Apply to be a TradeMaster!
Filter menu expanded

Filters

1,039 items
Reset

SORT

Product Availability

Show In Stock Only (113)

Price Range

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1039 items
Grid
List
Compare
Product Image of ECM Blower Motor, S14S0044N27
ECM Blower Motor, S14S0044N27
SKU: S14S0044N27
ClimateMaster
SKU: S14S0044N27
$862.31 each
In Stock
Get 1 by Thu, Aug 20
In Stock
Get 1 by Thu, Aug 20
Compare
Product Image of Side Panel Qev093, 41F0901GBB
Side Panel Qev093, 41F0901GBB
SKU: 41F0901GBB
ClimateMaster
SKU: 41F0901GBB
$243.89 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Resid Service Parts Kit, ASPK1
$4,855.87 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 34B0131N02
Compressor, 34B0131N02
SKU: 34B0131N02
ClimateMaster
SKU: 34B0131N02
$1,114.54 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Wire Harness, 11B0007N03
Wire Harness, 11B0007N03
SKU: 11B0007N03
ClimateMaster
SKU: 11B0007N03
$77.95 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Harness ECM Motor, S11S0001N01
Harness ECM Motor, S11S0001N01
SKU: S11S0001N01
ClimateMaster
SKU: S11S0001N01
$92.11 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 34B0048N02
Compressor, 34B0048N02
SKU: 34B0048N02
ClimateMaster
SKU: 34B0048N02
$770.63 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Filter Retainer, 46F0845GNB
Filter Retainer, 46F0845GNB
SKU: 46F0845GNB
ClimateMaster
SKU: 46F0845GNB
$26.18 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Pressure Transducer, 17B0038N02
Pressure Transducer, 17B0038N02
SKU: 17B0038N02
ClimateMaster
SKU: 17B0038N02
$180.30 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Chassis, TRM24G1KMCSA
Chassis, TRM24G1KMCSA
SKU: TRM24G1KMCSA
ClimateMaster
SKU: TRM24G1KMCSA
$5,219.55 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of 1"fpt X 5/8" Swt, 90B0002N01
1"fpt X 5/8" Swt, 90B0002N01
SKU: 90B0002N01
ClimateMaster
SKU: 90B0002N01
$39.71 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 115v 1ph Compressor, 34B0111N04
115v 1ph Compressor, 34B0111N04
SKU: 34B0111N04
ClimateMaster
SKU: 34B0111N04
$667.36 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 265v Chassis, 81712E1SFSLSA
265v Chassis, 81712E1SFSLSA
SKU: 81712E1SFSLSA
ClimateMaster
SKU: 81712E1SFSLSA
$3,737.63 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 34B0146N03
Compressor, 34B0146N03
SKU: 34B0146N03
ClimateMaster
SKU: 34B0146N03
$2,138.38 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Motorized Valve 1 1/2" w/ end, 23B0041N01
$1,162.19 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of ACNTRL01 Ctrl Conv Cmc-cxm, ACNTRL01
$486.48 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Ss Door Tev0644, 41F0467SBN
Ss Door Tev0644, 41F0467SBN
SKU: 41F0467SBN
ClimateMaster
SKU: 41F0467SBN
$248.67 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 24"x28"x2" Pleated Filter, 76B0005N14
$69.75 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 1" Hose Kit 3'l Ss, AHK1003
$239.17 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Gas Bypass Valve, 33B0046N02
Gas Bypass Valve, 33B0046N02
SKU: 33B0046N02
ClimateMaster
SKU: 33B0046N02
$563.33 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 34N0098N02
Compressor, 34N0098N02
SKU: 34N0098N02
ClimateMaster
SKU: 34N0098N02
$1,533.76 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of ECM Blower Motor, S14S0044N07
ECM Blower Motor, S14S0044N07
SKU: S14S0044N07
ClimateMaster
SKU: S14S0044N07
$1,059.09 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Control Box, S10S0171N11
Control Box, S10S0171N11
SKU: S10S0171N11
ClimateMaster
SKU: S10S0171N11
$914.91 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Contactor, 13B0002N03
Contactor, 13B0002N03
SKU: 13B0002N03
ClimateMaster
