Apply to be a TradeMaster!
Filter menu expanded

Filters

471,048 items
Reset

SORT

Wilo Z-15 Pump Parts

Help Face
Need a little help?
471048 items
Grid
List
Compare
Product Image of 50HCD085A Parts -WeatherMaker 7.5 Ton Packaged Rooftop High Efficiency Cool Only & Electric Heat Unit 2-stage (208/230-3-60)not-to-sell-product
50HCD085A Parts -WeatherMaker 7.5 Ton Packaged Rooftop High Efficiency Cool Only & Electric Heat Unit 2-stage (208/230-3-60)
SKU: 50HCD085A
Carrier
SKU: 50HCD085A
Brand: Carrier
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Blower Panel Assembly, 50ZP400436
Blower Panel Assembly, 50ZP400436
SKU: 50ZP400436
Carrier
SKU: 50ZP400436
Brand: Carrier
$234.66 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Insulation Assembly Compr Supply 42", 50ZP400732
$191.32 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Coil Evap Al/Cu, 50ZP401010
Coil Evap Al/Cu, 50ZP401010
SKU: 50ZP401010
Carrier
SKU: 50ZP401010
Brand: Carrier
$2,849.20 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Partition Coil 30", 50ZP500670
Partition Coil 30", 50ZP500670
SKU: 50ZP500670
Carrier
SKU: 50ZP500670
Brand: Carrier
$32.08 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50ZPC04230 Parts -Comfort 3.5 Ton 14 SEER Residential Packaged Air Conditioning Unit (Tin-Plated Coil)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Panel, 50ZZ500483
Panel, 50ZZ500483
SKU: 50ZZ500483
Carrier
SKU: 50ZZ500483
Brand: Carrier
$415.83 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50PCV030EA Parts -Aquazone 2.5 Ton Compact Water Source Heat Pump s Vertical Upflow Left Return (208/230-1-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50PCV0365A Parts -Aquazone 3 Ton Compact Water Source Heat Pump s Vertical Upflow Left Return (208/230-1-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50HCQD08---6A Parts -WeatherMaster - 7.5 Ton High Efficiency Cooling Only/Electric Heat Packaged Rooftop .not-to-sell-product
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 50PCV060601 Parts -Aquazone 5 Ton Compact Water Source Heat Pump s Vertical Right Return (208/230-1-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50PCV0703A Parts -Aquazone 6 Ton Compact Water Source Heat Pump s Vertical Upflow Left Return (208/230-1-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Coil Evap Tin Plated, 50SD400354
Coil Evap Tin Plated, 50SD400354
SKU: 50SD400354
Carrier
SKU: 50SD400354
Brand: Carrier
$1,707.95 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Insulation Assembly Fan Deck, 50HE401530
Insulation Assembly Fan Deck, 50HE401530
SKU: 50HE401530
Carrier
SKU: 50HE401530
Brand: Carrier
$843.07 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Coil Condenser Al/Cu, 50HE401851
Coil Condenser Al/Cu, 50HE401851
SKU: 50HE401851
Carrier
SKU: 50HE401851
Brand: Carrier
$4,594.70 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Coil Evaporator Al/Cu, 50HE402702
Coil Evaporator Al/Cu, 50HE402702
SKU: 50HE402702
Carrier
SKU: 50HE402702
Brand: Carrier
$11,485.27 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Coil Reheat Al/Cu, 50HE403110
Coil Reheat Al/Cu, 50HE403110
SKU: 50HE403110
Carrier
SKU: 50HE403110
Brand: Carrier
$3,111.18 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Coil Evaporator Al/Cu, 50HE403112
Coil Evaporator Al/Cu, 50HE403112
SKU: 50HE403112
Carrier
SKU: 50HE403112
Brand: Carrier
$11,451.22 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Coil Evaporator Aluminum & Copper, 50HE403224
Coil Evaporator Aluminum & Copper, 50HE403224
SKU: 50HE403224
Carrier
SKU: 50HE403224
Brand: Carrier
$11,496.10 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of Motor Channel, 50HE500274
Motor Channel, 50HE500274
SKU: 50HE500274
Carrier
SKU: 50HE500274
Brand: Carrier
$230.13 each
In Stock
Get 5 by Wed, Dec 2
In Stock
Get 5 by Wed, Dec 2
Compare
Product Image of Retainer(Panel Insulation), 50SS501020
Retainer(Panel Insulation), 50SS501020
SKU: 50SS501020
Carrier
SKU: 50SS501020
Brand: Carrier
$36.40 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Wire Harness, 50HEHMRARC-A00
Wire Harness, 50HEHMRARC-A00
SKU: 50HEHMRARC-A00
Carrier
SKU: 50HEHMRARC-A00
Brand: Carrier
$610.52 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Harness Compressor Power, 50HEHMRSA-500
Harness Compressor Power, 50HEHMRSA-500
SKU: 50HEHMRSA-500
Carrier
SKU: 50HEHMRSA-500
Brand: Carrier
$677.93 each
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50TCQD09---1A Parts -WeatherMaker 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Precoat Coil (208/230-3-60)not-to-sell-product
