PVC Schedule 40 tees are three-port fittings that let a run of Schedule 40 PVC pipe branch into a third line. Spears white Schedule 40 PVC fittings conform to ASTM D2466, the standard specification for PVC plastic pipe fittings in Schedule 40, and to ASTM D1784, the specification for rigid PVC compounds. The Spears tee range includes socket configurations that solvent weld to pipe, reducing configurations that step the branch to a smaller size, and threaded configurations with FIPT or MIPT outlets. Listed tee sizes include 1/2", 3/4", 1", 1-1/4", 1-1/2", and 2". A tee sits at every branch point in a PVC system, so the connection type, size combination, and governing standard all matter before the first joint is cemented. Matching the fitting to the pipe and the mating components on the first pass saves rework, protects the job timeline, and keeps callbacks off the board for the installer.
Subcategories
Buying Guide
Start with the connection type, because it decides the tee configuration. Pick a socket tee when all three connections are PVC pipe, a reducing tee when the branch is smaller than the run, and a threaded tee when the branch connects to a threaded component. Confirm the thread gender on the mating part before ordering, since FIPT and MIPT outlets are not interchangeable.
Next, match the size. Read the run size first and the branch size second, and note both on the order so a reducing tee is not swapped for a straight one. Spears lists tee sizes that include 1/2", 3/4", 1", 1-1/4", 1-1/2", and 2".
Check the standard. Spears Schedule 40 fittings conform to ASTM D2466 and list NSF International certification, with NSF Standard 14 certifying suitability for potable water use. When a specification calls for a potable-rated fitting, confirm the marking on the fitting itself. When selecting PVC Schedule 40 tees, also confirm the pipe is Schedule 40 so the fitting and the pipe match.
Finally, plan the joint. Spears references ASTM D2855 as the practice for making solvent cemented joints with PVC pipe and fittings. Follow the cement manufacturer's instructions and the project specification for primer, cure time, and pressure testing. Order a few extra fittings in the sizes used most, since a mis-cut or misaligned joint cannot be reused once it is cemented.
Frequently Asked Questions
Do PVC Schedule 40 tees meet ASTM D2466?
Spears white Schedule 40 PVC fittings, including tees, conform to ASTM D2466, the standard specification for PVC plastic pipe fittings in Schedule 40. They also conform to ASTM D1784 for rigid PVC compounds. Check the marking on the fitting against the project specification.
Are PVC Schedule 40 tees rated for potable water?
Spears lists NSF International certification for its Schedule 40 PVC fittings, and NSF Standard 14 certifies suitability for potable water use. Confirm the NSF marking on the specific tee before using it on a potable line.
What's the difference between a socket tee and a threaded tee?
A socket tee has Socket x Socket x Socket connections that solvent cement to Schedule 40 PVC pipe. A threaded tee adds a FIPT or MIPT connection for a threaded component. PVC Schedule 40 tees in the threaded style need the thread type matched to the mating part.
When do I need a reducing tee?
Reducing PVC Schedule 40 tees step the branch outlet to a smaller size than the run. Use one when a smaller line branches from a larger one. Note both the run size and the branch size when ordering.
What sizes do PVC Schedule 40 tees come in?
Spears lists Schedule 40 tee sizes that include 1/2", 3/4", 1", 1-1/4", 1-1/2", and 2", along with larger sizes. The Spears page notes that not all products are listed, so confirm the exact size and connection type on the product page before ordering PVC Schedule 40 tees.