SKU: 13B0002N03
$31.19 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of ECM Blower Motor, 14B0036N14
ECM Blower Motor, 14B0036N14
SKU: 14B0036N14
ClimateMaster
SKU: 14B0036N14
$454.66 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Compressor, 68832748S
Compressor, 68832748S
SKU: 68832748S
ClimateMaster
SKU: 68832748S
$2,705.90 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Drain Pan, 49B0012N03
Drain Pan, 49B0012N03
SKU: 49B0012N03
ClimateMaster
SKU: 49B0012N03
$63.98 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Actuator Valve, 23B0012N05
Actuator Valve, 23B0012N05
SKU: 23B0012N05
ClimateMaster
SKU: 23B0012N05
$115.65 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Expansion Valve, 33B0001N02
Expansion Valve, 33B0001N02
SKU: 33B0001N02
ClimateMaster
SKU: 33B0001N02
$167.80 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Evaporator Coil, 61B0006N70
Evaporator Coil, 61B0006N70
SKU: 61B0006N70
ClimateMaster
SKU: 61B0006N70
$1,561.14 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Low Temp Harness, 11B0036N01
Low Temp Harness, 11B0036N01
SKU: 11B0036N01
ClimateMaster
SKU: 11B0036N01
$99.23 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Insulation Coax Cover A, 62I0015N11
$62.34 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 1 1/2 Gasket, 29B0018N05
1 1/2 Gasket, 29B0018N05
SKU: 29B0018N05
ClimateMaster
SKU: 29B0018N05
$7.63 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of K060 Copper Coax, 62C0046N01
K060 Copper Coax, 62C0046N01
SKU: 62C0046N01
ClimateMaster
SKU: 62C0046N01
$1,345.22 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Coax Coil, 62B0103N01
Coax Coil, 62B0103N01
SKU: 62B0103N01
ClimateMaster
SKU: 62B0103N01
$3,393.48 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Control Board, 14B0036N21
Control Board, 14B0036N21
SKU: 14B0036N21
ClimateMaster
SKU: 14B0036N21
$589.03 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Motor Bracket, 47S1510GNN
Motor Bracket, 47S1510GNN
SKU: 47S1510GNN
ClimateMaster
SKU: 47S1510GNN
$128.98 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Air Coil, 61B0081N01
Air Coil, 61B0081N01
SKU: 61B0081N01
ClimateMaster
SKU: 61B0081N01
$944.52 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of Belt Linkage, 696-006
Belt Linkage, 696-006
SKU: 696-006
ClimateMaster
SKU: 696-006
$426.55 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Copper Insltd Coax Water Coil, S62S0010N21
$1,731.55 each
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Backorder
Get it by Thu, Sep 17 - Mon, Oct 19
Compare
Product Image of 15kw Axl, AH15GM
15kw Axl, AH15GM
SKU: AH15GM
ClimateMaster
SKU: AH15GM
$895.61 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of TXV Valve, 33B0027N01
TXV Valve, 33B0027N01
SKU: 33B0027N01
ClimateMaster
SKU: 33B0027N01
$169.81 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Therm Clip, 17B0032N01
Therm Clip, 17B0032N01
SKU: 17B0032N01
ClimateMaster
SKU: 17B0032N01
$7.88 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 1" X 2" Hose Kit, AHA1002
1" X 2" Hose Kit, AHA1002
SKU: AHA1002
ClimateMaster
SKU: AHA1002
$312.54 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Inverter Service Kit For 0930, S17B0052N01
$2,589.02 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Hose Kit, AHB0752-0900
Hose Kit, AHB0752-0900
SKU: AHB0752-0900
ClimateMaster
SKU: AHB0752-0900
$379.36 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 24v On/off Actuator, 23B0105N01
24v On/off Actuator, 23B0105N01
SKU: 23B0105N01
ClimateMaster
SKU: 23B0105N01
$317.78 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Cabinet, 79S0042N08
Cabinet, 79S0042N08
SKU: 79S0042N08
ClimateMaster
SKU: 79S0042N08
$531.65 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.