Apply to be a TradeMaster!
Filter menu expanded

Filters

7 items
Reset

SORT

Product Availability
–

Show In Stock Only (7)

Size
–

1/2" (1)
3/4" (2)
1" (2)
1-1/4" (1)
1-1/2" (1)
2" (1)

Price Range
–

Under $1 (2)
$1 to $5 (5)

PVC Schedule 40 Adapters (SPG x MIPT)

Help Face
Need a little help?
7 items
Grid
List
Compare
Product Image of 1/2" PVC Sch. 40 Spigot x Male Adapter
1/2" PVC Sch. 40 Spigot x Male Adapter
SKU: 461-005
SKU: 461-005
(5)
$0.62 each
BOX UP & SAVE 8%
$28.50 box of 50
$0.57 each
In Stock
Get 49 by Tue, Nov 24
In Stock
Get 49 by Tue, Nov 24
Compare
Product Image of 3/4" PVC Sch. 40 Spigot x Male Adapter
3/4" PVC Sch. 40 Spigot x Male Adapter
SKU: 461-007
SKU: 461-007
(5)
$0.78 each
BOX UP & SAVE 9%
$35.50 box of 50
$0.71 each
In Stock
Get 145 by Tue, Nov 24
In Stock
Get 145 by Tue, Nov 24
Compare
Product Image of 1" PVC Sch. 40 Spigot x Male Adapter
1" PVC Sch. 40 Spigot x Male Adapter
SKU: 461-010
SKU: 461-010
(5)
$1.27 each
BOX UP & SAVE 10%
$57.00 box of 50
$1.14 each
In Stock
Get 197 by Tue, Nov 24
In Stock
Get 197 by Tue, Nov 24
Compare
Product Image of 1-1/4" PVC Sch. 40 Spigot x Male Adapter
1-1/4" PVC Sch. 40 Spigot x Male Adapter
SKU: 461-012
SKU: 461-012
(5)
$1.66 each
BOX UP & SAVE 8%
$38.00 box of 25
$1.52 each
In Stock
Get 50 by Tue, Nov 24
In Stock
Get 50 by Tue, Nov 24
Compare
Product Image of 1-1/2" PVC Sch. 40 Spigot x Male Adapter
1-1/2" PVC Sch. 40 Spigot x Male Adapter
SKU: 461-015
SKU: 461-015
(5)
$2.20 each
BOX UP & SAVE 12%
$48.25 box of 25
$1.93 each
In Stock
Get 150 by Tue, Nov 24
In Stock
Get 150 by Tue, Nov 24
Compare
Product Image of 2" PVC Sch. 40 Spigot x Male Adapter
2" PVC Sch. 40 Spigot x Male Adapter
SKU: 461-020
SKU: 461-020
(5)
$2.63 each
BOX UP & SAVE 10%
$59.50 box of 25
$2.38 each
In Stock
Get 48 by Tue, Nov 24
In Stock
Get 48 by Tue, Nov 24
Compare
Product Image of 1" x 3/4" PVC Sch. 40 Spigot x Male Adapter
1" x 3/4" PVC Sch. 40 Spigot x Male Adapter
SKU: 461-131
SKU: 461-131
(5)
$3.83 each
BOX UP & SAVE 12%
$168.50 box of 50
$3.37 each
In Stock
Get 200 by Tue, Nov 24
In Stock
Get 200 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Videos
Articles
More About PVC Schedule 40 Adapters (SPG x MIPT)

PVC Schedule 40 Adapters (SPG x MIPT) are fittings that convert a plain spigot pipe end into a male threaded connection, letting a solvent welded PVC run tie into a valve, pump, or fixture with iron pipe threads. Bodies are molded from PVC compound and rated for a maximum working temperature of 140 degrees Fahrenheit, which covers most cold and warm water, irrigation, and drain, waste, and vent applications. Fittings built for drain, waste, and vent service meet ASTM D2665, while pressure rated fittings for water lines meet ASTM D1785 and D2466. Because the spigot end glues directly into a coupling, tee, or hub fitting, no additional bushing or reducer is needed on that side of the joint. Contractors reach for this adapter whenever a plastic pipe run needs to land on threaded equipment, since it avoids cutting a thread onto PVC pipe or adding a second coupling to make the transition.

