5/8" Oxygen Barrier PEX Tubing (1,000 ft Coil)

Brand:
Rifeng
SKU:
062-1000-OXY
Rating:
(272)
Q&A:
(102)
5/8" Oxygen Barrier PEX Tubing (1,000 ft Coil)
Magnifying glass
Hover image to zoom
Direct Replacement:
5/8" Oxygen Barrier PEX-b Tubing (1,000 ft Coil)
Brand:
Bluefin
SKU:T058-1000-OXY
(272)
VIEW REPLACEMENT
VIEW REPLACEMENT

Product Highlights

Product Highlight: Grade
PEX-b
Product Highlight: Tubing Type
Oxygen Barrier
Product Highlight: Fitting System Compatibility
Clamp, PEX Press, Push Fit, Crimp, PEX Compression
Product Highlight: Inside Diameter
0.574" ID
Product Highlight: Outside Diameter
0.75" OD
Product Highlight: Length (Feet)
1000' Length

Specs

Length (Feet):

1000'

Size:

5/8"

Color:

Red

Fitting System Compatibility:

Clamp

PEX Press

Push Fit

Crimp

PEX Compression

Material:

PEX

Grade:

PEX-b

Inside Diameter:

0.574"

Tubing Type:

Oxygen Barrier

Outside Diameter:

0.75"

Application:

Heating

Warranty:

25 Year

Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
MondayThursday
8am7:45pm
Friday
9am7:45pm
SaturdaySunday
9am5:45pm


Need help calculating?
Use Our Calculator

Product Reviews

4.57 out of 272 reviews
93% would recommend this product
4.57
out of 272 Reviews
93% would recommend this product
WRITE A REVIEW
5 star
75%
4 star
18%
3 star
2%
2 star
1%
1 star
4%
WRITE A REVIEW
Customer Images

Most Liked Positive Review

Decent pex tubing

Tubing is nicely priced and was a little hard to uncoil/unroll, more rigid and popped out of tracking sometimes but with three people it was easy to finish the job.Also found out that this style tubing doesn't have a friction barrier built in so it does make some noise when heating up and cooling off when strapping it down with the Uponor 1/2" pex rails. I was told when the mud floor gets laid down the expansion/contraction noises will not be heard.The company manufacture changed its name from Rifring to Bluefin for guys who like to do research,I don't know why? I would recommend this product BUT If I had to do it again I would tell someone the pro and cons and probably would have invested in a few more $$ into uponor's al-a-pex tubing because it was easier to work with when I did previous work to my radiant heating system
VS

Most Liked Negative Review

More brittle and difficult to handle than other pex I used

I bought 2000 feet of Mr. Pex 1/2" and 300 feet of this stuff ( by mistake ). When I ran out of Mr. Pex, I switched to this, and using it was much more difficult. It feels thinner, holds its coiled shape more, making it more difficult to lay out, and the ratchet cutter didn't really smoothly cut through, they seemed to apply pressure and eventually snap. In the end, it did its job and passed a pressure test no problem, but I was glad I only had to use it for one loop.
Showing 1-10 of 272 reviews

Has worked good for me. No complaints.

Used for Hydronic Floor heat. I love the ease of ordering from Supply House.
Ex. Sam (Don't use your real name)
ND
2 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Not all Pex-b is the same

I've used 100' and 300' rolls of 1/2 Pex-b from big box stores and I can say the Supply House Bluefin has superior surface finish quality. Box store material is dull and matte which is often very hard to pull through walls and other areas we install radiant heat lines. Bluefin has a gloss finish surface and it pulls like a dream, even for Pex-b
Mark G
West Michigan
5 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

was easy to install in extrusions

It is numbered every 5' from 1000' on down, making it easy to keep track of loop lengths. Water was coming out if it so I can presume they did a wet pressure test on the tubing.
Hoe Moaner
WA State
12 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

SQUEAKY!! And difficult to work with

I installed this tubing, used it for 1 week, and then replaced it all. Thermal expansion/contraction causes "tick, tick, tick" noises during temp changes at seemingly every point of contact with other materials, especially wood. I needed to pass these lines through floor joists, and the noise was so annoying on both floors. Unacceptable. It's also very stiff, doesn't bend easily, and the same sticky outside that causes the expansion noises makes it very difficult to pull through multiple joist holes, especially if they are misaligned at all. Do yourself a favor and buy Uponor hePEX. Yes, it's 3x the cost. Yes, it's worth that.
Tony
Golden, CO
1 years ago
Was this review helpful to you?

