46F0645GNB
Panel Filter Door, 46F0645GNB
SKU: 46F0645GNB
ClimateMaster
SKU: 46F0645GNB
$35.46 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Filter Rack, S40S0102GNB
Filter Rack, S40S0102GNB
SKU: S40S0102GNB
ClimateMaster
SKU: S40S0102GNB
$142.85 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 4 Ton Bleed 15% TXV Valve, 33B0001N05
$274.90 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Tsm18 Chassis Only, TSM18GSBHMC6SSB
Tsm18 Chassis Only, TSM18GSBHMC6SSB
SKU: TSM18GSBHMC6SSB
ClimateMaster
SKU: TSM18GSBHMC6SSB
$4,327.41 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Valve Flow Reg 5gpm, 23B0005N17
Valve Flow Reg 5gpm, 23B0005N17
SKU: 23B0005N17
ClimateMaster
SKU: 23B0005N17
$229.36 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Coax Coil, 62C0016N01
Coax Coil, 62C0016N01
SKU: 62C0016N01
ClimateMaster
SKU: 62C0016N01
$719.95 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Coil Assembly, 61B0015N02
Coil Assembly, 61B0015N02
SKU: 61B0015N02
ClimateMaster
SKU: 61B0015N02
$1,180.51 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of 8kw 240v Duct Heater, AGM08CAG
$634.44 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of ECM Motor Assembly, S14S0039N01
ECM Motor Assembly, S14S0039N01
SKU: S14S0039N01
ClimateMaster
SKU: S14S0039N01
$1,157.11 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Climate Master Coax, 62C0092N01
Climate Master Coax, 62C0092N01
SKU: 62C0092N01
ClimateMaster
SKU: 62C0092N01
$695.27 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 208v 1ph Compressor, 34B0144N01
208v 1ph Compressor, 34B0144N01
SKU: 34B0144N01
ClimateMaster
SKU: 34B0144N01
$1,473.85 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Air Coil, 61B0500N01
Air Coil, 61B0500N01
SKU: 61B0500N01
ClimateMaster
SKU: 61B0500N01
$1,467.40 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of TXV, 33B0058N05
TXV, 33B0058N05
SKU: 33B0058N05
ClimateMaster
SKU: 33B0058N05
$201.69 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Primary Valve Kit, S30S0172N01
Primary Valve Kit, S30S0172N01
SKU: S30S0172N01
ClimateMaster
SKU: S30S0172N01
$222.77 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Dsa/muffler Asm, S33S0120N03
Dsa/muffler Asm, S33S0120N03
SKU: S33S0120N03
ClimateMaster
SKU: S33S0120N03
$345.09 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Compressor, 34B0069N02
Compressor, 34B0069N02
SKU: 34B0069N02
ClimateMaster
SKU: 34B0069N02
$1,025.72 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Icm Blower Motor, S14S0009N02
Icm Blower Motor, S14S0009N02
SKU: S14S0009N02
ClimateMaster
SKU: S14S0009N02
$969.75 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Transformer, 15B0017N02
Transformer, 15B0017N02
SKU: 15B0017N02
ClimateMaster
SKU: 15B0017N02
$111.99 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Brass Flow Controller, AFCG2B1
$2,563.35 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Evap Coil, 61B0179N01
Evap Coil, 61B0179N01
SKU: 61B0179N01
ClimateMaster
SKU: 61B0179N01
$1,122.20 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Cabinet Deck Kit, 79S0040N40
Cabinet Deck Kit, 79S0040N40
SKU: 79S0040N40
ClimateMaster
SKU: 79S0040N40
$844.80 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Blower Assembly w/ wheel, 73B0004N02
$537.89 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Motor, 14S0014N04
Motor, 14S0014N04
SKU: 14S0014N04
ClimateMaster
SKU: 14S0014N04
$487.79 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Compressor, 34B0060N01
Compressor, 34B0060N01
SKU: 34B0060N01
ClimateMaster
SKU: 34B0060N01
$1,343.05 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Flush Cam Adapter, AFC7C
$340.99 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Capacitor, 15B0013N32
Capacitor, 15B0013N32
SKU: 15B0013N32
ClimateMaster
SKU: 15B0013N32
$45.91 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Air Coil, 61B0275N01
Air Coil, 61B0275N01
SKU: 61B0275N01
ClimateMaster
SKU: 61B0275N01
$2,498.94 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Compressor, 34B0131N04
Compressor, 34B0131N04
SKU: 34B0131N04
ClimateMaster
SKU: 34B0131N04
$1,337.85 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Access Panel, 41F0492GBS
Access Panel, 41F0492GBS
SKU: 41F0492GBS
ClimateMaster
SKU: 41F0492GBS
$99.24 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Programmed Motor Assembly, S14S0020N05
$867.75 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Harness, 11B0002N05
Harness, 11B0002N05
SKU: 11B0002N05
ClimateMaster
SKU: 11B0002N05
$21.27 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Motorized Valve 1 1/2" w/ end, 23B0041N01
$1,162.19 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 2 Gasket, 29B0018N06
2 Gasket, 29B0018N06
SKU: 29B0018N06
ClimateMaster
SKU: 29B0018N06
$9.94 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.