Shop Resideo Sale
Filter menu expanded

Filters

1,028 items
Reset

SORT

Product Availability
–

Show In Stock Only (123)

Price Range
–

$1 to $5 (2)
$5 to $10 (15)
$10 to $15 (10)
$15 to $20 (7)
$20 to $25 (18)
$25 to $30 (15)
$30 to $35 (12)
$35 to $40 (14)
$40 to $45 (23)
$45 to $50 (16)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1028 items
Grid
List
Compare
Product Image of Control Board, 17B0040N01
Control Board, 17B0040N01
SKU: 17B0040N01
ClimateMaster
SKU: 17B0040N01
$330.10 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Control Conversion Kit Ccm-cxm, ACNTRL08
$496.32 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Muffler, 36B0006N01
Muffler, 36B0006N01
SKU: 36B0006N01
ClimateMaster
SKU: 36B0006N01
$56.51 each
In Stock
Get 2 by Wed, Nov 18
In Stock
Get 2 by Wed, Nov 18
Compare
Product Image of 1 Fpt Solenoid Valve, AVSP5
$159.84 each
In Stock
Get 1 by Wed, Nov 18
In Stock
Get 1 by Wed, Nov 18
Compare
Product Image of 30x36x2 Merv11 Pleated Filter, P1S2293356
$86.84 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Slaving Module, APSM
$178.09 each
In Stock
Get 2 by Wed, Nov 18
In Stock
Get 2 by Wed, Nov 18
Compare
Product Image of Wire Assembly Yellow Condensate, 11B0009N03
$22.75 each
In Stock
Get 4 by Wed, Nov 18
In Stock
Get 4 by Wed, Nov 18
Compare
Product Image of 265v1ph R410a Compressor, 34B0108N02
$849.08 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of TXV Valve, 33B0020N02
TXV Valve, 33B0020N02
SKU: 33B0020N02
ClimateMaster
SKU: 33B0020N02
$208.74 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of O-ring Un125, 29B0016N02
O-ring Un125, 29B0016N02
SKU: 29B0016N02
ClimateMaster
SKU: 29B0016N02
$7.28 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 230v Dual Shaft Blower Motor, 14B0024N01
$358.80 each
In Stock
Get 8 by Wed, Nov 18
In Stock
Get 8 by Wed, Nov 18
Compare
Product Image of Fuse Cxm Ce, 16B0028N02
Fuse Cxm Ce, 16B0028N02
SKU: 16B0028N02
ClimateMaster
SKU: 16B0028N02
$10.50 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of ECM Motor Harness, 11B0012N05
ECM Motor Harness, 11B0012N05
SKU: 11B0012N05
ClimateMaster
SKU: 11B0012N05
$49.39 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Blue Thermistor, 17B0030N04
Blue Thermistor, 17B0030N04
SKU: 17B0030N04
ClimateMaster
SKU: 17B0030N04
$29.44 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 7/8"s Union x 3/4"fpt Ball Valve, 23B0016N02
$95.52 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Ecm Blower Motor W/ Controller, S14S0017N17
$1,079.75 each
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Compare
Product Image of 70mfd 370v Capacitor, 15B0013N19
70mfd 370v Capacitor, 15B0013N19
SKU: 15B0013N19
ClimateMaster
SKU: 15B0013N19
$48.73 each
In Stock
Get 1 by Wed, Nov 18
In Stock
Get 1 by Wed, Nov 18
Compare
Product Image of 208/230v3 speed 1/20hp 1155rpm Cw, 14B0021N04
$331.12 each
In Stock
Get 2 by Wed, Nov 18
In Stock
Get 2 by Wed, Nov 18
Compare
Product Image of Control Board, 17B0003N04
Control Board, 17B0003N04
SKU: 17B0003N04
ClimateMaster
SKU: 17B0003N04
$203.10 each
In Stock
Get 1 by Tue, Nov 17
In Stock
Get 1 by Tue, Nov 17
Compare
Product Image of Evaporator Coil, 61B0243N70
Evaporator Coil, 61B0243N70
SKU: 61B0243N70
ClimateMaster
SKU: 61B0243N70
$1,449.51 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of Hose Kit, AHH05024SC
Hose Kit, AHH05024SC
SKU: AHH05024SC
ClimateMaster
SKU: AHH05024SC
$77.22 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Compressor Plug, 15B0008N03
Compressor Plug, 15B0008N03
SKU: 15B0008N03
ClimateMaster
SKU: 15B0008N03
$50.85 each
In Stock
Get 1 by Wed, Nov 18
In Stock
Get 1 by Wed, Nov 18
Compare
Product Image of Upmxl Pump, S24B0023N02
Upmxl Pump, S24B0023N02
SKU: S24B0023N02
ClimateMaster
SKU: S24B0023N02
$2,367.61 each
In Stock
Get 1 by Wed, Nov 18
In Stock
Get 1 by Wed, Nov 18
Compare
Product Image of 10kw Heater Element, 18B0006N01
10kw Heater Element, 18B0006N01
SKU: 18B0006N01
ClimateMaster
SKU: 18B0006N01