For the price it's worth it

This product does the job, although I find it's slightly more stiffer than other PEX B or C brands than are in my local stores (one heck of a lot stiffer than PEX A). After doing over 7,000 ft of this pipe…man, the stiffness gets annoying, but then I look back at the price and say it ain't so bad. There is laser printing on the pipe every few feet that tells you how much pipe you have left and just going off that unit of measurement each coil ends up having 15ish extra feet beyond the 1,000 ft mark. None of the coils had any defects, although there were a couple that had some rubbing marks within 1 feet of the end, but since each coil had an additional 15' this wasn't an issue. All in all, I'd buy this again mainly for the price and due to the really fast shipping speed from Supply House (2 days in my case)
Goody
Amarillo, Tex
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Best price in the USA

Using this Pex for radiant heat in a slab and found Bluefin to be the best price in the entire USA! This is PEX-B so it's way less flexible than A and is a bit harder to manage bends and such. I contemplated going with 5/8, but after messing around with 1/2 I'm glad I stuck with 1/2…I think the 5/8 would have been too much effort to bend and straighten out. The only con was that the roll did not have and feet measurement on it, so you have to be aware of your length as you go.
Goody
Amarillo
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Good price

In floor radiant heating.
Mike
E. Nassau, NY
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

O2 pex B

The only thing that would make it better, is if it straightened itself out. Decent price, great shipping time in my location.
jason
South east Ohio
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Good value

This roll of oxygen barrier pex is a good value for subfloor radiant heat. I am able to install it within joists 16" oc. using crimp rings where needed. Trying to find it locally is difficult. Supply House UPS shipping was fast and free with orders over $100.
Shom
Cortland, NY
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

I would buy again and recommend to all friends

used to run new lines to radiators replacing copper
aj
Adams Ma
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

102 Questions
102 Questions
ASK A QUESTION

Q: can this bend easily for ceiling installation 16inch centers what reflector system do you recomend

Asked by Robert 12 years ago

Add your answer

* Required Field
-

I used ½” pex under a floor that had engineered floor trusses at 24” on center. I was able to have three lengths of tubing between trusses without much difficulty. Having a helper to watch as the pex plays off the reel and at loop/return ends is helpful to prevent kinking the product. I used homemade aluminum fins for spreading the heat.

Was this review helpful to you?
-

The way it sits it is a bit stiff if you can put in in a big vat of hot water or a heat gun propane torch careful not to get it too hot were you need to make tight bends to soften it up and helps a lot. Mine was in the ground so cant help with the reflector.

Was this review helpful to you?

Q: can i use Uponor PROPEX expanding tool with this product?

Asked by MATTHEW 12 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

No, ProPEX fittings only work with PEX-A grade tubing (Rifeng PEX carries the PEX-B grade).

Was this review helpful to you?

Q: I want to use pex for hot water baseboard the rating is 180degrees but the boiler is usually set at 180 degrees for baseboard heat.With the boiler set at 180degrees will it affect the tubing

Asked by kevin 13 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Rifeng oxygen-barrier PEX is rated to 180°F at 100 psi, so you should not have any problems.

Was this review helpful to you?
-

This pex works very well for baseboard and fine at that temperature. I do this professionally and have installed thousands of feet of this and have never had a problem. Just used it to connect a wood boiler to air handlers and that is 190 degrees. Deepgreen Geothermal

Was this review helpful to you?
-

i believe it should be fine but check with pex to be sure. i have used it in heating systems with a range of 160f - 220f with no problems. it could be that pex is understating the limit for liability concerns.

Was this review helpful to you?
-

Hi Kevin: I used the 1" PEX tubing for heating which was rated for 200 degrees I run my Portage and Main Outdoor Furnace at 180degrees with no problems for a year now . I have had it up to 206 degrees for a short period with no problems except the tubing gets very soft. Fred

Was this review helpful to you?

