Strap-On Thermostats are temperature controls that strap onto a pipe to sense supply media temperature and switch an electrical circuit. The Barber Colman TC-2931 changeover model holds a fixed 75 degrees F setpoint with a 15 degrees F differential. On combination heating and cooling air conditioning units, changeover thermostats sense supply media temperature and reverse the control action of the room temperature sensing element. The TC-2974 covers 50 to 210 degrees F and opens or closes a circuit when pipe temperature exceeds the setting. Its common-normally closed circuit is often used on unit heater installations to hold the fan off until heat is actually present, and its common-normally open circuit is usually used for control on hot water boilers. Matching the right strap-on model to the application keeps unit heaters, changeover controls and boilers responding to real pipe temperature.
Subcategories
Buying Guide
Start with the job the thermostat has to do. Changeover duty on a combination heating and cooling unit calls for a changeover model such as the TC-2931 or TC-2942, which sense supply media temperature and reverse the control action of the room temperature sensing element. Pipe temperature switching for unit heaters or hot water boilers calls for a model such as the TC-2974.
Next, match the temperature behavior. The TC-2931 and TC-2942 list a fixed 75 degrees F with a 15 degrees F differential. The TC-2974 covers 50 to 210 degrees F, so confirm the operating pipe temperature sits inside that range.
Then check the circuit and wiring. On the TC-2974, the common-normally closed circuit is often used on unit heater installations to hold the fan off until heat is present, and the common-normally open circuit is usually used for hot water boiler control. The TC-2942 is an enclosed type with a 1/2 inch conduit adapter, SPDT output, and three color coded 16 gauge leads that are 3 feet long. It lists 120/240V.
When comparing Strap-On Thermostats, also note construction. The TC-2942 is hermetically sealed and uses a fast responding bimetal element with silver contacts. Its body measures 2 inches in diameter by 1-1/2 inches high, which matters when clearance around the pipe is limited.
Finally, read the full product page for each model before ordering, since specifications differ by thermostat.
Frequently Asked Questions
What is a changeover strap-on thermostat used for?
Changeover strap-on thermostats are used primarily on combination heating and cooling air conditioning units. They sense supply media temperature and reverse the control action of the room temperature sensing element. The Barber Colman TC-2931 is a fixed 75 degrees F model.
What temperature range does the TC-2974 strap-on thermostat cover?
The Barber Colman TC-2974 strap-on thermostat covers 50 to 210 degrees F. It opens or closes electrical circuits when the pipe temperature exceeds the thermostat setting. Confirm the system's operating temperature falls inside that range.
Which circuit should I use on a unit heater with a strap-on thermostat?
On strap-on thermostats like the TC-2974, the common-normally closed circuit is often used on unit heater installations. It prevents fan operation unless heat is present at the pipe. The common-normally open circuit is usually used for hot water boiler control.
Do strap-on thermostats come with a conduit connection?
The Barber Colman TC-2942 strap-on thermostat is an enclosed type with a 1/2 inch conduit adapter. It also has three color coded 16 gauge leads that are 3 feet long. Other strap-on models differ, so verify the connection style on each product page.
What is the differential on Barber Colman changeover strap-on thermostats?
The Barber Colman TC-2931 and TC-2942 strap-on changeover thermostats list a 15 degrees F differential and a fixed 75 degrees F. The TC-2942 also lists 120/240V and a snap-acting SPDT switch with silver contacts.