Product Image of Air Coil 32x25 3r Tin Plated, 61B0160N70
$2,604.60 each
In Stock
Get 2 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 2 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of Reversing Valve W/ O Coil, 69172601
$132.46 each
In Stock
Get 2 by Tue, Oct 6
In Stock
Get 2 by Tue, Oct 6
Compare
Product Image of Capacitor, 15B0013N20
Capacitor, 15B0013N20
SKU: 15B0013N20
ClimateMaster
SKU: 15B0013N20
$80.32 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of 230/1/60 Compressor, 34B0067N01
230/1/60 Compressor, 34B0067N01
SKU: 34B0067N01
ClimateMaster
SKU: 34B0067N01
$895.72 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Coil, 61B0245N70
Air Coil, 61B0245N70
SKU: 61B0245N70
ClimateMaster
SKU: 61B0245N70
$1,624.59 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Yellow Thermistor, 17B0030N05
Yellow Thermistor, 17B0030N05
SKU: 17B0030N05
ClimateMaster
SKU: 17B0030N05
$41.10 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Water Pressure Switch, 39B0017N03
Water Pressure Switch, 39B0017N03
SKU: 39B0017N03
ClimateMaster
SKU: 39B0017N03
$34.01 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Transformer, 15B0021N05
Transformer, 15B0021N05
SKU: 15B0021N05
ClimateMaster
SKU: 15B0021N05
$62.40 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Capacitor, 15B0013N34
Capacitor, 15B0013N34
SKU: 15B0013N34
ClimateMaster
SKU: 15B0013N34
$35.45 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of ECM Motor Assembly With Controller, S14S0016N06
$980.11 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Front Bottom Panel, 41F0496GFB
Front Bottom Panel, 41F0496GFB
SKU: 41F0496GFB
ClimateMaster
SKU: 41F0496GFB
$102.05 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 230v1ph 54,000btu R-410a Compressor, 34B0133N01
$1,282.02 each
In Stock
Get 4 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 4 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of Low Temp Switch, 13B0027N03
Low Temp Switch, 13B0027N03
SKU: 13B0027N03
ClimateMaster
SKU: 13B0027N03
$126.12 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Geothermal Hose Kit, AHK5EC
Geothermal Hose Kit, AHK5EC
SKU: AHK5EC
ClimateMaster
SKU: AHK5EC
$448.81 each
In Stock
Get 1 by Mon, Oct 5
In Stock
Get 1 by Mon, Oct 5
Compare
Product Image of 30mfd 370v Round Run Capacitor, 15B0013N12
$19.84 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Hose Kit, AHH05024SC
Hose Kit, AHH05024SC
SKU: AHH05024SC
ClimateMaster
SKU: AHH05024SC
$77.22 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Soft Start Kit, 13B0045N01
Soft Start Kit, 13B0045N01
SKU: 13B0045N01
ClimateMaster
SKU: 13B0045N01
$679.51 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Dxm2 Upgrade Kit, S17S0002N25U2
Dxm2 Upgrade Kit, S17S0002N25U2
SKU: S17S0002N25U2
ClimateMaster
SKU: S17S0002N25U2
$969.50 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of 1/8 HP 240/277V Motor, S14S0039N03
1/8 HP 240/277V Motor, S14S0039N03
SKU: S14S0039N03
ClimateMaster
SKU: S14S0039N03
$851.94 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Evaporator Coil, 61B0501N01
Evaporator Coil, 61B0501N01
SKU: 61B0501N01
ClimateMaster
SKU: 61B0501N01
$1,596.74 each
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of 208/230v3 speed 1/20hp 1155rpm Cw, 14B0021N04
$313.70 each
In Stock
Get 2 by Tue, Oct 6
In Stock
Get 2 by Tue, Oct 6
Compare
Product Image of Field Diagnostic Service Tool, ASVCTOOL01
$604.09 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 265v R22 1hp Compressor, 34B0070N01
$832.59 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Capacitor, 15B0013N33
Capacitor, 15B0013N33
SKU: 15B0013N33
ClimateMaster
SKU: 15B0013N33