Q: I am wanting to use the 1inch pex from brand rifeng and was wondering if is ok to use in outdoor wood burner set ups. the pipe will be in the ground and using a taco pump that puts out 125psi. i dont see any specs for this product. also will sharkbite fittings work for this pex

Asked by dude 13 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Rifeng PEX is only rated to 100 psi at 180°F fluid temperatures. It can handle higher pressures as temperatures drop. You should only use it if the system will operate within the tubing's specified temperature and pressure range.

Was this review helpful to you?
-

This Pex can can handle 100psi @ 180 degree water temp .... It will be perfectly fine for a outdoor boiler setup at long as you insulate it very well to prevent freezing ..... As far as the taco pump running 125psi that might be the specs to the max psi it can handle , a hot water boiler runs at 12-15 psi anyways. Sent from my iPhone

Was this review helpful to you?
-

We buried three coils of this same pipe, weren't sure about the sharkbite fittings so the pressure was left on for over a year with zero loss. !25 psi working pressure seems too ambitious especially since the woodburner heats in cycles and can get to temp. shutoff points.

Was this review helpful to you?
-

125psi is rather high. You should only see about 25 to 30 psi under normal situations. JOHN LADD

Was this review helpful to you?

Q: I'm running new baseboard heat in my home with two zones. I want to run the 3/4" oxygen barrier pex for the baseboard supply and return and where else needed. I will have 100ft to 125ft in one series with about 40ft of baseboard heat. The second will be 125ft to 150ft with about 35ft of baseboard heat. My question is will I have enough flow ratio to BTUs running PEX instead of copper? Will it be enough to heat my approximately 1000 sqft home?

Asked by Sean 13 years ago

Add your answer

* Required Field
-

3/4 pex will have the same flow characteristics as 3/4 copper and a substantially reduced heat loss from the exposed PEX so essentially I would expect it to perform as good or better than copper. Be certain to support it every other floor joist to help reduce the "telegraph" sag between hangers as the pex warms up. Sent on the Sprint® Now Network from my BlackBerry®

Was this review helpful to you?
-

You should have more then enough heat. I use 3/4 and run 150feet. Just give it time to heat everything up.

Was this review helpful to you?
-

3/4" will be fine as long as you are connecting all the baseboard of a zone "in series" (pipe feeds the first unit, out of the first unit into the second unit, out of the second unit into the next, out of the last unit to return to the boiler.) If you are running the units of a zone "in parallel", 3/4" is too small of a trunk. The distance causes no more heat loss than if you used copper. If you're still concerned, insulate the pipes. The volume contained in 3/4" copper is more than 3/4" pex, but the pex will still have sufficient heat for your amount of baseboard.

Was this review helpful to you?
-

The nice thing about PEX vrs. Copper is that the majority of the heat escapes through your baseboard radiators instead of the pipe. So in laying out your baseboard, you need to calculate each room, and determine the size of each baseboard. Make sure to place them on an exterior wall under the largest window in each room.

Was this review helpful to you?

Q: I am planning a new heating system and need help with what size pex pipe would be big enough to supply radiant heat to my radiators. 2000Sq ft. 75ft loops at the most cold climate.

Asked by steve 13 years ago

Add your answer

* Required Field
-

Yours is a complex question and there is simply not enough information to say with confidence which size PEX pipe you should use. If you are running separate lines to each radiator it is likely that the 1/2" PEX will be just fine.  The 1/2 inch PEX will typically handle flows up to 1 gpm easily and this equates to about 10,000 Btu/hr at a 20 degree temperature drop.   However, pipe size is best determined when you know the gpm and temperature requirement for each radiator.  For Example some radiators are rated at a flow rate of 1 gpm and 180 degrees.  If you intend to operate at a lower temperature using a condensing boiler the radiator Btu rating will be less than at 180 degrees and it may be necessary to circulate fluid at a higher rate to attain the needed Btus for that area.  I have some radiator circuits that are provided with 3/4 size PEX pipe simply because they need flows of 4 gpm or may be on circuits with several radiators in a series.  I know this does not answer your question but I hope it provides some background.  Here is a link to an excellent on-line manual on Understanding Hydronics that might be of some assistance in planning your heating system.   http://www.caleffi.us/caleffi/en_US/Site/Technical_library/Idraulica_magazine/args/detail/~Details~Magazines~magazine_detail_0000114/type/magazine/index.sdo

Was this review helpful to you?
-

I use 3/4 pex Sent from my iPad

Was this review helpful to you?

