Apply to be a TradeMaster!
Filter menu expanded

Filters

161 items
Reset

SORT

Product Availability
–

Show In Stock Only (42)

Used With
–

68 Boilers (1)
76 Boilers (1)
78 Boilers (1)
80 Boilers (1)
AHE Boilers (5)
CG Boilers (3)
CGa Boilers (2)
CGi Boilers (4)
CGs Boilers (4)
CGT Boilers (2)

Review Score
–

(35)
(1)
(1)
(1)

Price Range
–

$5 to $10 (3)
$10 to $15 (8)
$15 to $20 (5)
$20 to $25 (2)
$25 to $30 (2)
$30 to $35 (6)
$35 to $40 (8)
$40 to $45 (7)
$45 to $50 (5)
$50 to $60 (11)

Weil McLain GV Boiler Parts

Help Face
Need a little help?
FIND PARTS FOR YOUR UNIT
161 items
Grid
List
Compare
Product Image of Repair Kit, Front Section, 382-200-300
Repair Kit, Front Section, 382-200-300
SKU: 382-200-300
Weil-McLain
SKU: 382-200-300
Brand: Weil-McLain
$483.31 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Repair Kit, Block Repair Kit, 382-200-391
Repair Kit, Block Repair Kit, 382-200-391
SKU: 382-200-391
Weil-McLain
SKU: 382-200-391
Brand: Weil-McLain
$423.40 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Condensate drain line check valve kit, 382-200-406
$574.52 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Kit-S Panel-T Jacket GV90+ 3-4, 382-200-700
$175.94 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Jacket Panel, Front for GV90+ Boilers, 382-200-702
$123.08 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Compare
Product Image of Circulator Hardware Kit, 381-354-525
Circulator Hardware Kit, 381-354-525
SKU: 381-354-525
Weil-McLain
SKU: 381-354-525
Brand: Weil-McLain
$98.29 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Wiring Harness, Control Module to Circulator for GV Boilers, 591-391-818
$47.63 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Wiring Harness, Control Module to: Thermostat, Block Switch, Limit, Pressure Switch, Gas Valve - for GV Boilers, 591-391-820
$79.52 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Jacket Hardware Kit, 569-928-025
Jacket Hardware Kit, 569-928-025
SKU: 569-928-025
Weil-McLain
SKU: 569-928-025
Brand: Weil-McLain
$43.20 each
Backorder
Get it by Mon, Jan 4 - Tue, Feb 2
Backorder
Get it by Mon, Jan 4 - Tue, Feb 2
Compare
Product Image of WELL LMT 1/2" Honeywell 123869A, 592-300-017
$32.44 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Cover Eco 5-6, 593-000-003
Cover Eco 5-6, 593-000-003
SKU: 593-000-003
Weil-McLain
SKU: 593-000-003
Brand: Weil-McLain
$50.68 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Wiring Harness - Control Module to Junction Box, 591-391-891
$37.35 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Natural Gas to Propane Gas Conversion Kit for GV Boilers (GV-5), 510-811-610
$90.35 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of Adapter 3" AL29-4C Vent Strt STVent , 560-907-724
$237.94 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of 7/16" x 14" Tie Rod Without Nut for GV-4 Boilers, 560-234-525
$12.03 each
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Backorder
Get it by Mon, Dec 21 - Fri, Jan 22
Compare
Product Image of 1" Copper Return Bend, 560-742-938
1" Copper Return Bend, 560-742-938
SKU: 560-742-938
Weil-McLain
SKU: 560-742-938
Brand: Weil-McLain
$121.95 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of Kit-C NG/LP GV90+ 6, 510-811-929
Kit-C NG/LP GV90+ 6, 510-811-929
SKU: 510-811-929
Weil-McLain
SKU: 510-811-929
Brand: Weil-McLain
$51.27 each
In Stock
Get 1 by Tue, Nov 24
In Stock
Get 1 by Tue, Nov 24
Resources
FAQs, Manuals & Videos
Articles
More About Weil McLain GV Boiler Parts

Weil McLain GV Boiler Parts cover the individual components that keep a GV series cast iron gas boiler running, from heat exchanger sections and gaskets to gas valves, igniters, and blower assemblies. The current GV90+ platform pairs cast iron heat exchanger sections with a condensing stainless steel secondary heat exchanger, and Weil-McLain rates the series above 91 percent AFUE, which exceeds ENERGY STAR requirements. Technicians servicing these boilers need parts that match the specific model and section count, since a smaller GV90+3 and a larger GV90+6 share the same overall design but use different section stacks. Sealed combustion venting on the GV90+ series also means replacement venting components and section gaskets have to hold an airtight seal to keep the boiler drawing combustion air the way it was designed to. Stocking the right Weil McLain GV parts keeps a service call a single visit instead of a return trip for a part that does not fit the installed model.