$141.97 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of TXV, 33B0058N01
TXV, 33B0058N01
SKU: 33B0058N01
ClimateMaster
SKU: 33B0058N01
$218.47 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 1/4hp 3 Speed Motor, 14B0014N04
1/4hp 3 Speed Motor, 14B0014N04
SKU: 14B0014N04
ClimateMaster
SKU: 14B0014N04
$535.39 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Evap. Coil, 61B0246N70
Evap. Coil, 61B0246N70
SKU: 61B0246N70
ClimateMaster
SKU: 61B0246N70
$1,971.38 each
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Backorder
Get it by Thu, Dec 17 - Fri, Jan 22
Compare
Product Image of Hose Kit, AHC0752-0600
Hose Kit, AHC0752-0600
SKU: AHC0752-0600
ClimateMaster
SKU: AHC0752-0600
$506.23 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Thermistor, EBG61286235
Thermistor, EBG61286235
SKU: EBG61286235
ClimateMaster
SKU: EBG61286235
$25.51 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Mpc Field Upgrade Kit, ACNTRL06
$902.48 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Outdoor Sensor, AST008
Outdoor Sensor, AST008
SKU: AST008
ClimateMaster
SKU: AST008
$48.77 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Motor 1/3 HP 3 Speed, 14B0003N04
Motor 1/3 HP 3 Speed, 14B0003N04
SKU: 14B0003N04
ClimateMaster
SKU: 14B0003N04
$228.82 each
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Compare
Product Image of 1/2-1/3hp 460/380-420v 48y 3sp, 14S0008N04
$541.96 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Limit Switch, 13B0005N01
Limit Switch, 13B0005N01
SKU: 13B0005N01
ClimateMaster
SKU: 13B0005N01
$49.89 each
In Stock
Get 1 by Wed, Nov 18
In Stock
Get 1 by Wed, Nov 18
Compare
Product Image of Black Thermistor, 17B0031N04
Black Thermistor, 17B0031N04
SKU: 17B0031N04
ClimateMaster
SKU: 17B0031N04
$50.81 each
In Stock
Get 1 by Wed, Nov 18
In Stock
Get 1 by Wed, Nov 18
Compare
Product Image of Coax Coil w/  Bracket, 62C0009N01
Coax Coil w/ Bracket, 62C0009N01
SKU: 62C0009N01
ClimateMaster
SKU: 62C0009N01
$1,399.55 each
In Stock
Get 1 by Mon, Nov 23 - Fri, Nov 27
In Stock
Get 1 by Mon, Nov 23 - Fri, Nov 27
Compare
Product Image of Molded Compressor Plug, 15B0008N07
Molded Compressor Plug, 15B0008N07
SKU: 15B0008N07
ClimateMaster
SKU: 15B0008N07
$118.20 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Capacitor, 15B0013N34
Capacitor, 15B0013N34
SKU: 15B0013N34
ClimateMaster
SKU: 15B0013N34
$37.40 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Low Temp Switch, 13B0027N03
Low Temp Switch, 13B0027N03
SKU: 13B0027N03
ClimateMaster
SKU: 13B0027N03
$123.82 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Wiring Harness, 11B0011N02
Wiring Harness, 11B0011N02
SKU: 11B0011N02
ClimateMaster
SKU: 11B0011N02
$41.92 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 29-1/4" x 31-7/8" x 2" MERV 11 Filter, 21211C02292531875
$103.79 each
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Compare
Product Image of Front Bottom Panel, 41F0496GFB
Front Bottom Panel, 41F0496GFB
SKU: 41F0496GFB
ClimateMaster
SKU: 41F0496GFB
$107.73 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Blower Bearing, 68540503
Blower Bearing, 68540503
SKU: 68540503
ClimateMaster
SKU: 68540503
$173.70 each
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Compare
Product Image of Trilogy Zoning Control, AZC06CAR
$1,137.90 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Thermostat, ATP32U03C
Thermostat, ATP32U03C
SKU: ATP32U03C
ClimateMaster
SKU: ATP32U03C
$371.49 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of 3ht/2cl Programmable Thermostat, ATP32U06
$584.61 each
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Out of Stock
Get it by Wed, Dec 2 - Wed, Dec 9
Compare
Product Image of Stat, AVB32V03R
Stat, AVB32V03R
SKU: AVB32V03R
ClimateMaster
SKU: AVB32V03R
$580.79 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Compare
Product Image of Software Moc Field Appldr Kit, AAPPLDRKIT
$811.58 each
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Backorder
Get it by Wed, Dec 16 - Tue, Jan 19
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.