Series 800 Line Voltage Robertshaw Thermostats are mechanical, mercury-free thermostats built to control electric baseboard, unit heaters, and other line voltage heating and cooling loads directly, without a separate low-voltage transformer or relay. The line is rated for 120V, 240V, and 277V AC, covering most electric heat circuits found in residential and light commercial buildings. Bimetal temperature sensing drives the switching action, and a positive-off setting lets a technician kill power to the connected load directly at the thermostat rather than at the breaker. J-box compatible mounting speeds up installation on both new construction and retrofit jobs, since the thermostat body fits standard electrical boxes already in the wall. Robertshaw markets this series as a universal replacement for many other brands' line voltage thermostats, which matters on service calls where the original model has been discontinued. Because the switching happens right at line voltage, verifying the connected load's amperage against the thermostat's rated capacity before installation avoids nuisance tripping or premature switch failure.
Subcategories
Buying Guide
Choosing the right model in this lineup starts with the circuit already in the wall. A single hot leg calls for the SPST Model 801, while a 240V circuit with two hot legs to switch calls for the DPST Model 802. Wiring a single-pole thermostat onto a double-pole circuit leaves one leg energized even with the thermostat switched off, a safety issue on any service call.
Heating versus cooling is the next split. Series 800 Line Voltage Robertshaw Thermostats include both heating models, 801 and 802, and a dedicated cooling model, 803A, so confirming which load the thermostat controls before ordering prevents a mismatched switch rating on the job.
Load capacity matters on circuits feeding larger heaters or contactors. Model 801 carries a 1/4 HP rating at 120V AC and 1/3 HP at 240V AC, with 125VA pilot duty available for switching a contactor coil rather than the full heating load directly. Checking the connected equipment's nameplate amperage against these ratings before wiring avoids overloading the internal switch contacts.
Canadian jobs requiring CSA certification instead of UL listing should specify the C802 or C803 variants rather than the standard US models, since the switch mechanisms are certified separately.
Finally, since these thermostats are mercury-free with bimetal sensing rather than a mercury bulb, no special handling or disposal procedure applies during removal, simplifying replacement work on older buildings still running mercury switches on other equipment.
Frequently Asked Questions
What's the difference between the Robertshaw 801 and 802 line voltage thermostats?
Model 801 is a single pole (SPST) thermostat built for circuits with one hot leg, while Model 802 is a double pole (DPST) thermostat that switches both legs of a 240V circuit at once. Wiring a single-pole 801 onto a two-leg circuit leaves one leg energized even when the thermostat reads off, so matching the pole count to the circuit matters for safety. Model 801 also carries published ratings of 1/4 HP at 120V AC and 1/3 HP at 240V AC.
Do Series 800 Robertshaw thermostats need a separate low-voltage transformer?
Series 800 Line Voltage Robertshaw Thermostats switch line voltage directly, so no separate low-voltage transformer or relay is needed to operate them. Power to the connected heating or cooling load runs straight through the thermostat's internal switch contacts. Direct switching at line voltage is why matching the thermostat's voltage rating, 120V, 240V, or 277V AC, to the circuit matters before installation.
Are Robertshaw 800 Series thermostats mercury-free?
Series 800 Line Voltage Robertshaw Thermostats use bimetal temperature sensing rather than a mercury bulb, making the entire line mercury-free. No special handling or disposal procedure applies when removing one of these thermostats, unlike older mercury-switch models still found in some buildings. Bimetal sensing also holds up on retrofit jobs without the leveling requirement mercury switches need during installation.
Is there a cooling model in the Robertshaw 800 Series line?
Model 803A is the dedicated cooling thermostat in the Series 800 line, built as a single pole (SPST) switch for line voltage cooling loads like window units or PTAC systems. Models 801 and 802 are heating-only thermostats and shouldn't be used to control cooling equipment. A Canadian equivalent, model C803, covers the same cooling application for CSA-certified installations.
Can Robertshaw 800 Series thermostats replace other brands' line voltage thermostats?
Series 800 Line Voltage Robertshaw Thermostats are built as universal replacements for many other brands' line voltage thermostats, which helps on service calls where the original installed model has been discontinued. J-box compatible mounting means the replacement thermostat fits standard electrical boxes already in the wall without new rough-in work. Confirming pole count, SPST or DPST, and voltage rating against the old unit still matters before swapping one in.