Apply to be a TradeMaster!
Filter menu expanded

Filters

1,030 items
Reset

SORT

Product Availability
–

Show In Stock Only (133)

Price Range
–

$1 to $5 (2)
$5 to $10 (18)
$10 to $15 (8)
$15 to $20 (9)
$20 to $25 (18)
$25 to $30 (13)
$30 to $35 (14)
$35 to $40 (15)
$40 to $45 (16)
$45 to $50 (24)

ClimateMaster Parts - Heat Pump

Help Face
Need a little help?
1030 items
Grid
List
Compare
Product Image of Pump, 24B0010N02
Pump, 24B0010N02
SKU: 24B0010N02
ClimateMaster
SKU: 24B0010N02
$6,010.89 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Expansion Valve, 33B0002N08
Expansion Valve, 33B0002N08
SKU: 33B0002N08
ClimateMaster
SKU: 33B0002N08
$145.71 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Motor 1/8 HP 230v, 14B0026N01
Motor 1/8 HP 230v, 14B0026N01
SKU: 14B0026N01
ClimateMaster
SKU: 14B0026N01
$343.22 each
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Compare
Product Image of Blower Housing, 73S0004N01
Blower Housing, 73S0004N01
SKU: 73S0004N01
ClimateMaster
SKU: 73S0004N01
$90.56 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Blower Housing, S12331623
Blower Housing, S12331623
SKU: S12331623
ClimateMaster
SKU: S12331623
$198.43 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Control box Qe/ve G Com Hi-volt, S10S0601N01
$6,127.41 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor 460v Gsd80385vab422, 34B0147N02
$17,665.66 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Hose Kit, AHC0502-0400
Hose Kit, AHC0502-0400
SKU: AHC0502-0400
ClimateMaster
SKU: AHC0502-0400
$571.85 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor Oor Bottom Panel, 41F1075GFS
$96.41 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Drain Connect Kit, 29S0081N01
Drain Connect Kit, 29S0081N01
SKU: 29S0081N01
ClimateMaster
SKU: 29S0081N01
$39.72 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Belt, 75B0003N01
Belt, 75B0003N01
SKU: 75B0003N01
ClimateMaster
SKU: 75B0003N01
$100.61 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 265v1ph Gk Compressor, 34B0111N02
265v1ph Gk Compressor, 34B0111N02
SKU: 34B0111N02
ClimateMaster
SKU: 34B0111N02
$991.49 each
In Stock
Get 2 by Thu, Oct 8 - Tue, Oct 13
In Stock
Get 2 by Thu, Oct 8 - Tue, Oct 13
Compare
Product Image of Mpc Controller, 17S0012N46
Mpc Controller, 17S0012N46
SKU: 17S0012N46
ClimateMaster
SKU: 17S0012N46
$1,042.21 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coax Coil Cupro-nickle, 62C0009N02
Coax Coil Cupro-nickle, 62C0009N02
SKU: 62C0009N02
ClimateMaster
SKU: 62C0009N02
$1,931.51 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 20x20 3row E-coated Air Coil, 61S0016N55
$1,594.76 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 8gpm Flow Regulator Valve, AFRV8
$175.80 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Expansion Valve Bbive - 1, 68266314
$152.55 each
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Out of Stock
Get it by Fri, Oct 16 - Fri, Oct 23
Compare
Product Image of Air Evaporator Coil, 61B0163N70
Air Evaporator Coil, 61B0163N70
SKU: 61B0163N70
ClimateMaster
SKU: 61B0163N70
$1,547.19 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Top Panel, 43F0372GFB
Top Panel, 43F0372GFB
SKU: 43F0372GFB
ClimateMaster
SKU: 43F0372GFB
$156.87 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Filter Drier, Biflow, 36B0003N03
Filter Drier, Biflow, 36B0003N03
SKU: 36B0003N03
ClimateMaster
SKU: 36B0003N03
$93.67 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Low Temp Harness, 11B0036N01
Low Temp Harness, 11B0036N01
SKU: 11B0036N01
ClimateMaster
SKU: 11B0036N01
$99.23 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Up26-99f 3h 277v Pump, 24B0003N25
Up26-99f 3h 277v Pump, 24B0003N25
SKU: 24B0003N25
ClimateMaster
SKU: 24B0003N25
$663.32 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Pressure Gauge, APG100