$34.02 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Ecm Blower Motor W/ Controller, S14S0017N17
$1,022.90 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Capacitor, 15B0013N15
Capacitor, 15B0013N15
SKU: 15B0013N15
ClimateMaster
SKU: 15B0013N15
$42.40 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of TXV Valve, 33B0020N02
TXV Valve, 33B0020N02
SKU: 33B0020N02
ClimateMaster
SKU: 33B0020N02
$197.75 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 10kw 240v Duct Heater, AGL10CBG
$562.79 each
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Compare
Product Image of Air Coil 16x22 3r Tin Plated, 61B0238N70
$1,339.10 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 10kw Heater Element, 18B0004N01
10kw Heater Element, 18B0004N01
SKU: 18B0004N01
ClimateMaster
SKU: 18B0004N01
$151.62 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Motor & Module, S14S0017N06
Blower Motor & Module, S14S0017N06
SKU: S14S0017N06
ClimateMaster
SKU: S14S0017N06
$1,170.94 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Hot Water Coax, 63B0004N01
Hot Water Coax, 63B0004N01
SKU: 63B0004N01
ClimateMaster
SKU: 63B0004N01
$456.91 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 265v R22 Compressor, 34B0024N02
265v R22 Compressor, 34B0024N02
SKU: 34B0024N02
ClimateMaster
SKU: 34B0024N02
$976.23 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Hot Water Generator, 63B0005N05
Hot Water Generator, 63B0005N05
SKU: 63B0005N05
ClimateMaster
SKU: 63B0005N05
$648.06 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 34B0024N03
Compressor, 34B0024N03
SKU: 34B0024N03
ClimateMaster
SKU: 34B0024N03
$1,193.19 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Air Coil, CLM61S0066N55
Air Coil, CLM61S0066N55
SKU: CLM61S0066N55
ClimateMaster
SKU: CLM61S0066N55
$935.84 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 1" Cam Lever For Flush Connect, AFC4C
$69.29 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Inlet Ring, 72B0002N01
Inlet Ring, 72B0002N01
SKU: 72B0002N01
ClimateMaster
SKU: 72B0002N01
$69.43 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Water Coil, 62B0017N01
Water Coil, 62B0017N01
SKU: 62B0017N01
ClimateMaster
SKU: 62B0017N01
$602.62 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 34B0025N03
Compressor, 34B0025N03
SKU: 34B0025N03
ClimateMaster
SKU: 34B0025N03
$1,654.07 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Copper Coax Coil, 63C0003N05
Copper Coax Coil, 63C0003N05
SKU: 63C0003N05
ClimateMaster
SKU: 63C0003N05
$947.04 each
In Stock
Get 3 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 3 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of Coax Water Coil, 62C0011N01
Coax Water Coil, 62C0011N01
SKU: 62C0011N01
ClimateMaster
SKU: 62C0011N01
$864.03 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 1" Brass Barb Insert Ser Of 2, AFC4I
$182.81 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Evap Air Coil 36x36 2r, 61S0078N55
Evap Air Coil 36x36 2r, 61S0078N55
SKU: 61S0078N55
ClimateMaster
SKU: 61S0078N55
$2,043.96 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Vertical Stack, 81709G1PESCSA
Vertical Stack, 81709G1PESCSA
SKU: 81709G1PESCSA
ClimateMaster
SKU: 81709G1PESCSA
$3,872.66 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Front Bottom Door, 41F1071SFN
Front Bottom Door, 41F1071SFN
SKU: 41F1071SFN
ClimateMaster
SKU: 41F1071SFN
$127.57 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Motor Mount Arm, 75B0001N04
Motor Mount Arm, 75B0001N04
SKU: 75B0001N04
ClimateMaster
SKU: 75B0001N04
$21.74 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Stat, AVB32V03R
Stat, AVB32V03R
SKU: AVB32V03R
ClimateMaster
SKU: AVB32V03R
$563.87 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.