Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Flow Module Ups32-160 230v 1ph, AFCG1B3
$4,651.94 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0130N04
Compressor, 34B0130N04
SKU: 34B0130N04
ClimateMaster
SKU: 34B0130N04
$1,297.23 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 1 1/2" X 2' Hose Kit, AHK1502
$479.58 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of ECM Motor Assembly w/ controller, S14S0019N29
$930.00 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Ball Valve / Union Assembly, 23B0016N06
$76.55 each
In Stock
Get 1 by Mon, Oct 5
In Stock
Get 1 by Mon, Oct 5
Compare
Product Image of Magna Pump Assembly, S23S0078N01
Magna Pump Assembly, S23S0078N01
SKU: S23S0078N01
ClimateMaster
SKU: S23S0078N01
$2,496.31 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Drain Pan, 49S0126GFP
Drain Pan, 49S0126GFP
SKU: 49S0126GFP
ClimateMaster
SKU: 49S0126GFP
$110.57 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0101N07
Compressor, 34B0101N07
SKU: 34B0101N07
ClimateMaster
SKU: 34B0101N07
$3,140.33 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Chassis, TRM36G1NMCSA
Chassis, TRM36G1NMCSA
SKU: TRM36G1NMCSA
ClimateMaster
SKU: TRM36G1NMCSA
$5,539.39 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Sensor Kit Black Tac/h, S17S0031N12
Sensor Kit Black Tac/h, S17S0031N12
SKU: S17S0031N12
ClimateMaster
SKU: S17S0031N12
$123.63 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Exhaust Blower Motor, 720-126
$3,261.14 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Subbase, S83P0263N01
Subbase, S83P0263N01
SKU: S83P0263N01
ClimateMaster
SKU: S83P0263N01
$294.79 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Rear Wrapper, 44F0329GFB
Rear Wrapper, 44F0329GFB
SKU: 44F0329GFB
ClimateMaster
SKU: 44F0329GFB
$204.38 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 1/15 3 speed 4p Motor, 14B0018N01
1/15 3 speed 4p Motor, 14B0018N01
SKU: 14B0018N01
ClimateMaster
SKU: 14B0018N01
$135.24 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 15kw Electric Heater, AH15HM
$1,227.25 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Control Board, 17B0024N02
Control Board, 17B0024N02
SKU: 17B0024N02
ClimateMaster
SKU: 17B0024N02
$1,210.39 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Cabinet Kit, 79S0040N05
Cabinet Kit, 79S0040N05
SKU: 79S0040N05
ClimateMaster
SKU: 79S0040N05
$624.05 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0053N01
Compressor, 34B0053N01
SKU: 34B0053N01
ClimateMaster
SKU: 34B0053N01
$3,308.71 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of L1034-b6ji Pump, 24B0036N01
L1034-b6ji Pump, 24B0036N01
SKU: 24B0036N01
ClimateMaster
SKU: 24B0036N01
$547.71 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 10x15 2r Evap Coil, 61B0098N01
10x15 2r Evap Coil, 61B0098N01
SKU: 61B0098N01
ClimateMaster
SKU: 61B0098N01
$430.40 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Sleeve, 29B0073N01
Sleeve, 29B0073N01
SKU: 29B0073N01
ClimateMaster
SKU: 29B0073N01
$11.33 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Emblem Earth Pure, 95B0001N12
Emblem Earth Pure, 95B0001N12
SKU: 95B0001N12
ClimateMaster
SKU: 95B0001N12
$16.30 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Control Board, 17S0012N10
Control Board, 17S0012N10
SKU: 17S0012N10
ClimateMaster
SKU: 17S0012N10
$1,285.41 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Expansion Valve, 33B0020N08
Expansion Valve, 33B0020N08
SKU: 33B0020N08
ClimateMaster
SKU: 33B0020N08
$171.38 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Wire Harness, 11B0010N01
Wire Harness, 11B0010N01
SKU: 11B0010N01
ClimateMaster
SKU: 11B0010N01
$19.84 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Overload, 115-045
Overload, 115-045
SKU: 115-045
ClimateMaster
SKU: 115-045
$237.66 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 208/230-1ph R22 20,000btu Comp, 34B0043N01S
$2,061.04 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Flow Controller Dbl Pump Ups32, AFCG2B3
$7,804.75 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 3/4" Ball Valve w/ memory Stop, ABV075MP
$89.95 each
In Stock
Get 5 by Mon, Oct 5
In Stock
Get 5 by Mon, Oct 5
Compare
Product Image of White Sensor, 17B0030N10
White Sensor, 17B0030N10
SKU: 17B0030N10
ClimateMaster
SKU: 17B0030N10
$43.95 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 7.5-10hp Motor Mount, 47S2633GNN
7.5-10hp Motor Mount, 47S2633GNN
SKU: 47S2633GNN
ClimateMaster
SKU: 47S2633GNN
$111.43 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coax Coil, 62B0086N02
Coax Coil, 62B0086N02
SKU: 62B0086N02
ClimateMaster
SKU: 62B0086N02
$3,971.14 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of High Pressure Switch, 13B0015N03
High Pressure Switch, 13B0015N03
SKU: 13B0015N03
ClimateMaster
SKU: 13B0015N03
$28.35 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Evaporator Coil, 61B0181N01
Evaporator Coil, 61B0181N01
SKU: 61B0181N01
ClimateMaster
SKU: 61B0181N01
$1,247.77 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Alum Air Coil Kit, S61B0404N21
Alum Air Coil Kit, S61B0404N21
SKU: S61B0404N21
ClimateMaster
SKU: S61B0404N21
$3,694.46 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0006N04S
Compressor, 34B0006N04S
SKU: 34B0006N04S
ClimateMaster
SKU: 34B0006N04S
$2,262.89 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Coil, 61S0124N55
Coil, 61S0124N55
SKU: 61S0124N55
ClimateMaster
SKU: 61S0124N55
$3,466.97 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 208V 1-Phase Compressor, 34B0216N05
$4,853.03 each
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of Cabinet, 79S0042N08
Cabinet, 79S0042N08
SKU: 79S0042N08
ClimateMaster
SKU: 79S0042N08
$531.65 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Housing, S70S0090N04
Blower Housing, S70S0090N04
SKU: S70S0090N04
ClimateMaster
SKU: S70S0090N04
$394.56 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0097N01
Compressor, 34B0097N01
SKU: 34B0097N01
ClimateMaster
SKU: 34B0097N01
$980.06 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Blower Wheel, 73B0006N01
Blower Wheel, 73B0006N01
SKU: 73B0006N01
ClimateMaster
SKU: 73B0006N01
$435.91 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Inverter Service Kit For 0930, S17B0052N01
$2,589.02 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Front Blower Panel, 41F0405GFN
Front Blower Panel, 41F0405GFN
SKU: 41F0405GFN
ClimateMaster
SKU: 41F0405GFN
$86.45 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Programmed Motor, 14S0017N18
Programmed Motor, 14S0017N18
SKU: 14S0017N18
ClimateMaster
SKU: 14S0017N18
$1,186.76 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0061N01
Compressor, 34B0061N01
SKU: 34B0061N01
ClimateMaster
SKU: 34B0061N01
$1,017.50 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 2" Fpt X Brass Thread, AFC8T
$333.98 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Motor, S14S0019N25
Blower Motor, S14S0019N25
SKU: S14S0019N25
ClimateMaster
SKU: S14S0019N25
$1,281.43 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.