| Length (Feet): | 100' |
|---|---|
| Size: | 1/2" |
| Fitting System Compatibility: | PEX Press PEX Compression Clamp Push Fit Crimp |
| Material: | PEX |
| Grade: | PEX-b |
| Color: | White |
| Application: | Plumbing |
| Tubing Type: | Non-Oxygen Barrier |
| Warranty: | 25 Year |
No, you cannot use this tubing for compressed air, as PEX is neither rated nor tested for compressed air use.
If you have an open heating system, then yes, you could use this. However, since most heating systems are closed systems, this product generally cannot be used for what you describe.
We would recommend using 5/8" oxygen barrier PEX and spacing the tubing 9" on center.
100 feet of 1/2" PEX holds .92 gallons, so 1000 feet holds 9.2 gallons.
PEX cannot be used on a steam system.
The grade of this PEX tubing is PEX-b.
No, you cannot use PEX tubing to run natural gas. PEX is not tested or rated for use with natural gas.
Yes, this can be used on a pressure temperature relief valve as long as you do not exceed the rating on the PEX.
The maximum temperature is 200 Degrees Fahrenheit.
If water freezes in the line, then the line could burst. PEX is freeze resistant, not freeze-proof.