Pressure Gauge, APG100
SKU: APG100
ClimateMaster
SKU: APG100
$88.20 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Thermistor, 17B0008N01
Thermistor, 17B0008N01
SKU: 17B0008N01
ClimateMaster
SKU: 17B0008N01
$91.47 each
In Stock
Get 1 by Tue, Oct 6
In Stock
Get 1 by Tue, Oct 6
Compare
Product Image of Horizontal Unit Hanger Kit, AB6413
$36.86 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of ECM Blower Motor, S14S0044N07
ECM Blower Motor, S14S0044N07
SKU: S14S0044N07
ClimateMaster
SKU: S14S0044N07
$1,059.09 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 208-230/460v3ph 1.5hp 1740rpm, 14B0015N18
$1,601.17 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Vertstack Heat Pump Chassis, TSM24GSBJMLSDSC
Vertstack Heat Pump Chassis, TSM24GSBJMLSDSC
SKU: TSM24GSBJMLSDSC
ClimateMaster
SKU: TSM24GSBJMLSDSC
$5,318.16 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Water condenser coil copper coax, 62C0930802
$1,362.64 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of 12kw Heat Kit, AGM12AAG
12kw Heat Kit, AGM12AAG
SKU: AGM12AAG
ClimateMaster
SKU: AGM12AAG
$723.11 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Equipment Touch Mpc Svl Tool, AEQTOUCH6
$1,564.36 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Air Coil, 61B0703N01
Air Coil, 61B0703N01
SKU: 61B0703N01
ClimateMaster
SKU: 61B0703N01
$2,620.07 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Compressor, 34B0145N03
Compressor, 34B0145N03
SKU: 34B0145N03
ClimateMaster
SKU: 34B0145N03
$2,743.88 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coil 28x14 2row Cond Coil, 61B0588N01
$1,542.36 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Air Coil, 61B0505N01
Air Coil, 61B0505N01
SKU: 61B0505N01
ClimateMaster
SKU: 61B0505N01
$1,620.89 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Evap Coil Copper,non Coated, 62B0024N01
$4,209.29 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Blower Assembly, 73B0009N01
Blower Assembly, 73B0009N01
SKU: 73B0009N01
ClimateMaster
SKU: 73B0009N01
$1,688.00 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Wall Mount Room Sensor No Dis, ASW006
$51.88 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Remote Mount Hwg Kit, AHWG1BASS
Remote Mount Hwg Kit, AHWG1BASS
SKU: AHWG1BASS
ClimateMaster
SKU: AHWG1BASS
$1,746.88 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 1" Hose Kit 3'l Ss, AHK1003
$239.17 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Filter Retainer, 46F0981GNB
Filter Retainer, 46F0981GNB
SKU: 46F0981GNB
ClimateMaster
SKU: 46F0981GNB
$48.22 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of 208/230/1 Duct Heater, AH15GL
$895.58 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Controller, 17B0012N20
Controller, 17B0012N20
SKU: 17B0012N20
ClimateMaster
SKU: 17B0012N20
$691.36 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Wiring Harness, 11B0008N02
Wiring Harness, 11B0008N02
SKU: 11B0008N02
ClimateMaster
SKU: 11B0008N02
$22.67 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Coax K061asca Sw C Bracket 8 Flut, 62B0039N01
$426.28 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Compressor, 34B0041N02S
Compressor, 34B0041N02S
SKU: 34B0041N02S
ClimateMaster
SKU: 34B0041N02S
$2,154.19 each
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Backorder
Get it by Mon, Nov 2 - Thu, Dec 3
Compare
Product Image of Reverse Valve Solenoid, 15B0005N02
Reverse Valve Solenoid, 15B0005N02
SKU: 15B0005N02
ClimateMaster
SKU: 15B0005N02
$29.77 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Compare
Product Image of Motor, S14S0044N24
Motor, S14S0044N24
SKU: S14S0044N24
ClimateMaster
SKU: S14S0044N24
$1,030.56 each
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Backorder
Get it by Fri, Oct 30 - Mon, Nov 30
Resources
FAQs, Manuals & Videos
Articles
More About ClimateMaster Parts

