Apply to be a TradeMaster!
Filter menu expanded

Filters

414 items
Reset

SORT

Product Availability
–

Show In Stock Only (228)

Brand
–

AO Smith (36)
Bluefin (4)
Bosch (37)
DiversiTech (13)
DuraVent (1)
Eccotemp (3)
IPEX (12)
Kozy Kollar (4)
Noritz (127)
Oatey (45)

Product Type
–

Adapter (21)
Adjustable Pipe (11)
Backflow Preventer (2)
Birdscreen (4)
Bracket (5)
Bug Guard (2)
Concentric Kit (4)
Condensation Drain (5)
Conversion Kit (6)
Cosmetic Ring (4)

Vent Type
–

Concentric (87)
Condensing (38)
Double Wall (16)
Non-Condensing (35)
PVC (2)
Single Wall (91)
Vent Kit (1)

Price Range
–

$1 to $5 (12)
$5 to $10 (27)
$10 to $15 (27)
$15 to $20 (14)
$20 to $25 (10)
$25 to $30 (12)
$30 to $35 (20)
$35 to $40 (5)
$40 to $45 (19)
$45 to $50 (13)

Tankless Heater Venting

Help Face
Need a little help?
414 items
Grid
List
Compare
Product Image of 4" Z-Flex Vent Adapters (Pack of 6)
4" Z-Flex Vent Adapters (Pack of 6)
SKU: 2SVAM4
Z-FLEX
SKU: 2SVAM4
Brand: Z-FLEX
$375.78 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of 5" Novavent Vertical Drain Pipe
5" Novavent Vertical Drain Pipe
SKU: 2NVVD5
Z-FLEX
SKU: 2NVVD5
Brand: Z-FLEX
$72.48 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PP Cascade Vent Horizontal Termination Dia6" For Therm 1210 & Greentherm
$439.13 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Vent Elbow Pp 80/125 90-Degree
Concentric Vent Elbow Pp 80/125 90-Degree
SKU: 7738003242
Bosch
SKU: 7738003242
Brand: Bosch
$137.79 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Vent Extension PP 80/125 x 20"
Concentric Vent Extension PP 80/125 x 20"
SKU: 7738003239
Bosch
SKU: 7738003239
Brand: Bosch
$112.19 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Vent Kit Pp 100/150. Gb162
Concentric Vent Kit Pp 100/150. Gb162
SKU: 7738004825
Bosch
SKU: 7738004825
Brand: Bosch
$453.34 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 5355 Concentric Flashing
5355 Concentric Flashing
SKU: 7747204814
Bosch
SKU: 7747204814
Brand: Bosch
$144.39 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Flat Roof Flashing 015
Flat Roof Flashing 015
SKU: 87094912
Bosch
SKU: 87094912
Brand: Bosch
$159.03 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of PP Cascade Vent 90-Degree Elbow Dia6" For Therm 1210 & Greentherm
$64.16 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Vent Extension PP 100/150 x 2000
Concentric Vent Extension PP 100/150 x 2000
SKU: 7738004830
Bosch
SKU: 7738004830
Brand: Bosch
$272.00 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Vent Fire Stop Support Al 150
Concentric Vent Fire Stop Support Al 150
SKU: 7738004836
Bosch
SKU: 7738004836
Brand: Bosch
$26.58 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Wall Thimble for Horizontal Termination Kit (Builder's Edition)
$71.11 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Vertical Vent Kit
