Apply to be a TradeMaster!
Filter menu expanded

Filters

1,039 items
Reset

SORT

Product Availability

Show In Stock Only (113)

Price Range

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1039 items
Grid
List
Compare
Product Image of 1-1/4 Depth Gauge, HDC6P
$511.49 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Gasket, 29B0074N01
Gasket, 29B0074N01
SKU: 29B0074N01
ClimateMaster
SKU: 29B0074N01
$9.92 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Pmp Taco L1130-r6ji2-fha2 277v, 24B0034N02
$674.96 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Coax Heat Exchanger, 62C0091N01
Coax Heat Exchanger, 62C0091N01
SKU: 62C0091N01
ClimateMaster
SKU: 62C0091N01
$709.25 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Programmed ECM Converter Box, P14S0016N01
$350.66 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 28v Green Led Indicator Light, 19B0003N03
$53.88 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Wheel, 73B0006N01
Blower Wheel, 73B0006N01
SKU: 73B0006N01
ClimateMaster
SKU: 73B0006N01
$435.91 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Water Source Heat Pump Thermal Expansion Valve, 33B0005N05
$316.37 each
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Compare
Product Image of Blower Housing, 47S2109N01
Blower Housing, 47S2109N01
SKU: 47S2109N01
ClimateMaster
SKU: 47S2109N01
$46.50 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Receiver / Muffler, 36B0006N03
Receiver / Muffler, 36B0006N03
SKU: 36B0006N03
ClimateMaster
SKU: 36B0006N03
$31.19 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 10x15 2r Evap Coil, 61B0098N01
10x15 2r Evap Coil, 61B0098N01
SKU: 61B0098N01
ClimateMaster
SKU: 61B0098N01
$430.40 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 265v1ph 265v Zp16 Compressor, 34B0097N02
$1,098.06 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Fuser Holder Type Chcc2d1 600v, 16B0018N01
$171.39 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Water Coil, S62S0013N21
Water Coil, S62S0013N21
SKU: S62S0013N21
ClimateMaster
SKU: S62S0013N21
$2,912.56 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Control Box Cover Panel, 45F1785GNN
$45.15 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 15kw Electric Heater, AH15HM
$1,227.25 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Eev Stator E2v 0.3, 33B0040N01
Eev Stator E2v 0.3, 33B0040N01
SKU: 33B0040N01
ClimateMaster
SKU: 33B0040N01
$168.49 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Ea Motor 1/5hp, 3 speed Kit, S14P0002N01
$596.13 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 277v1 Ph 1/5 Hp 1075 Rpm Motor, 70021453
$539.44 each
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Compare
Product Image of 1 1/4" X 2' Hot Kit Assembly, AHA1252
$590.96 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Eec Assembly, S33S0197N02
Eec Assembly, S33S0197N02
SKU: S33S0197N02
ClimateMaster
SKU: S33S0197N02
$542.32 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 34B0133N03
Compressor, 34B0133N03
SKU: 34B0133N03
ClimateMaster
SKU: 34B0133N03
$1,476.16 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Compressor Spring, 56B0003N01
Compressor Spring, 56B0003N01
SKU: 56B0003N01
ClimateMaster
SKU: 56B0003N01
$7.02 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Cabinet Kit, 79S0042N25
Cabinet Kit, 79S0042N25
SKU: 79S0042N25
ClimateMaster
SKU: 79S0042N25
$996.00 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Reversing Vlave, 33B0056N01
Reversing Vlave, 33B0056N01
SKU: 33B0056N01
ClimateMaster
SKU: 33B0056N01
$213.50 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of R-410a 60hz 3ph 200/230v Comp, 34B0171N03
$1,314.38 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Evap Coil 20 X 18, 61S0150N55
Evap Coil 20 X 18, 61S0150N55
SKU: 61S0150N55
ClimateMaster
SKU: 61S0150N55
$1,318.81 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of ECM Motor Assembly w/ controller, S14S0019N30
$1,070.27 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Power Harness Ct Cabinet, 11B0100N32
$51.48 each
In Stock
Get 2 by Thu, Aug 20
In Stock
Get 2 by Thu, Aug 20
Compare
Product Image of Blower Motor, S14S0019N25
Blower Motor, S14S0019N25
SKU: S14S0019N25
ClimateMaster
SKU: S14S0019N25
$1,281.43 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 34B0025N03
Compressor, 34B0025N03
SKU: 34B0025N03
ClimateMaster
SKU: 34B0025N03
$1,654.07 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Outdoor Sensor, AST008
Outdoor Sensor, AST008
SKU: AST008
ClimateMaster
SKU: AST008
$47.04 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Valve Core, 39B0002N02
Valve Core, 39B0002N02
SKU: 39B0002N02
ClimateMaster
SKU: 39B0002N02
$8.51 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Heat Pump Chassis Replacement, TRM18G1SSCSB
$4,085.45 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 208v 1ph 60hz Compressor, 34B0145N01
$1,772.75 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Taco Replacement Pump Motor, ACP0013-MA3
$218.78 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of ECM Blower Motor, 14B0032N02
ECM Blower Motor, 14B0032N02
SKU: 14B0032N02
ClimateMaster
SKU: 14B0032N02
$1,064.98 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Blower Motor, S14S0008N04
Blower Motor, S14S0008N04
SKU: S14S0008N04
ClimateMaster
SKU: S14S0008N04
$284.15 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of E-coated Evap Coil 18x20, 61S0112N55
$1,759.19 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Rail Roof Long Tre096-240, 47F1342GNN
$52.43 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Evaporator Coil, 61B0161N70
Evaporator Coil, 61B0161N70
SKU: 61B0161N70
ClimateMaster
SKU: 61B0161N70
$3,177.60 each
In Stock
Get 1 by Wed, Aug 19 - Fri, Aug 21
In Stock
Get 1 by Wed, Aug 19 - Fri, Aug 21
Compare
Product Image of Evap Air Coil 18x30, 61B0174N70
Evap Air Coil 18x30, 61B0174N70
SKU: 61B0174N70
ClimateMaster
SKU: 61B0174N70
$1,331.76 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Compressor, 34B0068N02
Compressor, 34B0068N02
SKU: 34B0068N02
ClimateMaster
SKU: 34B0068N02
$998.15 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Flow Switch, 13B0053N01
Flow Switch, 13B0053N01
SKU: 13B0053N01
ClimateMaster
SKU: 13B0053N01
$357.28 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Cabinet Kit, 79S0040N05
Cabinet Kit, 79S0040N05
SKU: 79S0040N05
ClimateMaster
SKU: 79S0040N05
$624.05 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Evaporator Coil, 61B0180N01
Evaporator Coil, 61B0180N01
SKU: 61B0180N01
ClimateMaster
SKU: 61B0180N01
$922.02 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Blower Assembly, S70S0006N04
Blower Assembly, S70S0006N04
SKU: S70S0006N04
ClimateMaster
SKU: S70S0006N04
$959.16 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 34B0026N03
Compressor, 34B0026N03
SKU: 34B0026N03
ClimateMaster
SKU: 34B0026N03
$1,061.27 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.