Apply to be a TradeMaster!
Filter menu expanded

Filters

470,476 items
Reset

SORT

Wilo Top S Pump Parts

Help Face
Need a little help?
470476 items
Grid
List
Compare
Product Image of 5/8"x 7/8"odf R22 10 Ton Thermal Expansion Valve, 124289
$590.15 each
In Stock
Get 2 by Tue, Dec 1
In Stock
Get 2 by Tue, Dec 1
Compare
Product Image of OVE-15-CP100 5/8" x 1-1/8" TXV, 124298
$596.17 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 7/8" X 1-3/8" Odf R22 15 Ton Thermal Expansion Valve, 124370
$590.15 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 1-1/8" X 1 3/8"odf R22 30 Ton Thermal Expansion Valve, 124540
$731.84 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 7/8" x 1 3/8" ODF R-404A 12 Ton TXV, 125216
$736.99 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Relay, 1253024-ESP
Relay, 1253024-ESP
SKU: 1253024-ESP
Embraco
SKU: 1253024-ESP
Brand: Embraco
$39.15 each
In Stock
Get 4 by Tue, Dec 1
In Stock
Get 4 by Tue, Dec 1
Compare
Product Image of 1-1/8"odf 35 Ton R410a Thermal Expansion Valve, 125369
$579.39 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 1-1/8" x 1-1/8" R-410A 20 Ton TXV, 125415
$636.71 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 7/8" X 1-1/8" Odf R410a 20 Ton Thermal Expansion Valve, 125478
$696.51 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 0-5/0-10 Vdc/4-20Ma 10K Thermistor, 125582
$221.79 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 7 X 8" X 1-1/8" R410a 25 Ton Thermal Expansion Valve, 125710
$625.96 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Pl Mounting Mounting All Blower, 12578
$250.05 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Commercial Condenser Fan Motor - 1/2 hp , 600 Rpm, 3 Ph, 208-230/460 V, 56 Frame, Oao, 1260-US-MOTORS
$835.57 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 5/8" X 7/8" R-22 11 Ton Thermal Expansion Valve, 5'cap, 126366
$1,738.59 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 5/8"x1-1/8"odf R22 11 Ton Thermal Expansion Valve, 126422
$1,798.02 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 1/6 hp , 1550, 48yz, Cx Motor, 1265
$414.44 each
In Stock
Get 14 by Tue, Dec 1
In Stock
Get 14 by Tue, Dec 1
Compare
Product Image of End Bell, 12776501
End Bell, 12776501
SKU: 12776501
Century
SKU: 12776501
Brand: Century
$85.43 each
In Stock
Get 1 by Mon, Nov 30
In Stock
Get 1 by Mon, Nov 30
Compare
Product Image of Fuse Time Delay 0.5A 600V , 127977P7S
Fuse Time Delay 0.5A 600V , 127977P7S
SKU: 127977P7S
Liebert
SKU: 127977P7S
Brand: Liebert
$83.87 each
In Stock
Get 5 by Tue, Dec 1
In Stock
Get 5 by Tue, Dec 1
Compare
Product Image of Electric Motor - 2 HP, 1750 RPM, 180V, TEFC, 128010.00
$2,054.78 each
In Stock
Get 5 by Mon, Nov 30
In Stock
Get 5 by Mon, Nov 30
Compare
Product Image of 1/2"x 7/8"odf R404a 3 Ton Thermal Expansion Valve, 128112
$675.91 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 45/5 MFD Oval Run Capacitor (440V)
45/5 MFD Oval Run Capacitor (440V)
SKU: 12890
Jard
SKU: 12890
Brand: Jard
$16.12 each
In Stock
Get 45 by Tue, Dec 1
In Stock
Get 45 by Tue, Dec 1
Compare
Product Image of 1" Threaded Housing Flange Kit for CEX Models
1" Threaded Housing Flange Kit for CEX Models
SKU: 129-168-1
Fireye
SKU: 129-168-1
Brand: Fireye
$276.00 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 1/2"x5/8"odf R404a 4 Ton Thermal Expansion Valve, 129003
$365.52 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Inverter PCB Assembly, 129040J
Inverter PCB Assembly, 129040J
SKU: 129040J
Daikin
SKU: 129040J
Brand: Daikin
$139.33 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Wrought Iron Escutcheon, 129102wr