Subcategories

  • Heat Exchanger Sections & Gaskets: The heat exchanger is the core of the GV90+ design, built from cast iron primary sections paired with a condensing stainless steel secondary section. Gaskets seal the joints between sections and have to match both the section profile and the specific model's section count. A technician replacing a cracked section needs to confirm the exact model and section position before ordering, since sections toward the front and back of a stack are not always identical.
  • Gas Valves & Ignition Controls: Gas valves and ignition controls regulate fuel flow and manage the ignition sequence on startup, and the GV90+ series supports natural gas with a propane conversion kit for jobs that need it. A failed ignition control is one of the more common service calls on these boilers, and a replacement needs to match the boiler's fuel configuration, natural gas or converted propane, to fire correctly.
  • Blower & Venting Components: The GV90+ series vents through 3 inch PVC with direct vent, direct exhaust, and concentric venting options, and the blower moves combustion air through that sealed path. Because the system relies on sealed combustion, a worn blower or a venting component that no longer seals tightly can throw the boiler's combustion air balance off enough to trigger a safety lockout. Replacing these parts with the correct fit keeps the sealed combustion path intact rather than leaving a gap for air infiltration.
  • Circulators & Zone Relays: Circulators move heated water out to the distribution system, and zone relays coordinate which zones call for heat and when. A GV90+ installation split across multiple heating zones depends on its relay board functioning correctly to sequence circulators, so a relay replacement needs to match the zone panel already installed rather than being swapped in as a generic part.
  • Buying Guide

    Identifying the exact Weil McLain GV model is the first step before ordering any part, since the GV90+ series spans several sizes, from the GV90+3 up through the GV90+6, and section counts, gaskets, and some controls differ across that range even though the boilers look similar from the outside.

    Heat exchanger sections and gaskets need the closest attention to fit, because a section toward the front or back of the stack is not always interchangeable with a middle section on the same model. Ordering by section position as well as model number avoids a part that looks right but will not seal properly once installed.

    Gas valve and ignition control selection depends on the fuel the boiler is set up to burn. A unit converted from natural gas to propane using the factory kit needs ignition and gas valve components rated for that conversion, not the standard natural gas parts.

    Blower and venting parts matter because the GV90+ platform depends on sealed combustion through 3 inch PVC venting. A worn blower or a gasket that no longer seals on a vent connection can affect the boiler's combustion air balance, so these parts are worth replacing at the first sign of wear rather than waiting for a full failure.

    Zoned installations add one more consideration: circulators and relays need to match the zone control panel already in place. A Weil McLain GV boiler feeding several zones depends on that relay board sequencing correctly, so swapping in a generic relay without confirming compatibility can leave a zone unresponsive.

    Frequently Asked Questions

    How do I know which Weil McLain GV parts fit my boiler?

    Start with the model number on the boiler's data plate, since the GV90+ series spans several sizes and section counts, gaskets, and some controls are not interchangeable across models.

    What is the efficiency rating of the Weil McLain GV90+ series?

    The GV90+ series is rated above 91 percent AFUE and is certified to exceed ENERGY STAR efficiency requirements.

    Can a Weil McLain GV90+ boiler run on propane?

    Yes, the GV90+ ships set up for natural gas but includes a propane conversion kit, and ignition and gas valve parts need to match whichever fuel the boiler is configured for.

    Why would a GV90+ boiler go into a safety lockout related to venting?

    The GV90+ relies on sealed combustion through its venting system, so a worn blower or a vent gasket that no longer seals tightly can throw off the combustion air balance enough to trigger a lockout.

    Do heat exchanger sections need to match a specific position in the stack?

    Yes, sections toward the front or back of a GV90+ heat exchanger stack are not always identical to middle sections, so a replacement should be ordered by section position as well as model number.

Didn't find what you're looking for? 
Let us know
.