ClimateMaster parts support the water source and geothermal heat pump systems ClimateMaster builds for residential and commercial buildings, which use the stable underground or water-loop temperature instead of outdoor air to heat and cool. Because these systems trade an outdoor condenser for a ground loop or water loop, the compressor, coaxial heat exchanger, and reversing valve inside the indoor cabinet see more consistent operating conditions than a typical air source system, but they still wear over the equipment's service life. ClimateMaster indoor units are commonly rated for service lives well beyond twenty years, with ground loops lasting even longer, which means a shop servicing these systems is often working on equipment that has outlasted several other components in the building. Confirming the exact model and cabinet configuration before ordering matters more with geothermal equipment than with standard split systems, since parts are less commonly interchangeable across model families. Stocking the parts specific to the ClimateMaster models a service area has installed in volume avoids ordering delays on time-sensitive repairs.

Subcategories

  • Compressors: The compressor in a water source or geothermal heat pump circulates refrigerant between the coaxial heat exchanger and the indoor coil, and it typically runs under steadier load conditions than an air source compressor since ground or water loop temperatures fluctuate less than outdoor air. Confirming the exact compressor model against the unit's nameplate is important since ClimateMaster has produced multiple cabinet and capacity configurations. Compressor replacement is one of the higher cost repairs on these systems. A failed compressor often shows up alongside a high-pressure or low-pressure fault code on the unit's controls.
  • Control Boards: Control boards manage compressor operation, fan staging, and safety lockouts, and a fault here can affect multiple functions at once depending on which board and function are involved. Boards are model and revision specific, so confirming the exact unit configuration before ordering avoids a mismatch. These systems often log fault codes that point toward a specific board or sensor issue, which narrows down troubleshooting compared to a simple no-cool complaint. Power quality issues are a common contributor to board failures in commercial installations.
  • Reversing Valves: The reversing valve switches the system between heating and cooling mode by redirecting refrigerant flow, and a failure here typically shows the system stuck in one mode regardless of the thermostat call. This is a moderately involved repair that requires refrigerant recovery and recharge, so it is not a quick parts swap. A reversing valve that fails to fully shift, rather than failing outright, can sometimes be mistaken for a control or sensor issue during initial diagnosis. Confirming the valve is the actual point of failure before ordering avoids replacing a working part.
  • Water Coils and Coaxial Heat Exchangers: The coaxial heat exchanger transfers heat between the refrigerant circuit and the water or ground loop, and buildup of scale or debris in the water loop over time can reduce its efficiency even without an outright failure. These parts see less exposure to outdoor contaminants than an air source coil, but water quality in the loop itself becomes the main variable affecting their condition. Confirming loop water quality and flow rate is a useful diagnostic step before assuming the heat exchanger itself has failed. Replacement is a more involved repair than most parts on this list due to the plumbing connections involved.

Buying Guide

Confirm the exact model number and cabinet configuration from the unit's nameplate before ordering, since ClimateMaster has produced multiple product families across residential and commercial applications and parts are not always interchangeable between them.

Read any fault codes displayed on the unit's control board before assuming which part has failed. These systems typically log codes tied to specific functions such as high pressure, low pressure, or sensor faults, which narrows the diagnosis considerably compared to a general no-heat or no-cool complaint.

When sourcing ClimateMaster Parts for a commercial building, confirm whether the loop is a shared water loop or dedicated ground loop system, since water quality and flow conditions differ between the two and affect which components see the most wear over time.

Because these systems have longer service lives than typical air source equipment, expect to service units that are considerably older than a comparable split system still in the field. Confirming current parts availability for an older model before committing to a repair versus a full unit replacement is a worthwhile step on aging installations.

Rule out water loop quality issues before replacing a coaxial heat exchanger outright, since scale or debris buildup in the loop can reduce performance without the part itself having failed.

Frequently Asked Questions

How long do ClimateMaster geothermal systems typically last compared to standard air source equipment?

Indoor units are commonly rated for service lives beyond twenty years, and ground loops can last more than fifty years, which is considerably longer than a typical air source system. This means service techs are often working on older equipment than they would encounter with standard split systems.

What is the difference between a water source and geothermal heat pump system?

Both trade an outdoor air source condenser for a water or ground loop, but a geothermal system uses buried ground loops while a water source system typically uses a shared water loop within a building. The core compressor, valve, and heat exchanger components serve the same function in both configurations.

Why does water loop quality matter for parts longevity?

The coaxial heat exchanger and other water-side components are directly exposed to whatever is circulating in the loop, so scale, debris, or poor water treatment can reduce component life and efficiency even without an outright failure. Checking loop water quality is a useful step before replacing a heat exchanger.

Can a fault code narrow down which part has failed?

Yes, ClimateMaster control boards typically log fault codes tied to specific conditions such as high pressure, low pressure, or sensor faults, which helps narrow diagnosis to a specific component rather than starting from a general no-heat or no-cool complaint.

Is a reversing valve failure always a full valve replacement?

Not necessarily. A valve that fails to fully shift between modes can sometimes resemble a control or sensor issue, so confirming the valve itself is the actual point of failure before ordering a replacement avoids swapping a part that was not actually broken.