Shop Resideo Sale
Filter menu expanded

Filters

1,028 items
Reset

SORT

Product Availability
–

Show In Stock Only (123)

Price Range
–

$1 to $5 (2)
$5 to $10 (15)
$10 to $15 (10)
$15 to $20 (7)
$20 to $25 (18)
$25 to $30 (15)
$30 to $35 (12)
$35 to $40 (14)
$40 to $45 (23)
$45 to $50 (16)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1028 items
Grid
List
Compare
Product Image of 2" X 2' Hose Kit, AHK2002
2" X 2' Hose Kit, AHK2002
SKU: AHK2002
ClimateMaster
SKU: AHK2002
$583.71 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 2" Hose Kit, AHK8E
2" Hose Kit, AHK8E
SKU: AHK8E
ClimateMaster
SKU: AHK8E
$1,349.91 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Electric Heater 15kw 240v, AGL15AAG
$768.01 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 1" Hose Kit 3'l Ss, AHK1003
$239.17 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 1 1/2" X 2' Hose Kit, AHK1502
$479.58 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 1" Mpt Brass Thread - Set Of 2, AFC4T
$207.41 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 1 1/4" Brass Barb Insert-set 2, AFC6I
$208.58 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 2" Fpt X Brass Thread, AFC8T
$333.98 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 208/230/1 Duct Heater, AH15GL
$895.58 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Hose Kit, AHS0752
Hose Kit, AHS0752
SKU: AHS0752
ClimateMaster
SKU: AHS0752
$288.82 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Hose Kit, AHB0752-0650
Hose Kit, AHB0752-0650
SKU: AHB0752-0650
ClimateMaster
SKU: AHB0752-0650
$552.08 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Hose Kit 1/2 X 2' 6.00gpm, AHC0502-0600
Hose Kit 1/2 X 2' 6.00gpm, AHC0502-0600
SKU: AHC0502-0600
ClimateMaster
SKU: AHC0502-0600
$260.76 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 3/4" Ball Valve w/ memory Stop, ABV075MP
$89.95 each
In Stock
Get 5 by Tue, Nov 17
In Stock
Get 5 by Tue, Nov 17
Compare
Product Image of Electronic Filter 28x30x2, AAC28302CMA
$1,540.52 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Horizontal Unit Hanger Kit, AB6413
$38.91 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Replacement Motor Taco Pump, ACP0013-MA2
$224.17 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 32x30x2 Electronic Filter, AAC32302CMA
$1,495.54 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Chassis, 81709G1PSSLSA
Chassis, 81709G1PSSLSA
SKU: 81709G1PSSLSA
ClimateMaster
SKU: 81709G1PSSLSA
$3,298.16 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of 265v Hi Rise Replacement Chasis, 81712E1SSSHSA
$3,907.53 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 15kw 460v Duct Heater, AH15FM
$1,020.22 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 15kw Electric Heater, AH15HM
$1,227.25 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Hose Kit, AHB0752-0700
Hose Kit, AHB0752-0700
SKU: AHB0752-0700
ClimateMaster
SKU: AHB0752-0700
$323.12 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 20kw Duct Heater, AGL20AAG
20kw Duct Heater, AGL20AAG
SKU: AGL20AAG
ClimateMaster
SKU: AGL20AAG
$859.01 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 8gpm Flow Regulator Valve, AFRV8
$181.66 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 1" Cam Lever For Flush Connect, AFC4C
$71.81 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Flush Cam Adapter, AFC7C
$340.99 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Flow Controller Single Pump, AFCG1C1
$1,520.21 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Flow Controller Dual Pump, AFCG2B2
$2,640.04 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Flow Controller Dual Pump, AFCG2C2
$2,061.53 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Replacement Cartridge Taco Pump, ACP0013-C3
$177.85 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Pressure Gauge, APG100
Pressure Gauge, APG100
SKU: APG100
ClimateMaster
SKU: APG100
$88.20 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Blower Assembly w/ wheel, 73B0004N02
$546.43 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Blower Housing, 73S0004N01
Blower Housing, 73S0004N01
SKU: 73S0004N01
ClimateMaster
SKU: 73S0004N01
$90.56 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Label Installer Instruction, 95B0005N02
$6.80 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of ECM Motor Upgrade Kit, EUKGS048
$1,635.21 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Resid Service Parts Kit, ASPK3
$17,631.28 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Compressor, C68832738S
Compressor, C68832738S
SKU: C68832738S
ClimateMaster
SKU: C68832738S
$1,216.74 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of Reversing Valve, C33B0008N01
Reversing Valve, C33B0008N01
SKU: C33B0008N01
ClimateMaster
SKU: C33B0008N01
$733.84 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Air Coil, CLM61S0066N55
Air Coil, CLM61S0066N55
SKU: CLM61S0066N55
ClimateMaster
SKU: CLM61S0066N55
$935.84 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of R22 Upgrade Kit, EUKGS070
R22 Upgrade Kit, EUKGS070
SKU: EUKGS070
ClimateMaster
SKU: EUKGS070
$1,230.33 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 21" Cased Air Coil, TAC049BM21S
21" Cased Air Coil, TAC049BM21S
SKU: TAC049BM21S
ClimateMaster
SKU: TAC049BM21S
$1,864.84 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of 21" Cased Air Coil, TAC038BM21S
21" Cased Air Coil, TAC038BM21S
SKU: TAC038BM21S
ClimateMaster
SKU: TAC038BM21S
$1,886.58 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of Air Coil Kit, S61B0406N21
Air Coil Kit, S61B0406N21
SKU: S61B0406N21
ClimateMaster
SKU: S61B0406N21
$2,525.34 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of Coax Coil, S62B0013N13
Coax Coil, S62B0013N13
SKU: S62B0013N13
ClimateMaster
SKU: S62B0013N13
$3,836.05 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of Hx Assembly Hot Water (fld Kit) Qe, S62S0209N12
$2,848.22 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Motor Mount Kit, S68257201
Motor Mount Kit, S68257201
SKU: S68257201
ClimateMaster
SKU: S68257201
$143.34 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Blower Motor, S14S0008N04
Blower Motor, S14S0008N04
SKU: S14S0008N04
ClimateMaster
SKU: S14S0008N04
$284.15 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Icm Control Assembly, S14S0016N22
Icm Control Assembly, S14S0016N22
SKU: S14S0016N22
ClimateMaster
SKU: S14S0016N22
$612.98 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.