Wrought Iron Escutcheon, 129102wr
SKU: 129102WR
Moen
SKU: 129102WR
Brand: Moen
$66.67 each
In Stock
Get 1 by Mon, Nov 30
In Stock
Get 1 by Mon, Nov 30
Compare
Product Image of 5/8" x 7/8" ODF R-407C 5 Ton TXV, 129109
$432.64 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 3/8"x 7/8"odf R22 8 Ton Thermal Expansion Valve, 129312
$411.23 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 5/8"x1-1/8"odf R22 10 Ton Thermal Expansion Valve, 129390
$411.23 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 1/2" x 5/8" ODF R-22 1.5 Ton TXV, 129523
$432.64 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 1/2x5/8 R-22 3 Ton Thermal Expansion Valve, 5'cap, 129642
$411.23 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 7 Tube Heat Exchanger, 12K79
7 Tube Heat Exchanger, 12K79
SKU: 12K79
Lennox
SKU: 12K79
Brand: Lennox
$1,581.52 each
In Stock
Get 1 by Fri, Dec 4 - Wed, Dec 9
In Stock
Get 1 by Fri, Dec 4 - Wed, Dec 9
Compare
Product Image of Blower Housing & Wheel 10" X 8", 12L16
$614.28 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 1/4hp 240v Blower Motor, 12W65
1/4hp 240v Blower Motor, 12W65
SKU: 12W65
Lennox
SKU: 12W65
Brand: Lennox
$329.86 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 208-230v 4.5 Ton 3ph R410a, 12Y44
208-230v 4.5 Ton 3ph R410a, 12Y44
SKU: 12Y44
Lennox
SKU: 12Y44
Brand: Lennox
$1,334.85 each
In Stock
Get 12 by Fri, Dec 4 - Wed, Dec 9
In Stock
Get 12 by Fri, Dec 4 - Wed, Dec 9
Compare
Product Image of Combustion Solenoid Valve Kit, 13-338
$214.97 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of 0-5/0-10 VDC/4-20mA 10k Thermistor, 130772
$200.45 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Single-Gang, Double-Face Electrical Outlet Box, 1311-BAF
$128.95 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 3 Hp 1740 Rpm 115/230V 184 Motor, 131534.00
3 Hp 1740 Rpm 115/230V 184 Motor, 131534.00
SKU: 131534.00
Leeson
SKU: 131534.00
Brand: Leeson
$909.21 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Electric Motor - 2 HP, 1740 RPM, DP, 131535.00
$576.19 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 208-230V1 Ph 5 Hp 1740 Rpm Motor, 131537.00
208-230V1 Ph 5 Hp 1740 Rpm Motor, 131537.00
SKU: 131537.00
Leeson
SKU: 131537.00
Brand: Leeson
$1,366.78 each
In Stock
Get 1 by Fri, Dec 4 - Wed, Dec 9
In Stock
Get 1 by Fri, Dec 4 - Wed, Dec 9
Compare
Product Image of Electric Motor - 3 HP, 1740 RPM, TEFC, 131545.00
$930.37 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Electric Motor - 5 HP, 1800 RPM, 131630.00
Electric Motor - 5 HP, 1800 RPM, 131630.00
SKU: 131630.00
Leeson
SKU: 131630.00
Brand: Leeson
$738.89 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Electric Motor - 3 HP, 3500 RPM, TEFC, 131637.00
$899.14 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 5-7 hp 3450 Rpm 182tz Dpao 1ph Motor, 131847
$894.15 each
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Compare
Product Image of Electric Motor - 7 HP, 3450 RPM, 230V, DP, 131847.00
$970.03 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 5 hp 3515 rpm 184t Tefc 3ph Epoxy Washdown Motor, 132202-LEESON
$1,395.73 each
In Stock
Get 1 by Thu, Dec 3
In Stock
Get 1 by Thu, Dec 3
Compare
Product Image of 0-5 Vdc In 0-15 Psi Out Valve, 133044
$258.85 each
In Stock
Get 1 by Tue, Dec 1
In Stock
Get 1 by Tue, Dec 1
Compare
Product Image of Universal Cube Diverter Tub Spout, 13307000
Universal Cube Diverter Tub Spout, 13307000
SKU: 13307000
Grohe
SKU: 13307000
Brand: Grohe
$256.70 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Top S Pump Parts