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 50TCQD09---5A Parts -WeatherMaker 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Precoat Coil (208/230-3-60)not-to-sell-product
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 50TCQD09---6A Parts -WeatherMaker 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Precoat Coil (208/230-3-60)not-to-sell-product
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 50TCQD091A Parts -WeatherMaker 8.5 Ton Packaged Rooftop Heat Pump Unit 2-Stage Med. Static (208/230-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50TCQD096A Parts -WeatherMaker 8.5 Ton Packaged Rooftop Heat Pump Unit 2-Stage Med. Static (208/230-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50T-65FB-3N-PRE-NAECA Parts - 50T Light Duty Energy Saver Water Heater, NG (Pre NAECA)not-to-sell-product
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 50TC-D09---9A Parts -WeatherMaker 8.5 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Precoat Coil (208/230-3-60)not-to-sell-product
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 50HC-D28 7 6A Parts - Carrier Single Package Rooftop Electric Cooling Unitnot-to-sell-product
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 50HC-D28 B 5A Parts - Carrier Single Package Rooftop Electric Cooling Unitnot-to-sell-product
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 50HCA046A Parts -WeatherMaster 3 Ton Packaged Rooftop High Efficiency Cool Only & Electric Heat Pre-coated Coil (208/230-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50HCA051A Parts -WeatherMaster 4 Ton Packaged Rooftop High Efficiency Cool Only & Electric Heat Unit (460-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50HCA075A Parts -WeatherMaster 6 Ton Packaged Rooftop High Efficiency Cool Only & Electric Heat Pre-coated Coil(208/230-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50FC-A04A2M5-0F2C0 Parts - Carrier Weathermaker Elec/Electric Rooftopnot-to-sell-product
50FC-A04A2M5-0F2C0 Parts - Carrier Weathermaker Elec/Electric Rooftop
SKU: 50FC-A04A2M5-0F2C0
Carrier
SKU: 50FC-A04A2M5-0F2C0
Brand: Carrier
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 50FC-A05A2A1-0F0 Parts - Carrier Single Package Rooftop Entry Heat Pump System Viewnot-to-sell-product
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 50TCQD125A Parts -WeatherMaker 10 Ton Packaged Rooftop Heat Pump Unit , 2-Stage, Med. Static, Precoat Coil (460-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50TCQD1766A Parts -WeatherMaker 15 Ton Standard Efficiency Cooling Only/Electric Heat Packaged Rooftopnot-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50TCQD2411A Parts -WeatherMaker 20 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Vertical (208/230-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50TCQD2436A Parts -WeatherMaker 20 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Vertical (208/230-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50TC-D24---6A Parts -WeatherMaker - 20 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Vertical (460-3-60)not-to-sell-product
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Compare
Product Image of 50HCQD126A Parts -WeatherMaster 10 Ton Packaged Rooftop High Efficiency Cool Only & Electric Heat Unit (208/230-3-60)not-to-sell-product
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of 50FC-M07A2A6-0A0 Parts - Carrier Single Package Rooftop Entry Cooling Onlynot-to-sell-product
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 50FC-M08A2A6-0A0 Parts - Carrier Packaged Rooftop Electric Cooling Unitsnot-to-sell-product
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 50FC-M12A3M6-3U5F0 Parts - Carrier Weathermaker Elec/Electric Rooftopnot-to-sell-product
50FC-M12A3M6-3U5F0 Parts - Carrier Weathermaker Elec/Electric Rooftop
SKU: 50FC-M12A3M6-3U5F0
Carrier
SKU: 50FC-M12A3M6-3U5F0
Brand: Carrier
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Backorder
Get it by Mon, Mar 1 - Mon, May 24
Compare
Product Image of 50TCQD2471A Parts -WeatherMaker 20 Ton Packaged Rooftop Cooling Only & Electric Heat Unit 2-Stage Vertical (208/230-3-60)not-to-sell-product
VIEW REPLACEMENT PARTS
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Backorder
Get it by Mon, Jan 4 - Mon, Feb 1
Compare
Product Image of Heat Exchanger Assembly, 50TG402856
Heat Exchanger Assembly, 50TG402856
SKU: 50TG402856
Carrier
SKU: 50TG402856
Brand: Carrier
$3,242.66 each
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Backorder
Get it by Tue, Jan 5 - Thu, Feb 4
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Z-15 Pump Parts

