Robertshaw Pilot Ignition Uni-Kits are intermittent pilot ignition system kits from the Robertshaw 712 Series, made for natural gas systems. The series uses flame rectification with solid-state logic and flame sensing to provide automatic sequencing for an intermittent pilot ignition device. Each model pairs a specific ignition control with a specific gas valve. Model 712-008, for example, has a 150,000 BTU capacity, a 720-070 gas valve and a 780-845 lockout control. The lineup also includes models 712-006, 712-009, 712-016 and 712-017, and the series is offered with one of four different gas valve types to fit a wide range of furnace applications. Robertshaw states that the 712 Series must not be used on LP gas applications. Matching the control type, valve size and input rating to the furnace being serviced matters because the kit decides how the system responds to a failed ignition attempt.
Subcategories
Buying Guide
Start with the existing ignition control and gas type, because those two facts rule out most of the lineup. Every 712 Series kit is for natural gas only, and Robertshaw states not to use the series on LP gas applications. Next, decide between lockout and nonlockout operation. Models 712-006, 712-008 and 712-009 use the 780-845 control with 90 second lockout timing. Models 712-016 and 712-017 use the 780-715 control with nonlockout restart.
Gas valve connection size comes next. Models 712-008 and 712-017 have a 1/2 inch inlet and a 3/4 inch outlet, models 712-006 and 712-016 have 3/4 inch inlet and outlet, and model 712-009 has 1 inch inlet and outlet. Confirm the size against the piping already on the furnace before ordering.
Input capacity is the last filter. Listed capacities include 150,000 BTU on model 712-008, 200,000 BTU on model 712-017 and 350,000 BTU on model 712-016. Compare the figure with the furnace nameplate input rather than assuming a kit fits because the connections match.
When comparing Robertshaw Pilot Ignition Uni-Kits, verify every model number, capacity and valve against the manufacturer data before committing to a kit. Robertshaw lists complete instructions and troubleshooting information with the 712 Series, so keep the installation documentation with the furnace record after the repair.
Frequently Asked Questions
Can Robertshaw pilot ignition Uni-Kits be used on LP gas?
No. Robertshaw Pilot Ignition Uni-Kits in the 712 Series carry a caution not to use them on LP gas applications. The kits are for natural gas systems only.
What is the difference between the 780-845 and 780-715 controls?
In the Robertshaw 712 Series, the 780-845 control is a lockout control with 90 second lockout timing, and the 780-715 control is nonlockout. Models 712-006, 712-008 and 712-009 use the 780-845. Models 712-016 and 712-017 use the 780-715.
How does a 712 Series pilot ignition kit sense flame?
Robertshaw 712 Series pilot ignition kits use flame rectification with solid-state logic and flame sensing. The combination provides automatic sequencing for an intermittent pilot ignition device.
Which gas valves do the Robertshaw 712 Series kits use?
Robertshaw Pilot Ignition Uni-Kits are offered with one of four different gas valve types. Models 712-006 and 712-016 use the 700-056 valve, model 712-009 uses the 700-059 valve, and models 712-008 and 712-017 use the 720-070 valve.
Does the Robertshaw 712-008 restart after a failed ignition attempt?
Robertshaw lists the 712-008 pilot ignition kit with a 3 try lockout restart and 90 second lockout timing. It is a 150,000 BTU kit with a 720-070 gas valve and a 780-845 control. The nonlockout models, 712-016 and 712-017, restart without a lockout.