Q: Utility room is done (concrete poured) I will be poring he rest of the basement in 2 pours. 1 zone in the first pour (next to utility room). 2 zones in the second pour (20 ft from the utility room). A) Can i run feed lines to the zones in the second pour overhead vs buried in the first pour? B) I'm nervous about any "connection" other than hooking to a manifold. I would never burry a connection, but am I being too fussy about an additional above ground connection?

Asked by QuackAttack 13 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

It would be okay to feed lines overhead or through the wall back to the manifold. It is ideal not to have any connections between the supply and return of the manifold (especially in the slab), but PEX fittings are usually quite reliable.

Was this review helpful to you?
-

I haven't had to make joints in concrete but I've heard repairs are butt spliced and poured over. If you are worried about the concrete corroding the bands and possibly leaking you could put heat shrink over the join as an added precaution. Hope this helps

Was this review helpful to you?

Q: What type Pex tubing should I use? I have a 120 gallon stoned lined solar-closed loop hot water tank and a 42 gallon electric tank for domestic hot water. Can I hook up to these and what Pex tubing should I use?

Asked by will 13 years ago

Add your answer

* Required Field
-

Oxygen barrier

Was this review helpful to you?
-

the O2 barrier pex should be dedicated for the "Closed Loop" system, because you never want oxygen to prematurely corrode the components in your solar system. As far as the domestic hot water, typical pex rated for "Potable" water is used.I would recommend using 3/4" for both projects. ( which is also much cheaper in price)

Was this review helpful to you?
-

The closed loop to the solar panel should be pex with an oxygen barrier as long as it contains water only. If there is any other content, glycol, or similar, then pex won't handle the higher heat but water alone is fine. The domestic water can use any pex, including oxygen barrier.

Was this review helpful to you?
-

The type of PEX you use depends on how you choose to use the hot water in the tanks.  If this is for domestic hot water distribution to bathrooms; tubs, sinks, etc. then the plumbing inspector will be looking for an NSF indication on the tube wall to show that it is approved for domestic hot water distribution.  If however you are using it for radiant heat then the oxygen  barrier tube you are showing in the question is quite adequate.  A word of caution.....beware any issues with solar stagnation.  A panel that has no circulation during a power outage can easily rise in temperature to well above the boiling point and exceed the thermal and pressure limitations of pex tube.  Any connections between a solar panel and a storage tank need to be with copper or a tube material that can tolerate these super high temperatures.  

Was this review helpful to you?

Q: I understand my loops should not exceed 300 ft, what if I have two loops on one zone, first loop is 300 ft second loop is 150 ft. How would I make this work? Also if I have one loop on one zone this loop can be any length under 300 ft right?

Asked by Pat 13 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The 300-foot maximum is a rule-of-thumb with 1/2" PEX. There are systems in which shorter maximums should be observed and others in which loops longer than 300' would be okay. When loops have widely varying lengths, you should use a manifold with balancing valves to regulate the flow to each line.

Was this review helpful to you?

Q: What is the best way to repair a kink when installing rifeng in floor radiant applacation?

Asked by pat 13 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Heating the tubing can help, but you may need to insert a repair coupling when using PEX-B grade tubing.

Was this review helpful to you?
-

I use a "hot air gun".  Straighten the kink area and carefully heat the full circumference of the tube at the kink.  The tube will swell slightly as it warms. Once it us uniform and no longer shows any indentation of the kink remove the heat gun and let it cool slowly.  This will allow the PEX tube to reassume its original molecular structure with no distortion or weakness that was created by the original kink.  

Was this review helpful to you?
-

using a heat gun or torch, gently warm up the kinked area (Without melting it!) the cross linked properties of pex will return it to its original state. Allow it to cool naturally before further installation.

Was this review helpful to you?