Subcategories

  • DWV Spigot x MIPT Adapters: Drain, waste, and vent adapters meet ASTM D2665 and are built for non pressurized drain and vent lines rather than potable water service. Plumbers use them to land PVC drain pipe on a threaded cleanout, trap adapter, or fixture connection. The spigot end solvent welds into standard DWV fittings while the MIPT end threads into cast iron or plastic drain hardware. Maximum working temperature stays at 140 degrees Fahrenheit, matching the rest of the Schedule 40 line.
  • Pressure Rated Adapters: Pressure rated spigot x MIPT adapters meet ASTM D1785 and D2466, qualifying them for cold and warm water distribution rather than gravity drain lines. Irrigation contractors and plumbers use them to transition solvent welded supply pipe onto a valve, pump, or hose bib with iron pipe threads. The same 140 degree Fahrenheit maximum temperature applies, so hot water lines need a different material. Choosing the pressure rated version over a DWV fitting matters when the line will operate under continuous water pressure.
  • Reducing Spigot x MIPT Adapters: Reducing adapters step down from a larger spigot pipe size to a smaller male threaded outlet, or the reverse, letting one fitting handle both the size change and the thread transition. They still carry the same 140 degree Fahrenheit maximum working temperature as straight sized adapters. Contractors use them to land oversized PVC branch lines onto smaller valves, gauges, or fixture connections without adding a separate bushing. Fewer joints on a retrofit run means fewer places for a leak to start.
  • Cleanout Adapters: Cleanout adapters pair a spigot x MIPT fitting with a threaded plug, giving a drain line a removable access point for snaking or inspection. They fall under the same ASTM D2665 DWV standard as other drain, waste, and vent fittings in the category. Plumbers install them at the base of a stack or at bends in the line where a blockage is most likely to form. The threaded plug can be removed and reinstalled repeatedly without damaging the PVC body.

Buying Guide

Selecting the right adapter starts with confirming whether the application is pressurized water supply or gravity drain, waste, and vent service, since the two use different ASTM ratings even though they look similar. Pressure rated adapters meet ASTM D1785 and D2466 and belong on irrigation, cold water, or warm water supply lines running under continuous pressure. DWV rated adapters meet ASTM D2665 and belong on drain and vent lines that only see intermittent flow at atmospheric pressure. Mixing the two ratings on the wrong application risks a joint failure even though the fittings can look identical on a shelf. Size matters on both ends of PVC Schedule 40 Adapters (SPG x MIPT), since the spigot side needs to match the outside diameter of the pipe it solvent welds into, while the MIPT side needs to match the female thread on the valve, pump, or fixture being connected. A reducing version handles jobs where the pipe size and the threaded connection size do not match, saving a separate bushing. Cleanout versions add a removable plug for jobs that need periodic access to the line. Temperature also factors into the decision, since all versions in this category top out at 140 degrees Fahrenheit, ruling them out for hot water heater discharge lines or other high heat applications. Checking the equipment's connection thread size before ordering avoids a mismatch that shows up only during installation.

Frequently Asked Questions

What is the difference between a spigot x MIPT adapter and a socket x MIPT adapter?

A spigot x MIPT adapter has a plain pipe sized end that solvent welds inside a fitting or coupling, while a socket version has a hub that the pipe itself glues into. PVC Schedule 40 Adapters (SPG x MIPT) are the right choice when the adapter needs to insert into an existing coupling, tee, or hub rather than receive a length of pipe. Mixing up the two ends leads to a joint that will not seat correctly during solvent welding.

Can these adapters handle hot water lines?

PVC Schedule 40 Adapters (SPG x MIPT) carry a maximum working temperature of 140 degrees Fahrenheit, which rules them out for water heater discharge piping or other high temperature service. Cold water supply, irrigation, and drain, waste, and vent lines all fall within that temperature range. A different pipe material is the better call whenever water temperature runs consistently above that limit.

Do these adapters need primer and cement on both ends?

Only the spigot end of the adapter needs PVC primer and cement, since that end solvent welds into a coupling, tee, or hub fitting. The MIPT end is a threaded connection that uses pipe thread sealant or tape instead of solvent cement. Applying cement to the threaded end by mistake will not create a seal and can damage the threads.

How do I know if I need a DWV adapter or a pressure rated adapter?

Drain, waste, and vent lines that only carry intermittent, gravity fed flow call for a DWV adapter built to ASTM D2665. Water supply lines running under continuous pressure, including irrigation and cold or warm water distribution, call for a pressure rated adapter built to ASTM D1785 and D2466. Checking the application against those two standards before ordering avoids installing the wrong rated fitting.

Are reducing spigot x MIPT adapters available for mismatched pipe and thread sizes?

Reducing versions of PVC Schedule 40 Adapters (SPG x MIPT) step the spigot size up or down from the MIPT size, covering jobs where the pipe run and the threaded connection are not the same size. They still carry the same 140 degree Fahrenheit maximum temperature rating as straight sized adapters. Using a reducing adapter avoids adding a separate bushing to make the size change.

Didn't find what you're looking for? 
Let us know
.