Concentric Vertical Vent Kit
SKU: CVK-V-1-F
Noritz
SKU: CVK-V-1-F
Brand: Noritz
$333.80 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 8.3" - 11.2" Concentric Adjustable Vent Pipe
8.3" - 11.2" Concentric Adjustable Vent Pipe
SKU: CVP-11ADJ
Noritz
SKU: CVP-11ADJ
Brand: Noritz
$81.25 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Concentric Straight Birdscreen
Concentric Straight Birdscreen
SKU: CVT-S
Noritz
SKU: CVT-S
Brand: Noritz
$83.35 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Angled Roof Flashing with Vertical Roof Member
$58.91 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Stainless Steel Pipe Cover for NC380
Stainless Steel Pipe Cover for NC380
SKU: PC-4S-SUS
Noritz
SKU: PC-4S-SUS
Brand: Noritz
$206.75 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 4" Rain Cap (Single Wall)
4" Rain Cap (Single Wall)
SKU: FSRC4
DuraVent
SKU: FSRC4
Brand: DuraVent
$206.83 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 6" Clearance Support Straps (Pack of 10)
$33.50 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Rain Cap with Vertical Termination
Rain Cap with Vertical Termination
SKU: RC5-NORITZ
Noritz
SKU: RC5-NORITZ
Brand: Noritz
$104.72 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 4" Support Clamp (Pack of 5)
$31.19 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 5" Support Clamp (Pack of 5)
$33.50 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 6" Straight Vent Pipe
6" Straight Vent Pipe
SKU: VP5-6STRAIGHT
Noritz
SKU: VP5-6STRAIGHT
Brand: Noritz
$21.40 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 24" Straight Vent Pipe
24" Straight Vent Pipe
SKU: VP5-24STRAIGHT
Noritz
SKU: VP5-24STRAIGHT
Brand: Noritz
$51.97 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Horizontal Vent Termination with Louvre
$146.77 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Horizontal Vent Termination with 45° Birdscreen
$42.27 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Horizontal Vent Termination with Straight Birdscreen
$32.56 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of 7"-14" Wall Thickness Horizontal Termination Kit
7"-14" Wall Thickness Horizontal Termination Kit
SKU: VK4-H-14-1
Noritz
SKU: VK4-H-14-1
Brand: Noritz
$299.15 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Compare
Product Image of Vent Extension 6-39, 790089
Vent Extension 6-39, 790089
SKU: 790089
Rinnai
SKU: 790089
Brand: Rinnai
$57.59 each
In Stock
Get 1 by Mon, Nov 30
In Stock
Get 1 by Mon, Nov 30
Compare
Product Image of Condensing Tankless Recess Box for Ultra Series (KB and KBP Models Only)
$597.69 each
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Backorder
Get it by Wed, Dec 23 - Tue, Jan 26
Resources
FAQs, Manuals & Videos
Videos
Articles
More About Tankless Heater Venting

