
| Application: | Steam Boilers |
|---|---|
| Switch: | SPDT |
| Max Pressure (PSI): | 15 (Steam) |
| Type: | Electronic |
| Voltage: | 120v |
| Power Consumption: | 4 VA |
| Reset Type: | Automatic |
| Electrical Ratings (ALR): | 34.8 A @ 120 VAC (N.C) |
| Electrical Ratings (AFL): | 5.8 A @ 120 VAC (N.C) |
I had the same problem as you, but this is actually what this unit is supposed to do as it has a lock out on firing the boiler until reset it hit. The sell another unit without the lockout feature for use with an auto feed. When I put in the auto feed valve to remedy this problem I simple tied the two lead going to the reset switch together. This essentially prevents the lockout and my autofeed system was happy again.
I'm having an issue also and I have to manually add water. Water goes down very slow so I have not been able to see whether or not I am having the same issue with low water cutoff as you are. I'll try to see what is happening next time I change the water.
We recommend that you adjust the flow on the feeder or clean the probe.
Yes, this does include the probe.