Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Hose Kit, AHC0502-0350
Hose Kit, AHC0502-0350
SKU: AHC0502-0350
ClimateMaster
SKU: AHC0502-0350
$243.96 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Chassis, 81709G1PSSLSA
Chassis, 81709G1PSSLSA
SKU: 81709G1PSSLSA
ClimateMaster
SKU: 81709G1PSSLSA
$3,298.16 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Front Compressor Panel, 41F1074GFS
Front Compressor Panel, 41F1074GFS
SKU: 41F1074GFS
ClimateMaster
SKU: 41F1074GFS
$85.04 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Hose Adapter, 29S0019N07
Hose Adapter, 29S0019N07
SKU: 29S0019N07
ClimateMaster
SKU: 29S0019N07
$116.25 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Evap Coil 3 Row, 61S0014N55
Evap Coil 3 Row, 61S0014N55
SKU: 61S0014N55
ClimateMaster
SKU: 61S0014N55
$1,595.76 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 4gpm Flow Regulator Valve, AFRV4
$164.06 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Evaporator Coil, 61B0161N70
Evaporator Coil, 61B0161N70
SKU: 61B0161N70
ClimateMaster
SKU: 61B0161N70
$3,177.60 each
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of Blower Panel Right-up/left-dn, 43F0368GBB
$163.46 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 20" Harness, 11B0033N03
20" Harness, 11B0033N03
SKU: 11B0033N03
ClimateMaster
SKU: 11B0033N03
$24.11 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Tsm24 Chassis Only, TSM24GSBJML6BSC
Tsm24 Chassis Only, TSM24GSBJML6BSC
SKU: TSM24GSBJML6BSC
ClimateMaster
SKU: TSM24GSBJML6BSC
$3,672.18 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Brazed Plate Heat Exchanger, 62B0022N01
$3,090.63 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 15"x15"r Fan/housing Assembly, 685369-06
$1,390.17 each
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 1 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of Ss 1" X 2' Hose Kit, AHK1002
$185.37 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Filter Rack Retainer, 46F0872GNB
Filter Rack Retainer, 46F0872GNB
SKU: 46F0872GNB
ClimateMaster
SKU: 46F0872GNB
$34.02 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 15kw 460v Duct Heater, AH15FM
$1,020.22 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Programmed ECM Motor, S14S0044N23
Programmed ECM Motor, S14S0044N23
SKU: S14S0044N23
ClimateMaster
SKU: S14S0044N23
$1,101.64 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Chassis, TRM18G1SSLSB
Chassis, TRM18G1SSLSB
SKU: TRM18G1SSLSB
ClimateMaster
SKU: TRM18G1SSLSB
$3,284.71 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 530-507
Compressor, 530-507
SKU: 530-507
ClimateMaster
SKU: 530-507
$12,681.90 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Coxial Water Coil w/ bracket, 62C0020N01
$1,391.14 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 34B0026N03
Compressor, 34B0026N03
SKU: 34B0026N03
ClimateMaster
SKU: 34B0026N03
$1,061.27 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Pressure Transducer, 17B0038N01
Pressure Transducer, 17B0038N01
SKU: 17B0038N01
ClimateMaster
SKU: 17B0038N01
$125.24 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Switch, N/o Push Button 24v, 13B0016N02
$45.36 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 2 Heat 1 Cool Programmable Stat, ATP21W02
$145.80 each
In Stock
Get 2 by Tue, Oct 6
In Stock
Get 2 by Tue, Oct 6
Compare
Product Image of Compressor Plug, 15B0008N10
Compressor Plug, 15B0008N10
SKU: 15B0008N10
ClimateMaster
SKU: 15B0008N10
$69.49 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 208/230v 1ph Compressor, 34B0047N01
$860.28 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Air Coil, 61B0214N01
Air Coil, 61B0214N01
SKU: 61B0214N01
ClimateMaster
SKU: 61B0214N01
$1,020.66 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 18" Unit Stand 018-030 Pgk 4, ACSVAMBS
$713.03 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Motor 1hp Icm 230v, S68173485
Motor 1hp Icm 230v, S68173485
SKU: S68173485
ClimateMaster
SKU: S68173485
$1,848.00 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Copper Coax K024, 62C0014N01
Copper Coax K024, 62C0014N01
SKU: 62C0014N01
ClimateMaster
SKU: 62C0014N01
$653.41 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Therm Clip, 17B0032N01
Therm Clip, 17B0032N01
SKU: 17B0032N01
ClimateMaster
SKU: 17B0032N01
$7.88 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Breaker, 16B0001N07
Breaker, 16B0001N07
SKU: 16B0001N07
ClimateMaster
SKU: 16B0001N07
$212.25 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Coil, 61B0009N70
Air Coil, 61B0009N70
SKU: 61B0009N70
ClimateMaster
SKU: 61B0009N70
$2,373.19 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 208-230v 1 Ph R410a 2-1/2 Ton Com, 34B0143N01
$3,156.55 each
Out of Stock
Get it by Mon, Oct 19 - Wed, Oct 28
Out of Stock
Get it by Mon, Oct 19 - Wed, Oct 28
Compare
Product Image of Blower Motor Assembly, S14S0008N02
Blower Motor Assembly, S14S0008N02
SKU: S14S0008N02
ClimateMaster
SKU: S14S0008N02
$859.06 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 265v R22 Compressor, 34B0018N02
265v R22 Compressor, 34B0018N02
SKU: 34B0018N02
ClimateMaster
SKU: 34B0018N02
$879.83 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Evap Coil, 61B0177N70
Evap Coil, 61B0177N70
SKU: 61B0177N70
ClimateMaster
SKU: 61B0177N70
$1,389.85 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 1 1/4" Pe Socket Fusion-set 2, AFC6F
$47.89 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 4mfd 440v Oval Run Capacitor, 15B0013N21
$18.41 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Access Panel, 41F0489GFS
Access Panel, 41F0489GFS
SKU: 41F0489GFS
ClimateMaster
SKU: 41F0489GFS
$82.22 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Diagnostic, AULTRACHK
Diagnostic, AULTRACHK
SKU: AULTRACHK
ClimateMaster
SKU: AULTRACHK
$1,083.67 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coax Coil, 62C0944802
Coax Coil, 62C0944802
SKU: 62C0944802
ClimateMaster
SKU: 62C0944802
$3,781.69 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Blk Zone Sentry Kit, 11B0050N01
Blk Zone Sentry Kit, 11B0050N01
SKU: 11B0050N01
ClimateMaster
SKU: 11B0050N01
$68.06 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Coil, 61B0028N01
Air Coil, 61B0028N01
SKU: 61B0028N01
ClimateMaster
SKU: 61B0028N01
$1,199.56 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Air Coil, 61S0151N55
Air Coil, 61S0151N55
SKU: 61S0151N55
ClimateMaster
SKU: 61S0151N55
$824.70 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Hose Kit, AHB0752-0700
Hose Kit, AHB0752-0700
SKU: AHB0752-0700
ClimateMaster
SKU: AHB0752-0700
$323.12 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0099N05
Compressor, 34B0099N05
SKU: 34B0099N05
ClimateMaster
SKU: 34B0099N05
$1,202.28 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Coated Coil, 61S0108N55
Coated Coil, 61S0108N55
SKU: 61S0108N55
ClimateMaster
SKU: 61S0108N55
$1,901.14 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Blower Assembly, S70S0001N12
Blower Assembly, S70S0001N12
SKU: S70S0001N12
ClimateMaster
SKU: S70S0001N12
$605.45 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.