SetPoint Controls are Taco's line of microprocessor-based mixing valves and variable speed circulators built to hold a fixed hydronic supply temperature no matter how conditions in the system change. The iSeries SetPoint mixing valve modulates a 2-way, 3-way, or 4-way ball valve to blend boiler water down to a set delivery temperature, with a fluid temperature range of 20°F to 240°F and an adjustable setpoint dial spanning 80°F to 180°F. A companion line of 00 Series variable speed circulators can hold that same fixed supply temperature, maintain a set differential between two sensor locations, or step in as a bypass pump, all without a separate outdoor reset control. For contractors, that means one control assembly handles boiler protection, radiant floor temperature limiting, and snowmelt loops without stacking extra aquastats or mixing stations. Choosing the right SetPoint Controls product cuts callbacks tied to overheated radiant slabs or condensing boiler flue gas issues.
Subcategories
Buying Guide
Start by deciding what the system needs to hold steady: a fixed supply temperature, a set temperature differential, or both. A radiant floor or snowmelt loop that can't tolerate full boiler temperature calls for an iSeries mixing valve, since it modulates its own valve position to blend water down to the setpoint dial's range. A system that instead needs the pump itself to track a load, such as a fan coil or a primary/secondary loop, calls for a 00 Series variable speed circulator running in fixed-temperature or differential mode. Sizing SetPoint Controls correctly means matching the valve or circulator's pressure and flanged connection size to the existing piping, then confirming the fluid temperature range covers the boiler's actual operating range rather than just its design point. Contractors mixing radiant zones with a condensing boiler should pay close attention to the low end of the valve's setpoint dial, since protecting the boiler from flue gas condensation depends on holding return water above the manufacturer's minimum. Replacement work is usually simpler than new installation: because the actuator separates from the valve body with one hand, a tech can swap a failed actuator without cutting into the piping. Keep a spare actuator and a couple of sensor leads on the truck for planned mixing valve service calls, since those are the components most likely to fail before the valve body itself does.
Frequently Asked Questions
What's the difference between a SetPoint mixing valve and a standard boiler reset control?
A SetPoint mixing valve modulates its own 2-way, 3-way, or 4-way valve position to hold a fixed water supply temperature between 20°F and 240°F, with the microprocessor control built into the actuator itself. A standard reset control instead adjusts boiler firing based on outdoor temperature and doesn't blend water at the valve. Radiant and snowmelt zones typically need the mixing valve regardless of what reset strategy the boiler uses.
Can a SetPoint circulator replace a mixing valve on a radiant zone?
A SetPoint circulator can hold a fixed supply temperature or a set differential in some configurations, which covers similar ground to a mixing valve on certain fan coil and primary/secondary setups. A zone with a wide gap between boiler and floor temperature still needs a mixing valve to blend the water down safely. Checking the zone's actual temperature spread before substituting one for the other avoids an undersized fix.
What voltage do SetPoint mixing valve actuators run on?
SetPoint mixing valve actuators run on 24 VAC, plus or minus 10 percent, at 50 or 60 Hz, drawing about 0.4 amps. The control voltage matches most residential and light commercial zone control transformers already on the boiler. Confirming the transformer's VA rating before adding a SetPoint valve keeps the added draw from overloading an existing control circuit.
How does a SetPoint actuator get serviced without draining the system?
The SetPoint actuator separates from the valve body with a one-hand release, so a tech can pull it for service without cutting into the piping or draining the loop. The valve body itself stays in the line while the actuator is off, since it's the ball or plug element doing the sealing. Swapping in a spare actuator restores the multi-status LED and setpoint dial function in minutes rather than hours.
What's the setpoint range on a SetPoint mixing valve dial?
The adjustable setpoint dial on a SetPoint mixing valve runs from 80°F to 180°F, within an overall fluid temperature range of 20°F to 240°F. An optional 15°F night setback can drop the supply temperature further during unoccupied periods. Setting the dial too close to the fluid range's upper limit leaves little margin for a boiler that runs hotter than expected under load.