Tankless heater venting is the piping, fittings, and termination hardware that carries combustion exhaust away from a tankless water heater and, on many models, draws in fresh combustion air at the same time. Direct vent and power vent tankless units typically call for PVC, CPVC, or stainless steel vent pipe rated for the unit's specific temperature and pressure requirements, since standard water heater venting wasn't designed to handle sustained flue gas exposure at the higher efficiencies tankless equipment runs at. A concentric vent kit combines the intake and exhaust into a single wall or roof penetration, which simplifies installation in tight mechanical rooms where running two separate penetrations isn't practical. Getting the venting material, diameter, and maximum run length right matters as much as the water heater itself, because manufacturers void warranties when installers use unapproved venting or exceed a unit's rated vent length. Replacing failed or corroded venting components promptly keeps a tankless system running at its rated efficiency and prevents exhaust leakage into occupied space.

Subcategories

  • PVC and CPVC Vent Pipe: PVC and CPVC vent pipe fits non-condensing and lower-temperature direct vent tankless water heaters where the manufacturer's installation manual specifically lists that material as approved. Installers glue and fit these runs using standard plumbing techniques, which keeps material and labor costs down compared with metal venting. Vent pipe here still needs to match the exact diameter called for in the unit's manual, since undersized runs restrict exhaust flow and can trigger a flame-failure lockout. Contractors check the maximum approved run length before finalizing a layout, since PVC and CPVC systems typically carry tighter length limits than stainless steel alternatives.
  • Stainless Steel Vent Pipe: Stainless steel vent pipe handles the higher flue gas temperatures found in some non-condensing and combination direct vent or power vent tankless units, where plastic venting isn't an approved option. The material resists the corrosive condensate that forms as exhaust gas cools inside the pipe, which extends service life in installations with long horizontal runs. Stainless sections use band or twist-lock connections rather than solvent welding, so installers need matching couplers and elbows from the same product line to keep every joint sealed. Longer approved run lengths make stainless steel useful in mechanical rooms set back from an exterior wall.
  • Concentric Vent Kits: Concentric vent kits combine the combustion air intake and exhaust into one pipe assembly, routing through a single wall or roof penetration instead of two separate ones. Tight mechanical closets and remodels where cutting a second penetration isn't practical benefit most from this configuration. The kit's termination cap keeps intake air and exhaust gas properly separated at the outside wall so exhaust isn't drawn back into the intake stream. Confirming the kit matches the tankless unit's rated diameter and maximum vent length keeps the installation within the manufacturer's approved configurations.
  • Vent Terminations and Wall or Roof Caps: Vent terminations and wall or roof caps are the fittings installed where combustion exhaust exits the building, sized and clearance-rated to keep exhaust gas away from windows, soffits, and adjacent structures. Manufacturers publish minimum clearance distances from grade, walkways, and building openings that terminations need to meet at installation. A termination that isn't rated for the local snow line or roof pitch can allow blockage during winter months, a common cause of nuisance shutdowns. Replacing a cracked or corroded termination cap protects the rest of the vent run from moisture intrusion.
  • Buying Guide

    Matching venting material to the specific tankless water heater model is the first step in any vent replacement or new installation, since manufacturers approve only certain pipe types, diameters, and maximum run lengths for each unit. Installation manuals list these requirements explicitly, and using an unapproved material or exceeding a rated run length can void the equipment warranty even when the water heater itself is functioning correctly.

    Vent diameter and configuration depend on whether the unit is non-condensing or condensing, and whether the installation calls for a single exhaust pipe or a concentric intake and exhaust assembly. Tankless heater venting components need to stay consistent across an entire run. Mixing PVC fittings with a stainless steel section, for example, isn't an approved configuration on most equipment and creates a point where condensate or exhaust gas can leak.

    Termination placement matters beyond the equipment itself. Local clearance requirements govern how far a vent termination sits from windows, doors, walkways, and property lines, and roof terminations need enough height and protection to avoid snow or debris blockage. Contractors planning a longer run should total the equivalent length of every elbow and fitting against the manufacturer's maximum approved distance before ordering pipe, since exceeding that limit restricts draft and can trigger safety lockouts on the unit.

    Frequently Asked Questions

    What venting material is approved for a condensing tankless water heater?

    Condensing tankless units typically approve PVC, CPVC, or polypropylene venting because flue gas temperatures stay low enough for plastic pipe to handle safely. The specific approved material and maximum run length varies by manufacturer and model, so checking the installation manual before ordering pipe avoids installing venting that voids the warranty.

    Can PVC vent pipe be used on a non-condensing tankless unit?

    Non-condensing units run hotter exhaust temperatures that most PVC pipe isn't rated to handle, so these installations typically call for stainless steel or another high-temperature material instead. Installing PVC on a non-condensing unit against the manufacturer's specifications creates a safety hazard and voids coverage.

    What's the benefit of a concentric vent kit over separate intake and exhaust pipes?

    A concentric vent kit routes combustion air intake and exhaust through a single wall or roof penetration, cutting the number of holes needed in the structure and simplifying termination clearance planning. Installations in tight mechanical closets or finished spaces often favor this configuration for that reason.

    How is maximum vent run length calculated for a tankless water heater?

    Manufacturers publish a maximum equivalent length that accounts for straight pipe runs plus an additional distance for each elbow or fitting in the system. Adding up every component's equivalent length against the published maximum keeps the completed run within the unit's rated draft capacity.

    What causes a tankless water heater to shut down with a venting-related error code?

    Blocked terminations, undersized pipe diameter, or exceeding the maximum approved run length are common causes of exhaust or intake restriction that trigger a safety lockout. Checking the termination for debris or snow buildup and confirming the vent run matches the manual's specifications typically resolves the issue.

Didn't find what you're looking for? 
Let us know
.