Wilo Z-15 pump parts are the replacement components contractors use to service and rebuild Z-15 wet-rotor circulator pumps found in residential and light commercial hydronic heating and hot water recirculation systems. The Z-15 is a single-speed, in-line circulator, and its most commonly replaced parts are the pump head, rotor and impeller assembly, and the mounting gaskets that seal the pump body to the piping flanges. Over years of continuous operation, mineral buildup and worn bearings inside the wet-rotor cartridge are the usual reasons a Z-15 needs a rebuild rather than a full replacement. Keeping gaskets, cartridges, and mounting hardware on hand lets a contractor return a system to service the same day instead of waiting on a full pump swap, which matters most on boiler systems where extended downtime affects a building's heat.

Subcategories

  • Pump Heads: Pump heads house the motor and electrical connections for the Z-15 circulator and bolt directly onto the wet-rotor cartridge below. Contractors replace a pump head when the motor windings fail or a bad capacitor stops the rotor from starting, rather than swapping the entire unit. Because the head separates from the wet end without draining the whole system in most installations, it's often the fastest single-part repair on a Z-15. Matching the voltage and speed rating to the original nameplate keeps the replacement head compatible with the existing wiring.
  • Rotor & Impeller Assemblies: The rotor and impeller assembly is the wet-rotor cartridge that spins inside the pump body to move water through the system. Mineral scale and sediment are the most common causes of a sluggish or seized rotor, especially in older cast iron hydronic loops. Replacing the assembly restores full flow without needing to replace the pump housing or motor head. A worn sleeve bearing inside the assembly is usually what causes the humming or grinding noise contractors hear before a Z-15 fails outright.
  • Mounting Gaskets & Flanges: Mounting gaskets seal the pump body against the flanges that connect it to the supply and return piping. A worn or improperly seated gasket is one of the most common sources of a slow weep leak at the pump union. Flanges themselves rarely need replacement unless they've been damaged during a prior installation or corroded from years of exposure to boiler water. Keeping the correct gasket size on hand avoids a return trip when a routine pump service uncovers a leak at the union.
  • Cartridge Seal Kits: Cartridge seal kits bundle the O-rings and shaft seals needed to reseal the wet-rotor cartridge after it's opened for cleaning or bearing replacement. Using a complete kit instead of individual seals reduces the chance of missing a small O-ring that causes a repeat callback. Seal kits are typically sized to the specific cartridge generation, so matching the kit to the pump's production era matters more than matching it to the overall Z-15 model name alone. A fresh seal kit is standard practice any time the cartridge is removed for service, even if the old seals look intact.
  • Buying Guide

    When sourcing Wilo Z-15 pump parts, start with the failure symptom rather than guessing at a full parts list. A pump that hums but doesn't spin usually points to a seized rotor or worn bearing, calling for a rotor and impeller assembly rather than a new pump head. A pump that won't start electrically, or trips a breaker, more often points to the motor windings or capacitor inside the pump head itself. Confirm the exact age and cartridge generation of the installed unit before ordering, since Wilo has updated the internal cartridge design over the years and parts from a newer cartridge don't always fit an older pump body. For jobs where the pump has been in continuous service for many years, rebuilding with a full cartridge seal kit alongside the rotor assembly is often more efficient than replacing components piecemeal, since it addresses wear across the whole wet end in one visit. Keep a small stock of the most commonly needed Wilo Z-15 pump parts, gaskets, seal kits, and a spare pump head, on hand for routine hydronic service calls, since these are the components most likely to fail from years of continuous operation. For a pump that's failed catastrophically or is several rebuilds in already, replacing the entire unit is often the more practical long-term choice over continuing to source individual parts.

    Frequently Asked Questions

    How do I know if my Wilo Z-15 needs a new pump head or a full rotor assembly?

    If the pump is silent and doesn't spin at all, check the motor head first, since that usually points to a failed capacitor or burned winding. If the pump hums or vibrates but the rotor won't turn, the wet-rotor cartridge itself is more likely the problem. Testing continuity at the motor terminals before ordering parts helps confirm which component actually failed.

    Can I rebuild a Z-15 without draining the whole heating system?

    In most installations, the pump head separates from the wet-rotor cartridge without opening the main piping, so a motor swap doesn't require draining the loop. Replacing the cartridge, gaskets, or flanges does require isolating and draining the pump section, though the rest of the system can often stay filled if isolation valves are present. Always confirm the specific installation has isolation valves before promising a no-drain repair.

    Why does my Z-15 keep leaking at the union even after a new gasket?

    A repeat leak after a gasket replacement is usually a sign the flange itself is corroded, warped, or wasn't torqued evenly during installation. Overtightening a new gasket can also distort it and cause the same leak to return. Checking the flange surface for pitting and torquing bolts in a cross pattern typically resolves a recurring union leak.

    How long does a Z-15 cartridge seal kit typically last?

    Seal life depends heavily on water quality and how often the system cycles, so there's no single fixed interval for every installation. Systems with harder water or more mineral content tend to wear seals faster than closed loops with treated water. Replacing the seal kit any time the cartridge is opened for service, rather than waiting for a visible leak, helps avoid a repeat callback.

    Is it worth rebuilding an older Z-15 or should I replace the whole pump?

    A rebuild makes sense when the pump body and flanges are still in good condition and only the wet-rotor cartridge or motor head has failed. Once a pump has needed several rebuilds over a short period, or the housing itself shows corrosion, replacing the entire unit is usually the more practical option. Weighing the age of the installation against the parts already on hand helps make that call quickly during a service visit.