Wilo Top S pump parts keep the Wilo Top S line of hydronic circulator pumps running in residential and light commercial heating and cooling systems. Wilo Top S circulators move hot or chilled water through hydronic piping in boiler, radiant, and fan coil applications, and replacement parts extend the service life of pumps already installed in the field. Common parts include motor cartridges, seal kits, gaskets, and control modules that wear or fail well before the pump housing itself needs replacement. Technicians servicing a Wilo Top S pump typically diagnose whether the issue is electrical, mechanical, or related to a worn wet end before ordering parts. Stocking the right cartridge and seal combination for a given pump size shortens repair time on a callback. Sourcing genuine Wilo replacement parts helps maintain the pump's original flow and efficiency performance rather than settling for a full pump swap.

Subcategories

  • Motor Cartridges: Motor cartridges contain the wet-rotor motor assembly that drives the pump impeller. Technicians replace a cartridge when the motor windings fail or bearings wear out, since the cartridge can typically be swapped without removing the pump body from the piping. Matching cartridge voltage and pump size to the installed housing is essential for proper fit. Replacing the cartridge alone is usually faster and less disruptive than replacing the entire pump.
  • Seal and Gasket Kits: Seal and gasket kits address leaks at the pump housing and cartridge interface, a common failure point in circulators that run continuously through a heating season. Technicians inspect for mineral buildup or a hardened gasket before assuming the pump body itself is damaged. Replacing seals proactively during scheduled maintenance can prevent a leak from becoming a no-heat emergency call. Kits are sized to match specific Wilo Top S pump models.
  • Control Modules: Control modules on variable-speed Wilo Top S pumps manage speed settings and communicate operating status. A failed module often causes the pump to run at a fixed speed or stop responding to system demand. Technicians troubleshoot wiring and power supply before replacing a module outright. Choosing the correct module version for the pump's control type avoids compatibility issues.
  • Flanges and Mounting Hardware: Flanges and mounting hardware connect the Wilo Top S pump body to the system piping and support proper alignment. Worn or corroded flange gaskets are a frequent source of slow leaks around the pump connection points. Technicians replace flange hardware during a full pump service to prevent recurring leaks. Correct flange sizing keeps the pump properly aligned with existing piping runs.
  • Buying Guide

    Ordering the correct Wilo Top S pump parts starts with confirming the exact pump model and voltage printed on the unit's nameplate, since cartridges and control modules are not interchangeable across the full Top S lineup. Technicians should determine whether the pump uses a fixed-speed or variable-speed motor cartridge before ordering a replacement, since installing the wrong type can leave the system without proper speed control. When a pump is leaking, checking whether the failure is at the seal, the gasket, or a cracked housing helps determine whether a seal kit will resolve the issue or a full cartridge or pump replacement is needed. For control modules, confirming the communication protocol the building automation system expects prevents a mismatch between the new module and existing controls. Contractors stocking Wilo Top S pump parts for commercial service routes often keep cartridges and seal kits on hand for the pump sizes most common in their service area, since hydronic systems can fail without much warning during cold weather. Reviewing the pump's original installation documentation, when available, helps confirm the exact part numbers needed and reduces the chance of ordering an incompatible component. Replacing worn parts on a Wilo Top S pump promptly, rather than waiting for a full failure, typically costs less in labor than an emergency pump swap during peak heating season.

    Frequently Asked Questions

    Can a Wilo Top S motor cartridge be replaced without draining the whole system?

    Most Wilo Top S pumps allow the cartridge to be removed while isolating the pump with flange-mounted isolation valves, limiting water loss to the pump body itself. Systems without isolation valves will require draining before cartridge replacement. Checking for isolation valves ahead of the service call helps technicians plan the repair more efficiently.

    What typically causes a Wilo Top S pump to run noisy?

    Noise often points to air trapped in the system, a worn bearing inside the motor cartridge, or debris caught in the impeller. Bleeding air from the system is usually the first troubleshooting step before replacing any parts. Persistent grinding or humming after bleeding usually indicates a cartridge replacement is needed.

    How do I identify the correct replacement seal kit for a Wilo Top S pump?

    The pump's model number and size, found on the nameplate, determine the correct seal kit, since kits vary by pump body size. Technicians should record this information before removing the pump for service. Ordering by nameplate model number avoids fit issues with the wrong kit.

    Why would a variable-speed Wilo Top S pump stop responding to a building automation system?

    A failed or disconnected control module is a common cause, along with wiring faults at the communication terminals. Technicians should verify power and signal wiring before replacing the module. Confirming the module's communication protocol matches the automation system prevents recurring issues after replacement.

    Is it possible to upgrade a fixed-speed Wilo Top S pump to variable-speed using replacement parts?

    Fixed-speed and variable-speed Wilo Top S pumps use different motor cartridges and control architectures, so an upgrade generally requires a cartridge designed for variable-speed operation along with a compatible control module. Confirming the pump housing supports the variable-speed cartridge is an important step before ordering parts. Contractors should check manufacturer documentation to confirm compatibility before attempting the upgrade.