Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Expansion Valve, 33B0051N04
Expansion Valve, 33B0051N04
SKU: 33B0051N04
ClimateMaster
SKU: 33B0051N04
$527.08 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Tev064 Wrapper Rear Back Panel, 44F0920GBB
$406.96 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Evap Coil, 61B009N70
Evap Coil, 61B009N70
SKU: 61B009N70
ClimateMaster
SKU: 61B009N70
$1,591.56 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Vacuum Relief Valve, 29B0203N02
Vacuum Relief Valve, 29B0203N02
SKU: 29B0203N02
ClimateMaster
SKU: 29B0203N02
$220.42 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Drain Pan, 49F0370SNN
Drain Pan, 49F0370SNN
SKU: 49F0370SNN
ClimateMaster
SKU: 49F0370SNN
$104.90 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Side Panel Qev093, 41F0901GBB
Side Panel Qev093, 41F0901GBB
SKU: 41F0901GBB
ClimateMaster
SKU: 41F0901GBB
$243.89 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Label Installer Instruction, 95B0005N02
$6.80 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Drain Pan Assembly, 49S0380GAP
Drain Pan Assembly, 49S0380GAP
SKU: 49S0380GAP
ClimateMaster
SKU: 49S0380GAP
$78.33 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 1/2" X 2' Hose Kit, AHK0502
$81.48 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Compressor, 34B0137N01
Compressor, 34B0137N01
SKU: 34B0137N01
ClimateMaster
SKU: 34B0137N01
$1,148.79 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of 40mfd 370v Capacitor, 15B0013N14
40mfd 370v Capacitor, 15B0013N14
SKU: 15B0013N14
ClimateMaster
SKU: 15B0013N14
$22.68 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Coax Cover Side B, 62I0009N12
Coax Cover Side B, 62I0009N12
SKU: 62I0009N12
ClimateMaster
SKU: 62I0009N12
$99.23 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Compressor, 34B0031N01S
Compressor, 34B0031N01S
SKU: 34B0031N01S
ClimateMaster
SKU: 34B0031N01S
$1,450.77 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Compressor, 34B0099N08
Compressor, 34B0099N08
SKU: 34B0099N08
ClimateMaster
SKU: 34B0099N08
$1,165.29 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Compressor, 34B0051N02S
Compressor, 34B0051N02S
SKU: 34B0051N02S
ClimateMaster
SKU: 34B0051N02S
$7,289.27 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of TXV Thermal Expansion Valve, 33B0019N09
$588.09 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Sensor, 17B0030N07
Sensor, 17B0030N07
SKU: 17B0030N07
ClimateMaster
SKU: 17B0030N07
$51.69 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 265v1ph R410a Compressor, 34B0108N02
$804.38 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Air Coil, 61S0111N55
Air Coil, 61S0111N55
SKU: 61S0111N55
ClimateMaster
SKU: 61S0111N55
$1,444.53 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Blower Assembly, S70S0006N04
Blower Assembly, S70S0006N04
SKU: S70S0006N04
ClimateMaster
SKU: S70S0006N04
$959.16 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 230v1ph R22 15500btu Rot Compressor, 34B0073N01
$856.00 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Hose Adapters, 290019N08
Hose Adapters, 290019N08
SKU: 290019N08
ClimateMaster
SKU: 290019N08
$142.59 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Cm Pump Ump2, 24B0022N01
Cm Pump Ump2, 24B0022N01
SKU: 24B0022N01
ClimateMaster
SKU: 24B0022N01
$1,054.34 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of High Level Cond Sens, S69660900
High Level Cond Sens, S69660900
SKU: S69660900
ClimateMaster
SKU: S69660900
$46.50 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Touch Up Paint (ttv), 54B0007N01
Touch Up Paint (ttv), 54B0007N01
SKU: 54B0007N01
ClimateMaster
SKU: 54B0007N01
$175.20 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Exm Control Board, 17B0055N04
Exm Control Board, 17B0055N04
SKU: 17B0055N04
ClimateMaster
SKU: 17B0055N04
$1,599.82 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 208-230v1ph R22 11,500btu Compressor, 34K0115N01
$560.96 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Hwg Hose Adapter, 29B0013N04
Hwg Hose Adapter, 29B0013N04
SKU: 29B0013N04
ClimateMaster
SKU: 29B0013N04
$31.02 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Commercial Thermostat, ATP32U04C
$356.88 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Seat 3/8" Hole Saddle Coremax, 39B0019N02
$11.33 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Wrapper-compr, 44F3510GFB
Wrapper-compr, 44F3510GFB
SKU: 44F3510GFB
ClimateMaster
SKU: 44F3510GFB
$138.41 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Gas Bypass Valve, 33B0046N02
Gas Bypass Valve, 33B0046N02
SKU: 33B0046N02
ClimateMaster
SKU: 33B0046N02
$563.33 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Transition Bracket Tzv036-042, 47F1746GNN
$29.80 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Actuators, 23B0085N02
Actuators, 23B0085N02
SKU: 23B0085N02
ClimateMaster
SKU: 23B0085N02
$1,552.92 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Muffler, 36B0006N07
Muffler, 36B0006N07
SKU: 36B0006N07
ClimateMaster
SKU: 36B0006N07
$46.79 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 21" Cased Air Coil, TAC038BM21S
21" Cased Air Coil, TAC038BM21S
SKU: TAC038BM21S
ClimateMaster
SKU: TAC038BM21S
$1,886.58 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of TXV Valve, 33B0027N01
TXV Valve, 33B0027N01
SKU: 33B0027N01
ClimateMaster
SKU: 33B0027N01
$169.81 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 24v On/off Actuator, 23B0105N01
24v On/off Actuator, 23B0105N01
SKU: 23B0105N01
ClimateMaster
SKU: 23B0105N01
$317.78 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 18x20" Evap Coil, 61B0112N01
18x20" Evap Coil, 61B0112N01
SKU: 61B0112N01
ClimateMaster
SKU: 61B0112N01
$1,029.47 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Hose Kit Assembly, AHA0752
$232.43 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 1/2" Hose Kit, AHS0502
1/2" Hose Kit, AHS0502
SKU: AHS0502
ClimateMaster
SKU: AHS0502
$189.68 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 20 Kw Heater Element, 18B0008N01
20 Kw Heater Element, 18B0008N01
SKU: 18B0008N01
ClimateMaster
SKU: 18B0008N01
$216.21 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Harness ECM Motor, S11S0001N01
Harness ECM Motor, S11S0001N01
SKU: S11S0001N01
ClimateMaster
SKU: S11S0001N01
$92.11 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Coil 36x48 4 Row Assembly, 61B0234N01
$3,478.87 each
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Backorder
Get it by Tue, Nov 3 - Fri, Dec 4
Compare
Product Image of Belt Material Price Per Foot, 696-005
$418.36 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Aws Upper Element Thermostat, 29B0203N05
$100.57 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of 5kw 460v 3ph Duct Heater, AH05FS
$528.57 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Compare
Product Image of Front Panel, 41F0302GRP
Front Panel, 41F0302GRP
SKU: 41F0302GRP
ClimateMaster
SKU: 41F0302GRP
$212.26 each
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Backorder
Get it by Mon, Nov 2 - Tue, Dec 1
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.